Download Print this page
John Guest JGSTAT1 Instruction Manual

John Guest JGSTAT1 Instruction Manual

Aura 230v dial thermostat

Advertisement

Quick Links

230v Dial Thermostat
Instruction Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the JGSTAT1 and is the answer not in the manual?

Questions and answers

Summary of Contents for John Guest JGSTAT1

  • Page 1 230v Dial Thermostat Instruction Manual...
  • Page 2: Table Of Contents

    • Introduction • Product compliance Important info • Safety information • Mounting position and installation Your benefit • System grouping and communication • User interface • LED indication For latest PDF Instruction Manual please go to speedfitUFH.co.uk JGSTAT1 Instruction Manual...
  • Page 3: Introduction

    Safety Information. Thank you for purchasing the Use in Speedfit Aura Dial Thermostat JGSTAT1. This is accordance with the regulations. The a 230v Dial Thermostat which offers simple Aura JGSTAT1 is to be used for temperature control of your heating system.
  • Page 4 Instruction Manual only. Sources of danger. The thermostat Installer parameter settings. must be disconnected from mains The Aura JGSTAT1 is equipped with supply before removing the cover. Installer Parameters (see page 13). For the installer. Please enter any Emergency.
  • Page 5 Installation - Thermostat Mounting Mounting position and installation. To ensure trouble free operation and efficient control, the unit is best positioned in a draft free area and at 130cm from the floor. Do not position the thermostat near any heat source, behind curtains, direct sunlight or an area of high humidity.
  • Page 6: System Grouping And Communication

    The JGSTAT1 will follow instructions from the JGSTAT2 bringing central control of features such as Time Control, Holiday and Party functions as well as Frost Control. The JGSTAT1 can JGSTAT2 Group Control leave or re-enter group control at the slide of a switch.
  • Page 7 System Overview - Grouping and Communication The maximum number of groups per JGWC Wiring Centre is two. The group selection communication cable must correspond to the group terminals on the JGWC. Please refer to the JGWC Wiring Centre Instruction Manual. Group 1 –...
  • Page 8 Installation - Thermostat Mounting Carefully remove the front housing. Wall Mounting. For wall mounting, mark and mount the rear case to the wall. The JGSTAT1 is suitable for wall boxes with a centre hole distance of: 60mm JGSTAT1 Instruction Manual...
  • Page 9 Communication Terminals 12v DC. Two wire twisted Rear of unit pair can be used for grouping functions between JGSTAT2 and JGSTAT1. Also required for Heat/Cool changeover. Sensor Terminals. Can be used for external Air or Floor sensor. Power Terminals 230v...
  • Page 10 ONE 4 ONE 5 ONE 6 ONE 7 ONE 8 Optional communication connection 12v DC While the JGSTAT1 can function on its own, installing this optional, inexpensive communication cable allows JGSTAT1 to communicate with the Aura JGSTAT2 (sold separately). For more detail refer to the Wiring Centre Instruction Manual.
  • Page 11 Installation - Terminal Connections Check that the wiring is completed for: Power terminals. Sensor terminals (if applicable). Communication connections (optional but recommended). You are ready to secure the rear housing to the wall box. Please use the screws provided. Ensure the orientation arrow is pointing upwards.
  • Page 12 Installation - Thermostat Mounting If any parameter settings need Fit the front housing to the rear to be changed please refer to next page. housing as shown above. JGSTAT1 Instruction Manual...
  • Page 13 Installation - Parameter Setting External sensor (optional) If you are fitting an external sensor for air/floor sensing please select temp here. It can be set from 0ºC - 45ºC and is preset at 27ºC. Please note the dip switches need to be set for the correct external sensor type, see below.
  • Page 14: User Interface

    User Interface LED Indication Temperature Adjustment 5ºC - 30ºC The JGSTAT1 is no longer a member of the group and will ignore commands from the JGSTAT2 Group Control Thermostat. The JGSTAT1 is a group member and will follow Mode commands from the JGSTAT2 Group Control Thermostat.
  • Page 15 Group Control Thermostat will be in one of the following modes: For more details on JGSTAT2 please refer to JGSTAT2 Instruction Manual. If you do not want a JGSTAT1 to follow the Group Control Thermostat JGSTAT2. Please select . See previous page. speedfitUFH.co.uk...
  • Page 16 Group Control Thermostat will be in one of the following modes: For more details on JGSTAT2 please refer to JGSTAT2 Instruction Manual. If you do not want a JGSTAT1 to follow the Group Control Thermostat JGSTAT2. Please select . See page 14. JGSTAT1 Instruction Manual...
  • Page 17 Group Control Thermostat will be in one of the following modes: For more details on JGSTAT2 please refer to JGSTAT2 Instruction Manual. If you do not want a JGSTAT1 to follow the Group Control Thermostat JGSTAT2. Please select . See page 14. speedfitUFH.co.uk...
  • Page 18 To enter Manual Mode, slide the switch to the position. The thermostat will not follow the Group Control Thermostat JGSTAT2 and will no longer be part of the group. The JGSTAT1 will work as a stand alone thermostat. RED Led indicates that power is going to the unit in normal operation.
  • Page 19 LED Indication - Permanent Frost Mode To enter Manual Mode, slide the switch to the position. The thermostat will not follow the group control thermostat JGSTAT2 and will no longer be part of the group. The JGSTAT1 will be in permanent Frost Protection. Blue...
  • Page 20: Jgstat1

    Operating Temperature 0ºC to + 50ºC Storage Temperature -20ºC to + 60ºC Operating Humidity (non condensed) 5-95%RH POWER SOURCE 230v AC 50Hz CONTROL SWITCH AND RATING Loading Maximum 3A at SL terminal Input Comm Connection 12v DC JGSTAT1 Instruction Manual...
  • Page 21 Installer Notes speedfitUFH.co.uk...
  • Page 22 Installer Notes JGSTAT1 Instruction Manual...
  • Page 23 Installer Notes speedfitUFH.co.uk...
  • Page 24 Horton Road, West Drayton, Middlesex UB7 8JL, England. Tel: 01895 449233 Fax: 01895 420321 speedfitUFH.co.uk Technical Help Desk: 01895 425333 The above namestyles are all trademarks of John Guest International Limited. © John Guest International Limited 2017. All rights reserved. Z2105/423/0117...