Smart Tweezers Iskra ST5L Manual

Testing leds

Advertisement

MODEL: Iskra ST5L

Testing LEDs

Press the control to turn on.
The device powers off automatically
if it is idle for about 60 seconds.
To reset test parameters to defaults press
the control for about 2 seconds and release.
To change the test current move the device
control UP or DOWN.
To switch through test pulse durations move
the control to the LEFT.
To switch through test modes move the
control to the RIGHT.
Connect the test leads to the LED contacts.
In the A mode diode polarity and forward
voltage drop value are displayed and the LED
lights up at the preset current.
In the M fixed modes the forward voltage drop
is displayed for forward connections.
In the M bidirectional mode a forward voltage
drop is displayed for each direction.
0.1, 1, 2, 5, 10, 20, 30 mA
UP
Defaults
10,
50,
100,
250,
RIGHT
LEFT
500 mS,
1 sec
DOWN
Testing modes:
A Automatic Polarity Detection
M Fixed Positive Signal
M Fixed Negative Signal
M Bidirectional LED Testing
A
M
M
M

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Iskra ST5L and is the answer not in the manual?

Questions and answers

Summary of Contents for Smart Tweezers Iskra ST5L

  • Page 1 MODEL: Iskra ST5L Testing LEDs  Press the control to turn on.  The device powers off automatically if it is idle for about 60 seconds.  To reset test parameters to defaults press the control for about 2 seconds and release.
  • Page 2 MODEL: Iskra ST5L Display Layout  Automatic A Mode  Diode polarity will be automatically detected  Fixed polarity M Positive mode  The sign indicates the preset test leads polarity  Fixed polarity M Negative mode  The sign indicates the preset test leads polarity ...

Table of Contents