January 23, 2025
Location of thermostat
Robert Mackay
February 10, 2025
One of my RCTT heaters has suddenly stopped heating. It is still connected to the WiFi an communicating ok but the heater does not turn on either on the heater control or remotely. I have turned the heater off and on and reconfigured from the start a second time with no success. Can you offer any further advice. Thanks
1 comments:
Mr. Anderson
February 11, 2025
The Haverland Designer RCTT heater may have stopped heating despite being connected to WiFi due to a power cut or disconnection from the mains. If the power cut lasted more than 24 hours, you need to reset the day and time following the instructions in the manual. If the power cut was shorter, all settings should be retained. Additionally, check if the heater is in "frost protection mode" and switch it back to heating mode if necessary. Ensure the heater is clean and functioning properly.
Page 5
Instructions for installation Place radiator over lower tang of the 4 screws bracket Screw both brackets firmly into position The two 6 x 50mm screws Place over top supplied should be fully tang and lower screwed down to lock the gently into radiator onto the brackets.
Page 12
Note: if you wish to reset the counter, repeat steps 1-4 and Press ,. for 3 seconds. The counter will automatically reboot every 30 days. HAVERLAND ® lnnovators, designers and manufacturers of New Generation Electric Heating Haverland UK Limited Challenge House, Sherwood Drive, Bletchley MK3 6DP Customer Service Telephone: 0330 3651940 Fax:01672811944 email: haverland@haverland.co.uk...
Page 13
RCTT WARRANTY Date of purchase [I] [I] [I] Month Year Name of your supplier Town / City Your name Address Post code Telephone email Product code Customer service telephone: 0330 3651940...
Page 14
3. lf you have to evoke the guarantee, take the 2.2. The guarantee only applies to the cases radiator to the distributor / installer where you relative to material, design or acquired it. In the case of problems, Haverland manufacturing faults; under no places the Technical Assistance Telephone...
Need help?
Do you have a question about the Designer RCTT and is the answer not in the manual?
Questions and answers
Location of thermostat
One of my RCTT heaters has suddenly stopped heating. It is still connected to the WiFi an communicating ok but the heater does not turn on either on the heater control or remotely. I have turned the heater off and on and reconfigured from the start a second time with no success. Can you offer any further advice. Thanks
The Haverland Designer RCTT heater may have stopped heating despite being connected to WiFi due to a power cut or disconnection from the mains. If the power cut lasted more than 24 hours, you need to reset the day and time following the instructions in the manual. If the power cut was shorter, all settings should be retained. Additionally, check if the heater is in "frost protection mode" and switch it back to heating mode if necessary. Ensure the heater is clean and functioning properly.
This answer is automatically generated