Hanging The Fan - GE 20338 User Manual

Phantom led ceiling fan 54in (1.37m)
Table of Contents

Advertisement

Available languages

Available languages

HANGING THE FAN

1.
V
CC
Remove the clevis pin (CC),
cotter pin (DD) and loosen 2 collar
set screws (BB) from the top of the
fan motor assembly (V).
Take out the setscrew located in
the hanger ball, lower the hanger
ball and remove the cross pin.
Remove the hanger ball from the
hanger ball/downrod assembly (T).
4.
CC
Insert the cotter pin (DD)
through the hole near the end of
the clevis pin (CC) until it snaps
into its locked position.
Fan Installation
2.
T
DD
BB
Carefully feed the motor wires
up through the downrod (T).
Thread the downrod (T) into
the collar.
Slip the coupling cover (U),
canopy cover (S) and canopy (R)
onto the downrod (T).
Carefully reinstall the hanger
ball onto the downrod (T), being
sure that the cross pin is in the
correct position, the setscrew
is tightened and wires are not
twisted.
5.
DD
Tighten two set screws (BB)
at top of the fan motor collar
firmly and evenly until fully
engaged. Once set screws have
been installed, tighten each
nut (located on set screws)
completely against motor collar.
BB
3.
T
T
R
CC
S
U
Align the holes at the bottom
of the downrod (T) with the holes
in the collar on top of the fan
motor assembly (V). Carefully
insert the clevis pin (CC) through
the holes in the collar and
downrod (T). Be careful not to
jam the clevis pin (CC) against
the wiring inside the downrod (T).
WARNING: Failure to properly
install cotter pin as noted in step
4 could result in fan loosening
and possibly falling.
DD
BB
V
9