Page 1
Operating Manual English CX22B-R catman Data Recorder...
Page 2
Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com Mat.: 7-2002.4722 DVS: A4722-1.0 HBM: public 12.2017 E Hottinger Baldwin Messtechnik GmbH. Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or...
The same applies to the use of accessories. Notice If the measurement module is not used as intended or is used outside the ratings, the protection provided by the module may be impaired. CX22B-R A4722-1.0 HBM: public...
Page 6
10 V … 30 V CX23‐R 10 V … 30 V EX23‐R 10 V … 36 V MX modules 10 V … 30 V Notice The module must not be connected directly to the power supply system. CX22B-R A4722-1.0 HBM: public...
Page 7
The modules are maintenance-free. Only trained and qualified personnel who are authorized to do so by HBM are allowed to open the module. Before opening the module, disconnect all connections. Opera tion when open is not allowed. Once the device has been opened, it must be professionally inspected in accor...
Page 8
Safety instructions Only trained and qualified personnel who are authorized to do so by HBM are allowed to change these batteries. Notice If the module is opened, modified, or inexpertly repaired, the protection provided by the module may be impaired.
Page 9
61326-1 / EN 61326-2-x. These standards define emis sion limits and immunity requirements for multiple envi ronments. With respect to emissions, the standards contain limits for industrial (class A) and residential / commercial (class B) environments. The standard herein references CISPR 11:2009+A1:2010. CX22B-R A4722-1.0 HBM: public...
Page 10
The supply connection, as well as the signal and sense leads, must be installed in such a way that electromag netic interference does not adversely affect device func tionality. (HBM recommendation: "Greenline shielding design," downloadable from the Internet at http://www.hbm.com/greenline.) The measurement module and devices used in automa...
Page 11
S As system startup engineers or service engineers, they have successfully completed the training to qual ify them to repair the automation systems. They are also authorized to activate, ground and label CX22B-R A4722-1.0 HBM: public...
Page 12
The same also applies to the use of accessories. Maintenance and repair work on an open device with the power on may only be carried out by trained personnel who are aware of the dangers involved. CX22B-R A4722-1.0 HBM: public...
Arrows between menu items indicate the sequence in which the menus and sub-menus are called up Data rate Bold text in italics indicates inputs and input fields in the user interfaces. ► Instructions are marked by a small, right-pointing triangle. CX22B-R A4722-1.0 HBM: public...
The CE mark enables the manufacturer to guarantee that the product complies with the requirements of the rele vant EC directives (the Declaration of Conformity can be found on the HBM support website www.hbm.com. Statutory waste disposal mark see Chapter, Chapter 14.
Messtechnik GmbH. All trademarks and brands used in this document are belonging to the respective product or the manufacturer/ owner. Hottinger Baldwin Messtechnik GmbH does not lay claim to any other than their own trade names/trade marks. CX22B-R A4722-1.0 HBM: public...
The device is a SomatXR module with the "Windows Embedded‐8 Standard " operating system and pre-installed catman Easy software from HBM. Most of the software functionality is described in the data sheet. Interfaces on the back of the Data Recorder: CX22B-R A4722-1.0 HBM: public...
Page 17
S WLAN for a sma antenna The following interfaces and options can be found on the front: S 2 x Gigabit Ethernet 2 x USB 2.0, 1 x DVI‐D S 3 x digital inputs and 3 x digital outputs CX22B-R A4722-1.0 HBM: public...
Status LEDs (1+2) 2x USB 2.0 Protection caps Monitor (DVI-D) Fig. 4.1 CX22B‒R connections on the front Supply voltage DC 10 V … 30 V WLAN antenna Grounding 2x Fire Wire Fig. 4.2 CX22B-R connections on the back CX22B-R A4722-1.0 HBM: public...
MX modules need a separate UPS for buffering. Details about the UPS and its settings can be found in chapter 6.6. HBM offers the NTX002 power supply for laboratory or general steady-state operation. On the primary side, this provides a selection of international connector types and 24 V and 30 watts on the secondary side.
Important The data recorder hosts a small buffer battery. This battery keeps date and time during power interruptions. The battery shall only be replaced by HBM service. Ground connection and grounding Lay the signal and data leads separately from current- carrying power lines.
(standard in Windows) - Direct connection via an Ethernet patch cable - Wireless connection (WLAN) - In a network (LAN) - Remote access via an Internet connection and a mobile services provider using a mobile services gateway CX22B-R A4722-1.0 HBM: public...
The level for the outputs is 5 volts (HIGH), when the cor responding output is set, otherwise 0 volts (LOW). The line lengths at the outputs must not exceed 3 m. Maxi mum output current is 1 mA. CX22B-R A4722-1.0 HBM: public...
Reset all CX22B‒R digital outputs at the start of a DAQ job. LED displays Fig. 4.3 Position of the LEDs Function Operating condition status POWER = Module LED ERROR LED RUN = RECORDING LED CX22B-R A4722-1.0 HBM: public...
Page 24
Connections and displays Fig. 4.4 Pin assignment digital In ‐ and Output CX22B-R A4722-1.0 HBM: public...
Page 25
All Status LEDs can also be triggered via Limit values and events in catman EASY. To do this select Set dig ital output: CX22B-R digital output in the Configure limit value and event monitoring dialog and enter the required LED in Bit/Condition . CX22B-R A4722-1.0 HBM: public...
MX modules via a separate battery or a UPS (e.g. UPX002). The integrated UPS of the CX22B-R will not power the connected modules. In case of voltage drops the measurement will stop if the MX modules are not buffered. CX22B-R A4722-1.0 HBM: public...
Page 27
Data Recorder and is located in the sub-directory C:\Program Files (x86)\HBM\catmanEasy_EN\Firmware\QuantumX-B\ DC 10 V ... 30 V X102 X101 FireWire connection 1-Kab272-x: connection cables of various lengths (x m) Fig. 5.1 Connecting MX modules to the CX22B-R via FireWire CX22B-R A4722-1.0 HBM: public...
Page 28
PTPv2 capable Ethernet switch (e.g. EX23-R) is required. DC 10 V ... 30 V X102 X101 Ethernet WLAN DC 10 V ... 30 V Fig. 5.2 Connecting MX modules to the CX22B-R via Ethernet CX22B-R A4722-1.0 HBM: public...
If necessary, use the Windows control panel ("Regional and Language Options") to set the Location) to your country. The setting influences the digit settings and the time, for example. CX22B-R A4722-1.0 HBM: public...
Page 30
Easy software can be updated free of charge for 12 months from the date of delivery. To run an update, you must first register with HBM, in order to benefit from software maintenance. To do this, simply send us the registration file created during initial start-up.
To make it easier to set up a connection when the CX22B‒R settings are unknown, use the HBM program HBM Device Manager, which is part of the system soft ware and included in the package as a DVD. It is also available to download from www.hbm.com.
CAT5e or higher. ► Install the HBM Device Manager program, which can be found on the HBM support sites or in the software package QuantumX / SomatXR system software. ► Launch the HBM Device Manager program on the PC: ►...
Page 33
► Select the CX22B‒R from the list. ► In the TCP/IP settings for CX22B‒R, click on LAN and enter the required IP address and subnet mask. An address and subnet mask that are within the ad CX22B-R A4722-1.0 HBM: public...
Page 34
Remote connect. ► If Windows asks whether the connection should be set up to this remote computer, set up the connection (Fig. 6.2). We recommend activating the option Don't ask me again for connections to this computer. CX22B-R A4722-1.0 HBM: public...
Page 35
► Depending on the configuration of your Windows operating system, another query whether the connec tion should be set up may be displayed (identity of the remote computer, Fig. 6.3). If necessary, activate the option to prevent the query. CX22B-R A4722-1.0 HBM: public...
Page 36
Operating the Data Recorder Fig. 6.3 Identity of the remote computer display The connection to the CX22B‒R Data Recorder will now be implemented and you must register with the device (Windows login dialog). CX22B-R A4722-1.0 HBM: public...
Page 37
Commit changes and reboot or Save and restart, if you have yet to change the language in the settings. This will permanently save the new settings. The recorder will then restart. You will have to set up the connection again after the restart. CX22B-R A4722-1.0 HBM: public...
The settings for the CX22B‒R Data Recorder again de pend on your network configuration. Please contact your network administrator to obtain the correct settings. ► Install the "HBM Device Manager" program from the system CD. ► Launch the program on your desktop or via the Win...
The WLAN connection that was previously set-up is lost). ► You can then remove the network cable and use your PC to find the CX22B‒R wireless network and con nect to it. CX22B-R A4722-1.0 HBM: public...
Page 40
Operating the Data Recorder ► Now use the HBM Device Manager tool to set up an Adhoc connection to the CX22B‒R. Configuring the CX22B‒R for an Access Point ► To set up the wireless connection, you must first cre ate access to the CX22B‒R. This is done convention...
Microsoft website). For other operating systems, there are numerous pro grams for setting up a remote desktop connection to a Windows PC, such as the Remote Desktop for Mobiles RDM+ program for BlackBerry, Android or iPad. CX22B-R A4722-1.0 HBM: public...
Operating the Data Recorder Connection via remote desktop If you do not want to use the HBM Device Manager pro gram or you are working with a permanent IP address at the recorder end, you can also set up the connection di...
Page 43
Enter the IP address of the CX22B‒R and click on Options. S Change the definition used by the HBM Device Man ager program. To do this, open the CX22B.rdp file in the installation directory of the HBM Device Manager software.
Page 44
Activate data exchange via the clipboard Fig. 6.6 Remote desktop connection local resources tab ► Click on Next in the Local resources tab. ► Enable the required drives of your PC for use in the CX22B‒R (Fig. 6.7). CX22B-R A4722-1.0 HBM: public...
Page 45
Dialog for enabling additional resources ► Close the dialog. ► Save the configuration via the General tab either under a new name (Save as) or as a default setting for the connection via HBM Device Manager (Save), see Fig. 6.8. CX22B-R A4722-1.0 HBM: public...
Page 46
If you double-click this configuration file (or a link to it), a connection to the CX22B‒R is immediately set up, and you only have to enter the password. If you authorize Save credentials (see Fig. 6.8), this is done automati cally. CX22B-R A4722-1.0 HBM: public...
Operating the Data Recorder Detecting and resolving connection problems If the CX22B‒R does not appear in the HBM Device Manager list, or the setup of the remote desktop connec tion is canceled, there are several possible causes. Check the following points and then repeat the search: S Has the CX22B‒R been switched on for at least 1...
S If your PC has several Ethernet interfaces, try deactivating all the other Ethernet interfaces. S If the HBM Device Manager cannot find the CX22B‒R, try setting up a "standard" remote desktop connection.
90 seconds) if the used MX modules are also buffered. After that time, all standard catman actions can take place. In addition it is also possible to store the data, shut-down catman and to restart catman after the power is back. CX22B-R A4722-1.0 HBM: public...
Page 50
Operating the Data Recorder Notice To shut-down CX22B-R please unplug the power con nection. Otherwise the data recorder will reboot after a few seconds automatically. CX22B-R A4722-1.0 HBM: public...
as the language of catman EASY. The Info tab con tains information about the CX22B‒R hardware (ID), the device serial number and the firmware version. Also see Section12.2. CX22B-R A4722-1.0 HBM: public...
Page 52
General tab. Recalling the start screen If you have used Exit to Windows to exit the start screen, you can recall it via CX22Shell (on the Windows desktop). The link brings the start screen to the top. CX22B-R A4722-1.0 HBM: public...
In catman EASY, each channel is identified by its name, so you must use meaningful names where possible. ► Mark the channels to be set to zero and run a zero balance (zero balance, group zero balance). CX22B-R A4722-1.0 HBM: public...
Page 54
Otherwise a monitor must be connected during measurement in order to save the data. ► Generate visualization − if a monitor is connected. ► Save your DAQ project: File menu −> Save −> Project. CX22B-R A4722-1.0 HBM: public...
Page 55
EASY can be found in EASY online Help. the catman General default settings, data storage and directories You should also consider whether additional directories should be specified as default settings, and how to pro ceed with the sensor database. CX22B-R A4722-1.0 HBM: public...
Page 56
English sensor database is used once catman launched. But you can switch this to a German or French language database. To do this, you first have to change the language in the settings and then launch catman CX22B-R A4722-1.0 HBM: public...
Page 57
► In catman EASY, use the Sensor database context tab and the File menu to load the relevant sensor database from the installation directory "C:\Program Files (x86)\HBM\catmanEasy_DE\" or "C:\Program Files (x86)\HBM\catmanEasy_FR\". ► Save this sensor database under a different name to ...
PC's drives are integrated as ad ditional CX22B‒RW drives, see Section 6.3. 4. Via Windows Explorer: Enter the IP address of the CX22B‒R in Windows Explorer (Fig. 8.2, enter \\ in front of the address). CX22B-R A4722-1.0 HBM: public...
Page 59
In the logon dialog, enter the name of the CX22B‒R, the user name and the password. In the factory set tings, the device name is "CX serial number" and the user name is HBMCX22. In this case, enter HBMCX22 and the password hbm (Fig. 8.3). CX22B-R A4722-1.0 HBM: public...
To do this, start an evaluation project in catman EASY or switch from measurement mode to evaluation mode. S On your PC: To do this, you can use catman EASY/AP, catman Post Process or GlyphWorks from HBM, for example. CX22B-R A4722-1.0 HBM: public...
It has its own set of chan nels to be recorded and individual sample rates including downsampling. Recordings can be repeated, i.e. after CX22B-R A4722-1.0 HBM: public...
Page 62
HBM in the Internet) to any mobile smart device (e.g. iPhone, Android based devices) worldwide. On the mobile device you only need to install the HBM Push App ("HBM Push") which you can download from the App Store (e.g. Google Play Store for android based devices or Apple App Store for iPhone or iPad).
Configuring the CX22B‒R for self-contained measurements Configuring the CX22B‒R for self-contained measurements Catman can be launched via the start screen (Settings button): Fig. 9.1 CX22 catman start‐up settings CX22B-R A4722-1.0 HBM: public...
Page 64
► Go to DAQ channels in the Channels and sensors group. ► Activate the option Automatically deactivate faulty channels and continue measurement (behavior if channel initialization fails). ► Exit the dialog by clicking on OK. CX22B-R A4722-1.0 HBM: public...
Page 65
Important The data are lost during an interruption to the power sup ply if the temporary measurement data memory is set to dynamic in the catman settings ("Use fixed memory size" is not set). CX22B-R A4722-1.0 HBM: public...
Page 66
Configuring the CX22B‒R for self-contained measurements CX22B-R A4722-1.0 HBM: public...
Section 10.3). In the start screen, click on Commit changes and reboot, to permanently save the new set tings or the newly installed software. The CX22B‒R is then rebooted, so you must set up the connection again after the restart. CX22B-R A4722-1.0 HBM: public...
This could happen, for example, if the voltage supply fails and Windows is not properly shut down. In this situation, the program always restores the "previous" state when the CX22B‒R is next switched CX22B-R A4722-1.0 HBM: public...
Page 69
If you want to permanently save settings or programs on C:, you must use Commit changes and reboot in the start screen ("CX22Shell"). Changes will then be perma nently applied and will also be available the next time you restart the CX22B‒R. CX22B-R A4722-1.0 HBM: public...
11.2 Activate/deactivate gateway mode To activate/deactivate the gateway mode, go in the Shell settings of the CX22B-R into the "General" tab. Check the option "Activate gateway functionality" to activate the option and uncheck it to deactivate it. CX22B-R A4722-1.0 HBM: public...
CX22B-R, look for this module in the cat man's device manager module list. The modules routed by the CX22B-R are displayed as child elements of the CX22B-R. Unlike the CX27, you can select QuantumX/ SomatXR modules individually. CX22B-R A4722-1.0 HBM: public...
Page 72
Operating the CX22B-R as gateway Important note: You can connect only time simultane ously to a QuantumX/SomatXR module being routed by the CX22B-R. Successvie connections will fail. CX22B-R A4722-1.0 HBM: public...
CX22B‒R Data Recorder. If addi tional software is installed, the functionality of the CX22B‒R Data Recorder can no longer be guaranteed and HBM can no longer provide support for any faults arising in this connection. In practice, drivers have already been successfully in...
Commit changes and reboot in the start screen af ter making any changes. In the start screen, click on Settings and go to the appropriate tab to change the settings. CX22B-R A4722-1.0 HBM: public...
Page 76
Adhoc profile, so that a direct WiFi connection can be set up to the CX22B-R. Important Store the password safely after changing it. If you lose it you will need to restore the system to obtain access to the CX22B‒R again. CX22B-R A4722-1.0 HBM: public...
USB flash drive, a keyboard and, where possible, a (digital) monitor that you can connect directly to the CX22B‒R (DVI out put). Please contact our support site (http://www.hbm. com/support) CX22B-R A4722-1.0 HBM: public...
Module decoupled A module or an entire module string may become detached, particularly in the distributed module group, e.g. in trains. You have the option to configure catman so that measurement continues or is canceled. CX22B-R A4722-1.0 HBM: public...
15, §103 of the FCC rules and ICES-003, chapter 4. Connection of equip ment, changes or modifications not expressly aut horized by HBM (e.g. by this product manual) may cause additional interference and could void the users authority to operate the CX22B-R.
Page 80
HBM webpage: www.hbm.com Every connection of equipment, changes or modifi cations not expressly authorized by HBM may cause additional interference and could void the user’s authority to operate the CX22B-R. This is particularly applicable when replacing the antenna.
Packaging The original packaging of HBM devices is made from re cyclable material and can be sent for recycling. For ecological reasons, empty packaging should not be re...
Page 82
20 years, and will be ecological lly safe to use during this period, as well as recyclable. This is documented by the alongside symbol. Statutory mark of compliance with emission limits in the electronic equipment supplied to China. CX22B-R A4722-1.0 HBM: public...
Need help?
Do you have a question about the SomatXR CX22B-R and is the answer not in the manual?
Questions and answers