Product compliance & safety information Introduction. Product Compliance. Thank This product is CE compliant and meets purchasing one of our Speedfit Aura the following European Directives: 230V Thermostat models. To use all of RoHS2 2011/65/EU, Electro- the Thermostat features, the optional Magnetic Compatibility directive communications cables are required.
Page 4
Product compliance & safety information These instructions are applicable to the Aura models stated on the front cover of this Quick Set-up Guide only. Warning. This product must be 230 AC fitted by a competent person. Installation must comply with the guidance, standards regulations applicable to the...
Terminal connections Understanding the terminal connections on your thermostat. Rear of thermostat unit Live, Neutral and Switch Live Group communications cable Sensor / Probe terminals JGSTAT2 Quick Set-up Guide...
Model pre-sets The enclosed unit has been pre-set to function as a standalone Programmable Room Thermostat (PRT). On connection to mains power, the unit will display the following start-up sequence: The unit can also function as a Group Control Thermostat, a Group Thermostat or a Hot Water Timer.
Configuration options A Group set up will consist of 1 Master and up to 7 digital thermostats. Each thermostat will have its own temperature control of a room but share a common time programme that will be dictated by the Group Master thermostat. Each digital thermostat will join the group when put into (Automatic) or will leave the group and become a stand alone manual (temperature only) digital thermostat when moved out of (Automatic).
Customising from default configurations If any other configuration is needed then the thermostat must first be put into set up mode. In order to do this follow the instructions below. Press and hold bottom 3 buttons until the Using scroll through the numbers to above screen is shown.
Setting device configuration SO 1 (Set-up Menu 1) to select the type of thermostat you want. 0: Is to select a Programmable Room Thermostat or Group Master (time and temperature). 1: Is to select a Digital (temperature only) Thermostat 2: Is to select a Hot Water Timer (time control only) Once you have made your selection press CONFIRM The screen will now scroll to...
Setting device communication SO 3 (Set-up Menu 3) S 03 (Set-up menu 3) is where you will confirm if the optional Command / Communication cable has been used. Use to select the option you want. 0: Not for the UK. This option is for Heat / Cool with the optional Command Cable fitted.