3.2.3

Tone Sensitivity Specification

Tone sensitivity is dependent on various test conditions such as path losses, orientation of the unit,
type of source antenna, test equipment etc. A user may compare measurements to a known good
unit. +-2 dB variation in Tone sensitivity measurement is expected from unit to unit measured.
3.3

Test Mode

1. Rotate the Function Switch to position D.
2. Press and hold the Reset Button while powering on the unit.
3. An audible alert and red LED will indicate that you have entered to the I/O Test Mode.
Release the Reset Button.
4. Press the Reset Button, the red LED turns off and the amber LED turns on.
5. Press the Reset Button, the amber LED turns off and the Battery Indicator LED turns on red.
6. Press the Reset Button, the Battery Indicator LED turns green.
7. Press the Reset Button, all LEDs turn on, the Battery Indicator LED is amber.
8. Press the Reset Button, all LEDs turn off and unit enters Pulsed Vibrate Mode.
9. Press the Reset Button, the unit enters Constant Vibrate Mode.
10. Press the Reset Button, a high pitched tone is heard.
11. Press the Reset Button, a louder high pitched tone is heard.
12. Press the Reset Button, a high pitch tone is heard and unit enters Constant Vibrate Mode.
13. Press the Reset Button, the unit enters Open Squelch Mode.
14. To exit Test Mode, power off the unit.
Receive Performance Check: Test Mode