When determination of the result based on measurement
result by operator is input, the result is displayed in output
window as shown below.
When Normal
Measurement value PASS
When Abnormal
Measurement value FAIL
Troubleshooting
If FAIL, check parts (DSP circuit board: TR707 - TR711)
and peripheral circuitry and wire connection.

3-6. SWITCH inspection

Inspect on | off status of FRONT LED DISABLE switch.
Inspect FOH / MAIN | OFF | MONITOR status
D-CONTOUR switch.
Inspect 120 Hz | 100 Hz | OFF status of HPF switch.
Set status of each switch according to the display and click
"OK" button.
If result is FAIL, the following display for retry is dis-
played.
When "Retry" button is clicked, the test is performed
again.
When "Cancel" button is clicked, the test is not performed
again.
PASS: LINK-MUTE LEVEL
FAIL: LINK-MUTE LEVEL
オペレータの計測結果に応じた結果判定を入力する
と、検査結果はアウトプット ウインドウへ下記のよ
うに表示されます。
正常時
計測値 PASS
PASS:LINK-MUTE LEVEL
異常時
FAIL:LINK-MUTE LEVEL
計測値 FAIL
トラブルシューティング
FAIL の場合、DSP シート上の TR707 ∼ TR711 と周
辺の部品および配線を確認してください。
3-6. SWITCH 検査
FRONT LED DISABLE スイッチの ON | OFF 状態を
検査します。
D-CONTOUR ス イ ッ チ の FOH / MAIN | OFF |
MONITOR 状態を検査します。
HPF スイッチの 120 Hz | 100 Hz | OFF 状態を検査し
ます。
画面表示に従って各スイッチの状態を設定し、 「OK」
ボタンをクリックします。
FAIL の場合、下記の再検査用画面が表示されます。
「Retry」ボタンをクリックすると再テストが実施さ
れます。
「Cancel」ボタンをクリックすると再テストは実施
されません。