Siemens Acuson S1000 Instructions For Use Manual page 500

Diagnostic ultrasound system
Table of Contents

Advertisement

A p p e n d i x F A c o u s t i c O u t p u t R e f e r e n c e
Acoustic Output Reporting Table — Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: MC9-4
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
@ max. I
P
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ max. MI
pa.3
max
pa,α
Focus (cm)
Frequency (MHz)
Res/Speed
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Acoustic Output Reporting Table — Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: MC9-4
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
P
@ max. I
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ max. MI
pa.3
max
pa,α
Focus (cm)
Res/Speed
Ensemble Size
Frequency (MHz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
F - 5 8
Operating mode: 2D-Mode (THI)
MI
Scan
1.31
0.88
Units
(MPa)
2.69
(mW)
44.41
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
1.54
pi,α
(cm)
(MHz)
4.18
4.18
X (cm)
1.83
Y (cm)
0.60
0.42
(µsec)
(Hz)
19.07
(MPa)
3.36
pi
(cm)
pi
(cm)
9.50
(cm)
2.00
2
(W/cm
)
341.89
1.50
9.50
0.00
0.00
0
4
Operating mode: Color / Power
MI
Scan
1.30
0.99
Units
(MPa)
3.19
(mW)
44.17
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
1.79
pi,α
(cm)
(MHz)
6.01
4.91
X (cm)
1.00
Y (cm)
0.60
(µsec)
0.73
(Hz)
7.91
(MPa)
4.48
pi
(cm)
pi
(cm)
4.00
(cm)
2.00
2
(W/cm
)
326.62
2.00
4.00
5
3
12
12
6.75
5.00
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TIS
TIB
Non-scan
Non-scan
A
>1
A
≤1
aprt
aprt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TIC
1.11
44.41
4.18
1.31
0.60
9.50
2.00
9.50
0.00
4
TIC
1.34
26.26
5.06
0.12
0.60
0.50
2.00
0.50
3
12
5.00
I n s t r u c t i o n s f o r U s e