Thermo GSM Digital thermostat • Comfort and control of consumptions are ensured both in winter and in summer (heating/air conditioning) • Integrated GSM module for the remote control of the thermostat by mobile phone • Power supply: 230 V AC (with rechargeable backup battery NiMh type AA) •...
ASSEMBLY • It is recommended to place the thermostat in an area that has, as much as possible, the conditions of average temperature of the entire environment. Avoid installing too close to doors, windows, heat sources, direct sunlight radiation, and positions with excess or total lack of aeration.
■ Thermo GSM is a wall-mounting electronic thermostat with a built-in GSM interface, available with weekly programming. The instrument performes 1B type actions and it is suitable for installations in ambient with a pollution degree of 2 and overvoltage category III (EN 60730-1). The GSM interface permits the total control of the thermostat, also remotely, by sending text message commands.
TECHNICAL FEATURES • Power supply: 230 V AC (-15% ÷ +10%) 50/60Hz • Charge reserve: about 1 hour thanks to the backup battery • Backup battery:NiMH rechargeable type AA, capacity 2000 mAh or higher Use only rechargeable battery • Auxiliary input configurable to connect alternately: –...
CONTROL ELEMENTS / DISPLAY INDICATIONS Control elements ■ 1) “ ” Key: to confirm the set value / to enter the advanced programming 2) “ ” Key: to increase the setpoint, to increase the selected field 3) “ ” Key: to decrease the setpoint, to decrease the selected field.
Page 10
Display indications ■ 6) “Stored numbers in bookphone” Field 7) “External temperature” Field 8) “Ambient temperature” Field 9) “Air conditioning activation” Field 10) “Heating activation” Field 11) “Clock” Field 12) “Receiving remote command (via GSM)” Field 13) “GSM connection” Field 14) “Unit of measurement”...
INITIAL START-UP / RESET • Mount the thermostat to the wall, connect the power supply, the output relay and the external probe (if present) or external contact to the rear terminals. Then fix the thermostat to its base. • Insert a SIM card enabled for telephone traffic into specific slot.
Note: if the automatic update of Daylight Saving Time (DST) is activated (Change = ON): - winter time -> summer time: last Sunday in March at 2:00 AM - summer time -> winter time: last Sunday in October at 3:00 AM Note: if the automatic update of Daylight Saving Time (DST) is not desired, it is necessary to deactivate it manually.
SWITCHING ON/OFF • To switch the thermostat off, press the key “ ” for 3 seconds until the symbol “ ” appears on the display. When the thermostat is OFF (in winter- heating operating mode), it activates the antifreeze function to prevent the temperature decrease under a specific threshold.
ADVANCED PROGRAMMING • In advanced programming it is possible to enter the following operating parameters: - language selection - regulation type - parameters for the selected regulation type - Antifreeze temperature - temperature correction page - setting the external auxiliary input - regulation probe selection - GSM function page - minimum settable value as setpoint (LO)
Page 15
Regulation type (only for winter operating mode) • Field (11) displays the writing “ rEG= ” and on field (8) letter “ O ” (ON-OFF programming) or “ P ” (proportional programming) starts flashing. • Using the keys “ ” and “ ”...
Page 16
Once the band value is confirmed, field (11) displays the writing “ PEr= ” and on field (8) the value currently set starts flashing. Press the keys “ ” and “ ” to increase or decrease the value. It is possible to choose between 10, 20 or 30 minutes.
Page 17
The set value is added or subtracted to the measured temperature. Values range from -5.0°C to +5.0°C Setting the external auxiliary input The thermostat allows to connect a remote external temperature probe for the displaying (and in case also regulation) of the measured temperature where the probe is placed, or a non-voltage contact if an auxiliary device is connected (for example, a gas detector, an anti-theft system, block detection boiler system, ...).
Page 18
Regulation probe selection In case an external probe is present, it is possibile to choose when using the internal or external probe as a regulation sensor. Field (11) dispalys the writing “ SnS= ” and on field (8) the value currently set starts flashing.
Page 19
On field (11) the symbol “HI=” appears and on field (8) the maximum value of the setpoint starts flashing. Press the keys “ ” and “ ” to increase or decrease the value and the key “ ” to confirm. Settable values: LO ÷...
Page 20
Ending time setting of night operating mode (End) • The thermostat Thermo GSM permits to specify a night time slot where it is possible to adjust the temperature with a setpoint lower than the daily time slot. This menu permits to specify the ending time of the night time slot. •...
System operating hours It is possible to display the operating hours of the system (relay in ON status). Field (7) displays the writing “ tot= ” while fields (11) and (8) dispaly the timing value (this value consists of 5 digits, 3 on field (11) and 2 on field (8) and the reading direction is from left to right.
REGULATION TYPE The default set regulation is ON/OFF with deactivation just at the setpoint and with differential set at 0.3°C. In ON/OFF operating mode, the output relay follows the logic below: heating mode cooling mode relay ON relay ON relay OFF relay OFF SET-DIFF SET+DIFF...
GSM INTERFACE ■ The Thermo GSM has an interface module with built-in GSM that can manage the thermostat remotely, just using a mobile phone. The functions associated with the GSM mode are: • via a telephone ring – ON/OFF of the thermostat •...
Page 24
Notes: – it is necessary to separate the words by one or more blanks – the password field may be omitted if the message sender is a number in the phonebook (see the procedure for phonebook management below) – several commands may be included in a single message for maximum of 160 characters (standard text message).
Page 25
Recording phone numbers in the phonebook The Thermo GSM permits storing within 5 phone numbers in the phonebook, identified with a progressive number from 1 to 5, which can activate/deactivate the instrument with a ring or send text message commands or receive alarms. Storing the first phone numbers in the phonebook To store the first phone number, from the normal operating status: –...
Page 26
Note: remember that if the command sender is not in the telephone book, it is necessary to enter the password before writing the command. For example: PHONEBOOK 2 3921234567 The device replies with a text message confirmation containing the complete phonebook (if a number is not defined, it is indicated with the writing “EMPTY”).
to Thermo GSM with the selected phone number to check it: if the phone number is in the phonebook, the index of the corresponding memory starts flashing (in the example, the phone number is in position 4). Adding a phone number to the phonebook It is possible to add phone numbers to the phonebook just with a phone ring without sending a text message.
Page 28
Setting the operating mode It is possible to set the operating mode of the instrument (ON or OFF). The syntaxes of the commands to send are: TERMO ON TERMO OFF The phone number in the phonebook that sends the command will receive a text message informing of the thermostat status.
Page 29
Some examples: T0 DISABLED excludes the antifreeze temperature (therefore when the instrument is off, there is no regulation) T0 5.5 sets the antifreeze temperature to 5.5°C The phone number in the phonebook that sends the command will receive a text message confirmation.
Page 30
The phone number in the phonebook that sends the command will receive a text message confirmation: NIGHT=ON (-3C INI 22:10 END 6:30) To deactivate the night reduction mode: NIGHT OFF To activate the night reduction mode: NIGHT ON To change the reduction value (delta) without changing time: NIGHT 4 activates the reduction of 4°C compared to the setpoint without changing the previous set time slot Note: if the night reduction mode is set, the symbol “...
N SIM=3331234567 01.07.10 14:55:23 In this case, the writing “(reg)” is related to the measured temperature value of the internal probe and indicates the probe (if there are two probes) on which is performed the regulation. MANAGEMENT OF ALARMS The thermostat can be configured to send text message alarms to phone numbers in the phonebook.
Page 32
where: [recipient] indicates the phone number in the phonebook to send the alarm. Some examples: SEND ALARM EXTERNAL 1 3 4 sends a text message to phone numbers 1, 3, 4 in the phonebook in case of alarm on digital input SEND ALARM MAXIMUM 2 sends a text message to phone number 2 in the phonebook in case of alarm for exceeded temperature...
Page 33
Some examples: SET ALARM CONTACT OPEN 10 digital input alarm if the input of the thermostat stays open for about 10 seconds SET ALARM CONTACT CLOSED 30 digital input alarm if the input of the thermostat stays open for about 30 seconds Notes: the alarm return is immediate in correspondence with the contact status change.
Page 34
[delay] numerical value that indicates minutes of permanence after which the threshold [threshold] can be considered an alarm SET ALARM MAXIMUM restores the current configuration for the maximum threshold SET ALARM MINIMUM restores the current configuration for the minimum threshold Some examples: SET ALARM MINIMUM INT 12 2 30 generates a minimum alarm if the measured...
Page 35
Redirecting unrecognised messages If the thermostat receives a text message that is not recognised as a command, the text message is forwarded to a number in the phonebook. This function can be useful if the telephone operator sends informative messages to the SIM card inserted in the thermostat (for example lack or expiring credit).
Page 36
TERMO NUMBER [number] where [number] is the phone number of the SIM card inserted in the Thermo GSM. The Thermo GSM replies to the sender with the following type of message: TERMO NUMBER 3331234567 Manually If the number of the SIM card in the Thermo GSM is not specified, it is possible to synchronise time and date remotely.
BACKUP BATTERY The instrument has a backup battery that permits operation in case of power supply failure until it is completely discharged. The battery is recharged by Thermo GSM: the battery is completely recharged after about 24 hours of powering by mains supply.
Page 40