Getting Started with the HP E1328A

Using This Chapter

D/A Converter Description

General Description

Chapter 1
This chapter describes the HP E1328A 4-Channel D/A Converter module,
and contains information on how to program it using SCPI (Standard
Commands for Programmable Instruments) commands. This chapter
contains the following sections:
D/A Converter Description . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11
Instrument Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 12
Programming the D/A Converter. . . . . . . . . . . . . . . . . . . . . . Page 13
The HP E1328A 4-Channel D/A Converter provides four independent,
16-bit isolated digital-to-analog channels configurable for either DC voltage
or DC current output. Figure 1-1 shows a block diagram for one of the four
HP E1328A channels. All four channels have the same block diagram.
Figure 1-1. D/A Converter Block Diagram
Each of the four channels can be programmed to output voltage or current in
one of the two operating modes.
Calibrated mode: output voltage range is ±10.922 Vdc and
output current range is ±21.84 mAdc.
Non-calibrated mode: output range is typically ±12 Vdc
and ±24 mAdc.