The Dranetz HDPQ® family of Power Quality, Demand and Energy instruments is the latest in a long line of industry
leading products from Dranetz. The Dranetz HDPQ family is comprised of four portable instruments, with the
difference being the availability of Wi-Fi communications, advanced intelligent AnswerModules, high speed transient
capabilities, 400Hz monitoring and other advanced features. The Dranetz HDPQ instruments are: Visa, Guide, Xplorer
and Xplorer-400. Each is a successor to the Dranetz PowerVisa, PowerGuide, PowerXplorer and PowerXplorer-400.
The Dranetz HDPQ merges the state-of-the-art power monitoring capabilities you expect from Dranetz, with 'best in
class' communication capabilities to provide users with a revolutionary monitoring experience. Each instrument has a
built-in 7-inch color wide screen LCD user interface for monitoring setup and data review. By putting operator safety
first, the Dranetz HDPQ also enables users to review data and change settings remotely from virtually any Smartphone
or Tablet mobile device, along with traditional PC and Mac laptops and desktops. Just hook up the instrument, close
the cabinet doors to 'safe' the environment and use either a free 3
Android App via Ethernet, Wireless, or Bluetooth for remote control from anywhere with connectivity to the
instrument.
Shop for Power Metering products online at:
®
HDPQ
DATA S
, X
-400, G
PLORER
UMMARY
P
Q
, D
OWER
UALITY
EMAND
W
,
LCD
IDE SCREEN COLOR
TOUCH
50/60H
, AC/DC
Z
VOLTAGE CHANNELS
, N
,
AVAL
MILITARY
T
. 1
(X
US
RANSIENTS
US
PLORER
FLEX
URRENT CHANNELS WITH
A, EN50160:2010
LASS
, S
, T
, U
WELL
RANSIENTS
NBALANCE
, I
, M
NTERHARMONICS
AINS
10K
(G
CYCLE RECORDING
®
A
M
(G
NSWER
ODULES
UIDE
-
USE WITH AUTOMATIC OR MANUAL SETUPS
FLASH
. E
MEMORY
XTERNAL STORAGE VIA
, 802.11 W
, B
IRELESS
LUETOOTH
A
, A
T
& S
PPLE
NDROID
ABLETS
C
F
PC, M
ONTROL
OR
AC
T
S
NTERNAL
IME
YNCHRONIZATION
D
V
7
OMPATIBLE WITH
RAN
IEW
IP50 E
NCLOSURE WITH EASEL
www.
HEET
& V
UIDE
& E
A
NERGY
NALYSIS
(X
-400)
PLORER
, X
-400)
PLORER
PROBE POWER
, G
)
PLORER
UIDE
, F
LICKER
S
IGNALING
, X
/400)
UIDE
PLORER
, X
/400)
PLORER
USB
, USB
OTG
MARTPHONES
, IOS & A
NDROID
&
CABLE MANAGEMENT
-
COUNTRY PLUGS
rd
party VNC App or our Dranetz HDPQ Apple or
PowerMeterStore
ISA
Dran-View® 7
77Compatible
1.800.561.8187
.ca
Apple &
Android Apps

Advertisement

loading
Need help?

Need help?

Do you have a question about the HDPQ XPLORER and is the answer not in the manual?

Questions and answers

Summary of Contents for Dranetz HDPQ XPLORER

  • Page 1 77Compatible NTRODUCTION The Dranetz HDPQ® family of Power Quality, Demand and Energy instruments is the latest in a long line of industry leading products from Dranetz. The Dranetz HDPQ family is comprised of four portable instruments, with the difference being the availability of Wi-Fi communications, advanced intelligent AnswerModules, high speed transient capabilities, 400Hz monitoring and other advanced features.
  • Page 2 HDPQ A RANETZ PPLICATIONS Voltage The Dranetz HDPQ family is a series of portable Dranetz HDPQ has (4) differential AC/DC voltage monitoring instruments that is intended for temporary channels rated 1000V CAT III/600V CAT IV. Voltage and semi-permanent Power Quality, Demand, and channels are labeled A, B, C, D and are connected to Energy surveys.
  • Page 3 HDPQ ACKAGING INSTRUMENTS Enclosure All Dranetz HDPQ instruments are packaged in an IP50, ergonomically designed ABS plastic enclosure with a All Dranetz HDPQ instruments have a built-in 7-inch protective rubber boot. The HDPQ enclosure provides (measured diagonally) color LCD touch display with an LED backlight.
  • Page 4 Dranetz HDPQ in a Dranetz remote control. Users download a free program or App weather resistant enclosure, or other enclosure. and connect remotely to the Dranetz HDPQ via an Ethernet, Wireless, or Bluetooth PAN network. VNC uses the Dranetz HDPQ’s remote communication...
  • Page 5 HDPQ IRING ONFIGURATIONS INSTRUMENTS All Dranetz HDPQ instruments can be connected to the following circuit types:  Single phase  Split Phase  3 Phase, Four Wire Wye  3 Phase Delta  3 Phase (Floating or Grounded) Delta ...
  • Page 6 Xplorer and Xplorer-400 having additional circuitry to also capture high speed transients. It is important to note that the Dranetz HDPQ goes well beyond the requirements of IEC 61000-4-30 and EN 50160. In addition, the Dranetz HDPQ family employs the methods used for voltage transients to trigger on current transients.
  • Page 7 200ms window without any gaps between waveform, and if the difference exceeds the user’s windows. Being Class A, the Dranetz HDPQ family fully limits, an event is recorded. In the picture below, the complies with these requirements.
  • Page 8 Power Quality, Demand and Energy analysis, and reporting software. Real-time Meters, Trends and Event Lists All parameters available in the Dranetz HDPQ can be metered in real-time, trended over time, and can have trigger conditions enabled to record details of changes in each parameter.
  • Page 9 The statistical package customers to easily share monitoring information, or called Quality of Supply (QOS) is built into the Dranetz sent to Dranetz Technical Support for assistance with HDPQ, with monitoring and setup protocols available...
  • Page 10 Enterprise, so there’s a version to meet everyone’s Power Factor, Demand (Active, VA, VAR), Energy (WHr, needs. VAHr, VARHr). The Dranetz HDPQ Xplorer and Xplorer- 400 add Forward and Reverse energy parameters. Like all Dranetz portable products, Dranetz HDPQ is directly compatible with Dran-View.
  • Page 11 Dranetz HDPQ Dimensions PowerMeterStore 1.800.561.8187 www. Shop for Power Metering products online at:...
  • Page 12: Pq Parameter Calculations

    PQ Parameter Calculations Measuring and monitoring power quality (PQ) parameters require several Calculations calculations, i.e. RMS values of voltage and current, etc. Depending on the type of parameter measured, calculations are performed using samples of monitored waveforms or using every sample cycle for quick disturbance detection.
  • Page 13 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision RMS Deviation Vcycw-a Single phase Volts +/- 0.2% of Vrms(cycle 1) - Vcycw-b Split phase Reading * Vrms(cycle 2) Subtraction of 1 Vcycw-c 15 KHz BW cycle RMS from Vcycw-d adjacent cycles. Vcycw-ab Measured for Delta Used for cyclic...
  • Page 14 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Volts RMS of Vfnd-a Single phase Volts +/- 0.2% of fundamental Vfnd-b Split phase Reading * Vfnd-c 15 KHz BW Derived from DFT Vfnd-d is calculated from Vfnd-ab Measured for Delta Vfnd-bc Calculated for Wye the 1...
  • Page 15 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Amps RMS Irms-a Amps +/- 0.1% of Derived from Irms-b Reading 200mS (10/12 Irms-c +/- 0.05% cycles 50/60 Hz) Irms-d of FS where n=512 samples Aggregated to 9 KHz BW selected interval Amp ½...
  • Page 16 Calculations (continued) Description Abbreviation Formula Wiring Configuration Units Precision Phase of Ideg-a Degree +/- 1° fundamental Ideg-b averaged over Ideg-c where n=1 for 1 har- 200ms. Ideg-d monic. Derived from DFT Averaged over 10/12 sine expansion cycles output. Phase of Icycdeg-a Degree +/- 1°...
  • Page 17 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Residual Current Ires Delta or Wye only Amps 0.3 % of RMS of Reading +/- 0.15% of FS where n=512 samples Net Current Inet Wye only Amps 0.4 % of RMS of Reading +/- 0.15% of FS...
  • Page 18 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision VA Arithmetic VAfa-tot Wye and Neutral based 0.2 % of Fundamental Total measurements Reading +/- 0.05% of FS True Power Factor TPF-a Wye, uses measured None 1% of values Reading TPF-b Not meaningful for TPF-c Delta...
  • Page 19 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Total Arithmetic DPFa-tot None +/- 1% Displacement Power Factor VA derived from DFT fundamenta Total Vector DPFv-tot None +/- 1% Displacement Power Factor VA derived from DFT fundamental Total Voltage HVthdfund-a +/- 5% Harmonic HVthdfund-b...
  • Page 20 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Total Voltage HVthdrss-a +/- 5% Harmonic HVthdrss-b Distortion Root HVthdrss-c Sum of Squares Per 61000-4-7 (RSS) HVthdrss-d HVthdrss-ab HVthdrss-bc HVthdrss-ca Total Voltage Inter HVtidrss-a +/- 5% Harmonic HVtidrss-b Distortion Root HigI is Voltage Inter- HVtidrss-c Sum of Squares harmonic Group...
  • Page 21 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Total Current HIehd-a +/- 5% Even Harmonic HIehd-b Distortion HIehd-c *100 Normalized to the fundamental HIehd-d Per 61000-4-7 Telephone HVtiffund-a None +/- 1% Influence Factor, HVtiffund-b normalized to HVtiffund-c TIF = Fundamental HVtiffund-d where:...
  • Page 22 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Total Harmonic Huspower-a Watts +/- 5% unsigned power Huspower-b Huspower-c Huspower-d Total Harmonic Hspower-a Watts +/- 5% signed power Hspower-b Hspower-c Hspower-d Transformer K HIxfmrk-a None +/- 5% Factor HIxfmrk-b HIxfmrk-c HIxfmrk-d Transformer De- HIxfmrdrat-a...
  • Page 23 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Volts Over- HVodev-a +/- 1% Deviation HVodev-b HVodev-c HVodev-d If result is < V then HVodev-ab value is 0 HVodev-bc HVodev-ca Where: is Declared Nominal Voltage is 200ms RMS Per 61000-4-30 User Specified Volts +/- .2 %...
  • Page 24 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Individual Inter Volts Volts +/- 5% Computed according Harmonic to 61000-4-7 using Voltages h:h+1 DFT over 200mS 0-127 window aggregated to h0=DC selected journal inter- val as RMS Individual Inter Current Amps +/- 5% Computed according...
  • Page 25 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Short Term Pst-a None +/- 5% Compliant to 61000- Flicker Pst-b 4-15 Pst-c Pst-ab Pst-bc Pst-ca Long Term Flicker Plt-a None +/- 5% Compliant to 61000- Plt-b 4-15 Plt-c Plt-ab Plt-bc Plt-ca Long Term Flicker PltSlide-a...
  • Page 26 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision VAR coincident VARcoW VAR Demand at time +/- 0.5% with Peak Watts of Peak Watts, during Demand a Demand interval Average True PFavgcoW None +/- 0.5% Average True PF at Power Factor time of Peak Watts, coincident with during a Demand...
  • Page 27 Calculations (continued) Description Abbreviation Wiring Configuration Formula Units Precision Energy Watt- WHr-a Sum of Watt readings Watt-h +/- 0.22% Hours each second scaled to WHr-b Watt-Hours and WHr-c accumulated into user WHr-d selected interval. WHr-tot Energy VAR- VARHr-a Sum of VAR readings VAR-h +/- 0.22% Hours each second scaled to...

This manual is also suitable for:

Hdpq xplorer-400Hdpq guideHdpq visa