Turnigy Quad 4x6S Operating Manual

Turnigy Quad 4x6S Operating Manual

Lithium polymer charger 400w dc only. balance charger/discharger for nicd/nimh/lithium/pb batteries

Advertisement

BALANCE CHARGER/DISCHARGER
FOR NICD/NIMH/LITHIUM/PB BATTERIES
Thank you for purchasing the balance charger. This is a rapid charge/
discharger with built in balancer, computerised with microprocessor and
specialised operating software. Please read this entire operating manual
completely and attentively before using.
Operating Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Quad 4x6S and is the answer not in the manual?

Questions and answers

Summary of Contents for Turnigy Quad 4x6S

  • Page 1 BALANCE CHARGER/DISCHARGER FOR NICD/NIMH/LITHIUM/PB BATTERIES Operating Manual Thank you for purchasing the balance charger. This is a rapid charge/ discharger with built in balancer, computerised with microprocessor and specialised operating software. Please read this entire operating manual completely and attentively before using.
  • Page 2: Table Of Contents

    Contents Features Exterior of the unit Warnings and safety notes Program flow chart Initial Parameter set up (Users' set up) Lithium battery(Lilo/LiPo/LiFe)program Charging Lithium Battery Charging Lithium battery at balance mode 'FAST' charging Lithium battery 'STORAGE' control Lithium battery Discharging Lithium battery Voltage balancing and monitoring during the discharge NiMH/NiCd battery program Charging NiCd/NiMH battery...
  • Page 3: Features

    1. Features Optimised operating software When charging or discharging, It has an 'AUTO' function that sets the feeding current automatically. Especially for Lithium batteries, it can prevent the over-charging can lead to an explosion by users fault. Every program in the unit is controlled with mutual links and communication for every possible error so it introduces a maximum safety.
  • Page 4 Auto-charge current limit: When charging NiCd or NiMH at 'AUTO' current mode, you can set the upper limit of change current to avoid from high current charging. This is very useful when charging the low impedance and small capacity NiMH battery in 'AUTO' mode. Capacity limit: The changing capacity always calculated by multiple of the charging current and time.
  • Page 5: Exterior Of The Unit

    2. Exterior of the unit LCD Screen Menu Control Buttons INPUT DC 11~18V Ventilation Fan Ventilation Fan...
  • Page 6: Warnings And Safety Notes

    3. Warnings and safety notes Never leave the charge unsupervised when it is connected to its power supply. If any malfunction is observed immediately terminate the process and refer to the operation manual. Keep away the unit from dust, damp, rain, heat, direct, sunshine and vibration. Do not dorp it.
  • Page 7 Do not connect more than one battery pack to the charge lead at any one time. Do not attempt to charge or discharge the following types of battery. - Battery pack, which consists of different types of cell (including different manufacturers). - Battery, which is already fully charged or just slightly discharged.
  • Page 8 Discharge The typical purpose of discharge is to determine the residual capacity of the battery, or to lower the voltage of battery to a defined level. When you discharge the battery you also have to pay attention on the process same as charging. To avoid the battery becoming deep- discharged, set the final discharge voltage correctly.
  • Page 9: Program Flow Chart

    4. Program flow chart Start Enter USER PROGAM LiPo/LiIo/LiFe Product Version Load Factory Set Input Power Low SETUP CHK Timer 10min V1.0.0 Enter Cut-off 10.0V Batt type stop Start Key Beep Enter LiPo[0] CHARGE LiPo[0] DISCHG Buzzer PROGRAM MEMORY 10.0A 22.2 (6S) 2.0A 22.2 (6S)
  • Page 10: Initial Parameter Set Up (Users' Set Up)

    5. Initial Parameter set up (Users' set up) It will be operated with the default value of the essential user settings when it is connected to a DC 10~18V batttery for the first time.The screen displays the following information in sequence and the user can change the value of parameter on each screen.
  • Page 11 The battery is on the cyclic process of charge and discharge can often become warm after charge or discharge period. The program can insert a time delay to occur after each charge and discharge process to allow the battery adequate time to cool down before being subjected to the next process.
  • Page 12: Lithium Battery(Lilo/Lipo/Life)Program

    6. Lithium battery(Lilo/LiPo/LiFe/LiHV)program These programs are only suitable for charging and discharging Lithium batteries with a nominal voltage of 3.3V,3.6V,3.7V and 3.8V per cell. These batteries need to adopt different charge technique is termed a constant voltage(CV) and constant current(CC) method. The charge current varies according to the battery capacity and performance.
  • Page 13: Charging Lithium Battery At Balance Mode

    6.2 Charging Lithium battery at balance mode This function is for balancing the voltage of Lithium-polymer battery cells while charging. In the balance mode, the battery needs to have a balance lead to connect to the battery's power lead to the output of chaeger. In this mode, the charging process will be different from ordinary charging mode.
  • Page 14: Storage' Control Lithium Battery

    The shows the present state of 'FAST' charging. To stop charging arbitrary, press Batt type/Stop key once . 6.4 'STORAGE' control of lithium battery This is for charging or discharging Lithium battery not to be used for the time being. The program will determine to charge or discharge the battery to the certain voltage depending on the voltage of the battery at its initial stage.
  • Page 15: Voltage Balancing And Monitoring During The Discharge

    6.6 Voltage balancing and monitoring during the discharge The processor monitors the voltage of individual cells during 'storage-mode' and 'discharge' of Lithium battery pack. It tries to normalise the voltages to be equal. For this feature, the individual plug of the battry pack should be connected to the individual port of the charger.
  • Page 16: Discharging Nicd/Nimh Battery

    7.2 Discharging of NiCd/NiMH battery Set discharge current on the left and final voltage on the right. The discharge current ranges from 0.1 to 1.0A and the final voltage ranges from 0.1 to 25.0V). To start the process, press Start /Enter key more than 3 seconds. The screen displays the current state of discharge.
  • Page 17: Pb( Lead-Sulphuric Acid) Battery Program

    8. Pb( lead-sulphuric acid) battery program This is programmed for charging Pb( lead-sulphuric acid) battery with nominal voltage from 2 to 36V. Pb batteries are totally different from NiCd or NiMH batteries. They can only deliver relatievely lower current compare to their capacity, and similar restrictions definitely apply to charge.
  • Page 18: Cell Meter Test Program

    9. Cell Meter test program 10. IR test program...
  • Page 19: Memory Mode

    11. Memory Mode 12. Various information during the process You can inquire various information on LCD screen during charging or discharging process. When you press DEC button the charger shows the establishment of user settings. And also you can monitor the voltage of individual cell by pressing INC button when the individual connection cable is linked to the Lithium battery being processed.
  • Page 20: Warning And Error Messages

    Displayed capacity cut-off function is turn on and the setting value of capacity. Displayed safety timer is turn on and duration of time in minutes. Displayde temperature cut-off function is turn on. The external temperature is displayed when the temperature probe is used. Present input voltage.
  • Page 21 Input voltage wrong. The voltage of the battery pack has been selected incorrectly! The charger has malfunctioned for some reason. Seek professional advice. The voltage is lower than which is set. Please check the number of cells in the battery pack. The voltage is higher than which is set.
  • Page 22: Specifications

    14. Specifications Stated values refer to one charger except dimension & weight DC 10.0 ~ 18.0 Volt DC 10.0 ~ 18.0 Volt Operating Voltage Range: Max.100 Watts for each pc. Max.50 Watts for each pc. Charge Power: Max.5 Watts for each pc. Max.5 Watts for each pc.
  • Page 23: Warranty And Service

    15. Warranty and service We warrant this product for a period of one year(12 months) from the date of purchase. The guarantee applies only to such material or operational defects, which are present at the time of purchasing the product. During that period, we will replace without service charge any product deemed defective due to those causes.