Introduction
The RT510TX thermostat will switch your heating system on or off, as needed, in accordance
with the time and temperature set by you. It can be used with the LG+5V integral plug-in
RF boiler module. The LG+5V boiler module 868MHz is a receiver with 5V DC to control ON/OFF of
Boiler or other heat system via the RF signal transmitted from the thermostat.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC
2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is
available on www.saluslegal.com
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect
your device before cleaning it with a dry cloth. This accessory must be fitted by a competent person, and
installation must comply with the guidance, standards and regulations applicable to the city, country or
state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Always isolate the AC Mains supply before installing or working on any components
that require 230 VAC 50Hz supply.
Box content
Desk Stand
RT510TX
LG+5V
2 x AA Alkaline
Quick Guide
2 x Fixing Screws
Batteries
LG+5V Installation
Blanking
Plate
Mechanical
Timer
i
When removing blanking plate, also remove visible thermostat link plug, do not remove
any internal link.
Ensure boiler is isolated and switched off.
1
2
Pull down control panel cover.
Remove existing mechanical timer /
3
blanking plate and unscrew from plate.
Reverse the procedure to install the
4
LG+5V.
5
Connect the electrical plug.
6
Push fit boiler control into housing.
The LG+5V is ready to be paired with your
7
thermostat.
LG+5V User Controls
LED - It will be on when the thermostat is demanding
heat.
SYNC Button - This is used only for pairing the RF
communications.
Mode Switch
ON – Boiler will be on continuous
AUTO – will follow time and temperature program in
the transmitter
OFF – Boiler is off
LG+5V Switch Position
The boiler receiver is OFF. When in this
1
mode, the boiler will not receive a signal
from the RF thermostat.
AUTO. RX will automatically receive the RF
2
signal from your compatible SALUS device
and control the module output so that it
switches the boiler accordingly.
MANUAL mode - Manual Override. When in
3
this mode, the boiler will be always turned
on and the LED indicator will also be lit
1
2
constantly.
RT510TX Button Functions
Key
Function
1. Press once to activate Frost Mode
2. Press for 3 seconds in order to activate Holiday Mode
+Hr
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function
Increase button
Decrease button
Select the clock or programme settings
SELECT
Press to confirm your settings
SET
1. Press once to enter/exit in Test Mode
2. Press for 3 seconds to enter/exit Pairing Mode
+
+
Press the buttons for 3 seconds to enter Installer Mode
SELECT
Press the buttons for 3 seconds to enter Clock Settings
+
SET
RT510TX Dip Switch Settings
The DIP Switches can be found on the rear of your thermostat.
Control feature
TPI
Span
Operation
When TPI is selected on DIP
When Span is selected
switch № 2, the DIP switch
on DIP switch № 2,
№ 1 is functional. You can
the DIP switch № 1 is
choose the Cycles Per Hour
not functional.
between a lower comfort
temperature accuracy of
level (6CPH) and a higher
your thermostat is set to
comfort level (9CPH).
± 0.25 °C.
Test the Pairing Process
i
During test pairing, boiler control should flash confirming pair. If not, please follow
Pairing Process.
+Hr
+Hr
TEST / PAIRING
SELECT
SET
i
When enter test pairing
mode, after a 10 minute
countdown the thermostat
will time out.
The LED will start flashing red.
Pairing Process
1
Press the SYNC button for 3
2
The LG+5V is ready to be paired
3
seconds until LED starts flashing.
with your thermostat.
3 Sec
Begin the pairing process
3
+Hr
+Hr
3 Sec
TEST / PAIRING
SELECT
SET
End the pairing process
4
+Hr
+Hr
3 Sec
TEST / PAIRING
SELECT
SET
i
Once the LED stops flashing, press the
Once paired please close the
The
TEST / PAIRING button for 3 sec.
boiler control panel.
SELECT
SET
TEST / PAIRING
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET

Advertisement

loading
Need help?

Need help?

Do you have a question about the RT510LG5V and is the answer not in the manual?

Questions and answers

Summary of Contents for Salus RT510LG5V

  • Page 1 LG+5V Installation from the RF thermostat. The LED will start flashing red. AUTO. RX will automatically receive the RF signal from your compatible SALUS device and control the module output so that it Pairing Process switches the boiler accordingly. Blanking MANUAL mode - Manual Override.
  • Page 2 Setting Time and Date Permanent Override Holiday Mode 3sec TEST / PAIRING TEST / PAIRING SELECT SELECT TEST / PAIRING TEST / PAIRING TEST / PAIRING SELECT SELECT TEST / PAIRING SELECT SELECT SELECT TEST / PAIRING SELECT TEST / PAIRING 3 Sec 3 Sec Press UP or DOWN to select the hour format...