1 • GENERAL REMINDERS • The oven must be installed, commissioned • Example of a data plate: and maintained only by an authorized service agent. LOGO • Carefully read the directions given in this TYP. XXXXXXXX manual; they contain important information 2008 NR XXXXXXXXXX on safety during installation, operation and...
3 • SPECIAL REQUIREMENTS FOR THE INSTALLATION SITE • The environment where the oven will be • A w a t e r d r a i n a g e s y s t e m m u s t b e installed must be well ventilated and in available in the room, positioned in the c o m p l i a n c e w i t h n a t i o n a l a n d l o c a l...
5 • POSITIONING • When positioning the appliance, it is • Once the appliance is installed, the recommended to use the stand suggested electrical power cable must be protected, by the manufacturer; if you decide and never stretched or tugged. differently, the weight of the appliance must be taken into consideration, along •...
6 • ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING 220-240Vac, 1P+N+E • As this oven is a type X appliance (oven (Only for EC40M5 / EC40D5) without power cable and plug), the cable and other hardware needed to make the connection to the electrical power Terminal block: supply must be provided by the installer.
6 • ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING • T h e o v e n m u s t a l s o b e b o n d e d • The electrical safety of this appliance can equipotentially to other equipment in be guaranteed only when it is connected the kitchen.
8 • WATER AND DRAIN CONNECTIONS 8.1 • WATER PRESSURE 8.4 • DRAIN The pressure of the water in the network It is imperative to fit a drain cup to ensure must be between 200 and 500 kPa, a minimum air drop of 25mm. between (30 - 72 psi) as already stated under the the appliance’s plastic drain elbow and heading “Table 2: General Water Data”.
10 • COMMISSIONING AND TESTING 10.1 • Check the appliance and the entire 10.2 • Now proceed to operate the oven as installation straight after connecting. directed in the user manual. Check in particular: • there are no traces of the protective film on 10.3 •...
12 • DISMANTLING AND DISPOSAL “Implementation of Directives 2002/95/ 12.2 • The user must therefore dispose of the E C , 2 0 0 2 / 9 6 / E C a n d 2 0 0 3 / 1 0 8 / E C equipment at the end of its useful life at r e l a t i n g t o t h e u s e o f h a z a r d o u s the appropriate centres for the separate...
13 • INSTALLATION DIAGRAMS DISTANCES TO BE ADHERED TO The appliance cannot be recessed. One of the two sides must be 500mm exposed. 20inch Minimum distance from wall: 50mm / 1.9 inches AVOID POSITIONING HEAT- RADIATING APPLIANCES ON EITHER SIDE OF THE OVEN ATTENTION: if the temperature on the sides of the appliance is excessively high, as a safety...
14 • REMOVING THE CONTROL PANEL (Version D) The following are the instructions for removing 14.2 • REPLACING THE CONTROL BOARD the control panel to replace the control board KEYPAD or the glass panel. Disconnect the control board keypad 14.1 • REMOVING THE CONTROL PANEL connector and the encoder connector.
Need help?
Do you have a question about the EC40 Series and is the answer not in the manual?
Questions and answers