Summary of Contents for Fujitsu PRIMERGY CX2560 M4
Page 1
Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY CX2550 M4 / CX2560 M4 / CX2570 M4 Server Node Upgrade and Maintenance Manual Edition March 2018...
All hardware and software names used are trademarks of their respective manufacturers. – The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.
Page 3
Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product.
Page 4
Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning.
Page 5
Version history Issue number Reason for update 0.9 / April 2017 Initial release 1.0 / May 2017 Final version 1.1 / July 2017 Final version 2.0 / August 2017 Update version 3.0 / November 2017 Update version 4.0 / March 2018 Update version Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 6
Upgrade and Maintenance Manual CX2550/60/70 M4...
Contents Introduction ......21 Notational conventions ....22 Before you start .
Page 8
Contents Shutting down the server node ....50 Removing the server node from the server enclosure ..51 Removing the GPGPU / SXM2 extension tray ..53 Installing the riser module .
Page 9
Contents 5.2.2 Verifying system information backup / restore ..83 5.2.3 Updating expansion card firmware ....83 5.2.4 Enabling Option ROM scan .
Introduction This Upgrade and Maintenance Manual provides instructions for the following procedures: Upgrading the server configuration by adding optional hardware ● components Upgrading the server configuration by replacing existing hardware ● components with superior ones. Replacing defective hardware components ● This manual focuses on on-site maintenance tasks.
Introduction Notational conventions The following notational conventions are used in this manual: indicates commands or menu items Text in italics indicates system output fixed font indicates text to be entered by the user semi-bold fixed font "Quotation marks" indicate names of chapters and terms that are being emphasized describes activities that must be performed in the order Ê...
Installing optional components The operating manual of your server gives an introduction to server features and provides an overview of available hardware options. Use the Fujitsu ServerView Suite management software to prepare hardware expansions. ServerView Suite documentation is available online at: http://manuals.ts.fujitsu.com For Japan: http://www.fujitsu.com/jp/products/computing/servers/primergy/manual/...
Page 24
For Japan: http://jp.fujitsu.com/platform/server/primergy/system/ Please contact your local Fujitsu customer service partner for details on how to order expansion kits or spare parts. Use the Fujitsu Illustrated Spares Catalog to identify the required spare part and obtain technical data and order information.
At the beginning of each procedure, the involved unit type is indicated by one of the symbols introduced in this section. Please ask your local Fujitsu service center for more detailed information. 2.1.1 Customer Replaceable Units (CRU)
Units as customer replaceable CSS components. For Japan, customer allows only upgrade. For upgrade units as customer replaceable, see: http://www.fujitsu.com/jp/products/computing/servers/primergy/ Upgrade and repair procedures involve shutting down and opening the server. CAUTION! The device may be seriously damaged or cause damage if it is opened without authorization or if repairs are attempted by unauthorized and untrained personnel.
Maintenance procedures involving Field Replaceable Units must be performed exclusively by Fujitsu service personnel or technicians trained by Fujitsu. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Components that are handled as Field Replaceable Units –...
Before you start Average task duration Average task duration: 10 minutes The average task duration including preliminary and concluding steps is indicated at the beginning of each procedure next to the procedure class. For an overview of steps taken into account for calculating the average task duration, see table 1 on page Step...
Before you start Tools you need at hand When preparing the maintenance task, ensure that all required tools are available according to the overview below. You will find a list of required tools at the beginning of each procedure. Screw driver / Screw Usage Type...
– Ensure to store all printed manuals enclosed with your server in a save place for future reference. – Unless stated otherwise, all manuals are available online at http://manuals.ts.fujitsu.com under x86 Servers. For Japan, please use the following address: http://www.fujitsu.com/jp/products/computing/servers/primergy/manual/...
"Safety Notes and Regulations" Important safety information, available manual online or as a printed copy " 安全上のご注意 " for Japan "FUJITSU Server PRIMERGY CX2550 M4/ CX2560 M4 / Available online CX2570 M4 Server Node Operating Manual" "D3853 BIOS Setup Utility for FUJITSU Server PRIMERGY CX2550 M4 Reference Manual"...
Table 3: Documentation you need at hand for the server node 2.4.2 Documents for the server enclosure Document Description "Quick Start Hardware - FUJITSU Server PRIMERGY Available online CX400 M4" leaflet "FUJITSU Server PRIMERGY CX400 M4 Server Enclosure" Available online...
Important information CAUTION! Before installing and starting up a server, please observe the safety instructions listed in the following section. This will help you to avoid making serious errors that could impair your health, damage the server and endanger the data base. Safety instructions The following safety instructions are also provided in the manual "Safety Notes and Regulations"...
Page 34
Important information Wait until the server has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the server if this requirement is not observed. Only transport the server in its original packaging or in packaging that ●...
Page 35
Important information The adequately shielded data cables must be used. ● All data and signal cables must have sufficient shielding. The use of cable type S/FTP Cat5 or higher is recommended. Use of unshielded or badly shielded cables may lead to increased emission of interference and/or reduced fault-tolerance of the device.
Page 36
Important information Only set screen resolutions and refresh rates that are specified in the ● operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center. Only valid for non hot-plug components ●...
Page 37
Important information The battery used in this server may present a fire or chemical burn hazard if ● mistreated. Do not disassemble, heat about 100 °C (212F), or incinerate the battery. Replace the lithium battery on the system board in accordance with the ●...
Page 38
Important information Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray ● roughly. Do not disassemble the optical disk drive. ● Before use, clean the optical disk tray using a soft, dry cloth. ● As a precaution, remove disks from the optical disk drive when the ●...
Page 39
Important information – Only insert disks in the drive when needed and remove them after use. – Store the disks in suitable sleeves. – Protect the disks from exposure to heat and direct sunlight. Laser information The optical disk drive complies with IEC 60825-1 laser class 1. CAUTION! The optical disk drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser...
Page 40
Important information Wear a suitable grounding cable that connects you to the external chassis ● of the server. Always hold ESD modules at the edges or at the points marked green (touch ● points). Do not touch any connectors or conduction paths on an ESD module. ●...
Important information Do not extend more than one server out of the rack simultaneously ● even if the tilt protection is in place. If several servers are simultaneously extended from the rack, there is a risk that the rack could tip over. See the safety information of the rack and the warning label.
Important information CE conformity :The system complies with the requirements of European Regulations. Find the CE declaration on certificate portal: https://sp.ts.fujitsu.com/sites/certificates/default.aspx To open the CE declaration applicable for your system, proceed as follows: Ê Select Industry Standard Servers. Ê Select your model, e.g. Rack server.
Consult the dealer or an experienced radio/TV technician for help. ● Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
Important information Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
Page 45
Further information can be found at: http://ts.fujitsu.com/recycling Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch, or at: http://ts.fujitsu.com/recycling Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 46
Important information Upgrade and Maintenance Manual CX2550/60/70 M4...
Basic hardware procedures Using diagnostics information Use the Fujitsu ServerView Suite management software to plan the upgrade or replacement of hardware components. See the following ServerView Suite topics: – Operation – Maintenance It is recommended to prepare local maintenance tasks using remote diagnostics procedures, see the "ServerView Suite Local Service Concept (LSC)"...
Basic hardware procedures Ê When using ServerView Operations Manager to toggle the ID indicator, choose Single System View and press the Locate button. Ê Remember to switch off the ID indicator after the maintenance task has been concluded successfully. 4.1.2 Determining the error class The Local Service Concept (LSC) allows you to identify defective server components.
Basic hardware procedures 4.1.2.2 Global Error indicator Ê Check the Global Error indicator on the front panel or I/O panel of the server (see section "Controls and indicators on the server node" on page 448). Ê For further diagnostics, proceed as follows: –...
Basic hardware procedures Shutting down the server node CAUTION! For further safety information, see chapter "Important information" on page This step is only required when upgrading or replacing non-hot-plug components. Ê Inform the system administrator that the server node will be shut down and put offline.
Basic hardware procedures Removing the server node from the server enclosure CAUTION! Shut down the server node and disconnect all external cables. ● Follow the safety instructions in the chapter "Important information" ● on page The server node bay must not be left open for more than 60 minutes. ●...
Page 52
Basic hardware procedures CAUTION If the server node is difficult to pull out of the bay, push the server node, and then pull the server node while pushing the server node to the left side. Figure 2: Removing the server node Upgrade and Maintenance Manual CX2550/60/70 M4...
Basic hardware procedures Removing the GPGPU / SXM2 extension tray When you use CX2570(SXM) M4 (liquid cooling type 2), perform the following steps: Figure 3: Removing the SXM2 extension tray – Remove the screws of the SXM riser card (L) type 2 (see circles). Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 54
Basic hardware procedures This section describes how to remove the GPGPU extension tray. The SXM2 extension tray is removed in the same way. Figure 4: Removing the GPGPU extension tray (A) – Remove the screws (see circles). Figure 5: Removing the GPGPU extension tray (B) –...
Basic hardware procedures Installing the riser module Figure 6: Installing the riser module (A) Ê Insert the bolt in the chassis recess (see circle). Ê Lower the riser module straight on and plug the riser in the slot. Figure 7: Installing the riser module (B) Ê...
Page 56
Basic hardware procedures Check that the hook of the riser module does fit into the hole of node tray securely. Figure 8: Installing the riser module (B) This is the good case. This is the bad case. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 57
Basic hardware procedures Install the riser module on the right side accordingly. Figure 9: Installing the gasket between the riser modules Ê Verify the cutout and plug the gasket between the riser modules as shown. Upgrade and Maintenance Manual CX2550/60/70 M4...
Basic hardware procedures Removing the riser module Figure 10: Removing the gasket between the riser modules Ê Remove the gasket between the riser modules (see arrow). Figure 11: Removing the riser module Lift up the riser module straight on and remove the riser from the slot. Ê...
Basic hardware procedures Installing the dummy riser module If no riser modules are installed the front of riser module area must be fitted with dummy riser module. Figure 12: dummy riser module Figure 13: Installing the dummy riser module Ê Shift the dummy riser module in a vertical motion in front of the riser module area (1).
Basic hardware procedures Removing the dummy riser module Figure 14: Removing the dummy riser module Ê Pull up the dummy riser module and remove it from the chassis in a vertical motion. Upgrade and Maintenance Manual CX2550/60/70 M4...
Basic hardware procedures Mounting a slot cover to the riser module Figure 15: Mounting a slot cover to the riser module Ê Insert a slot cover into the riser module front opening (see arrow). Ê Secure the slot cover to the riser module with a screw (see circle). 4.10 Removing the slot cover from the riser module...
Basic hardware procedures 4.11 Installing the OCP dummy module Figure 17: Installing the OCP dummy module Ê Insert the OCP dummy module in front of the OCP slot. Make sure the hooks on both sides of the OCP dummy module are inserted in the recesses of the chassis (see circles).
Basic hardware procedures 4.13 Removing the memory slot air duct (Air cooling only) Figure 19: Removing the memory slot air duct – Pull up the air duct in a vertical motion and remove it from the chassis. Upgrade and Maintenance Manual CX2550/60/70 M4...
Basic hardware procedures 4.14 Installing the memory slot air duct (Air cooling only) Figure 20: Installing the memory slot air duct – Place the air duct in the chassis as shown. Upgrade and Maintenance Manual CX2550/60/70 M4...
Basic hardware procedures 4.15 Installing the GPGPU / SXM2 extension tray This section describes how to install the GPGPU extension tray. The SXM2 extension tray is installed in the same way. Figure 21: Installing the GPGPU extension tray (A) – Plug the GPGPU extension tray hooks in the recesses of the CX2570 chassis (1).
Page 66
Basic hardware procedures Figure 22: Installing the GPGPU extension tray (B) – Secure the GPGPU extension tray with 2 screws (see circles). When you use CX2570(SXM) M4 (liquid cooling type 2), perform the following steps: Figure 23: Installing the SXM2 extension tray –...
Basic hardware procedures 4.16 Installing the server node in the server enclosure CAUTION! Follow the safety instructions in the chapter "Important information" ● on page Ê Remove the gasket of the lower server node and keep it for later use. Ê...
Page 68
Basic hardware procedures Ê Stick the label that describes the product name and the serial number of the server node on the ID card. – The label that describes the product name and serial number is included in the delivery pack of the server node. –...
Basic hardware procedures 4.17 Switching on the server node CAUTION! For further safety information, see chapter "Important information" on page Ê If applicable, connect all external cables to the server node. Ê Press the On/Off button either on the server node or on the corresponding front panel to start up the server node.
Basic software procedures Starting the maintenance task 5.1.1 Suspending BitLocker functionality BitLocker Drive Encryption provides protection for operating system and data drives by encrypting the contents and requiring users to authenticate their credentials to access the information. In the scenario described here, BitLocker uses the compatible Trusted Platform Module (TPM) to detect if the computer's startup process has been modified from its original state.
Page 72
BitLocker setup wizard, it may be necessary to modify the BitLocker Group Policy settings. For more information on how to suspend BitLocker drive encryption, see the Microsoft TechNet library at http://technet.microsoft.com/library/cc731549.aspx. For more information, see the Fujitsu web pages. Upgrade and Maintenance Manual CX2550/60/70 M4...
Basic software procedures 5.1.2 Disabling the boot watchdog functionality of ServerView Operations Manager The ServerView Operations Manager boot watchdog determines whether the server boots within a preset time frame. If the watchdog timer expires, the system will automatically reboot. 5.1.2.1 Viewing boot watchdog settings Viewing boot watchdog settings in the BIOS Ê...
Basic software procedures For more information, see the "ServerView Operations Manager - Server Management" user guide. 5.1.2.2 Configuring boot watchdog settings If the system is to be started from removable boot media for firmware upgrade purposes, the Boot watchdog needs to be disabled before starting maintenance task.
For Japan: Please contact Fujitsu support, if "forcible" tape ejection is necessary. Fujitsu does not assume responsibility for any damage to the tape drive, the data cartridge/tape or for the loss of any data resulting from manual tape extraction procedures.
Basic software procedures Ê The Network Interfaces (Summary) overview shows all configured LAN teams and their components. Choose a LAN team to display further details: – LAN Team Properties: Properties of the selected LAN team – LAN Team Statistics: Available statistics about the selected LAN team For more detailed information, refer to the "ServerView Operations Manager - Server Management"...
Updating or recovering the system board BIOS Flash BIOS update For Japan, follow the instructions provided separately. For Fujitsu PRIMERGY Servers you have basically the choice to select between online flash and offline flash: Online flash update: Flash BIOS update is processed while operating system is running. The system is accessible via network, and Flash BIOS update might be controlled online by administrator.
Page 78
Basic software procedures Ê Select your system via Select Product or look under Product Search by Serial- /Identnumber for your system. Ê Select your operating system. Ê Select Flash-BIOS. For Online Flash – Select Flash BIOS <System> (ASP for Windows/Linux) –...
Page 79
Basic software procedures For Linux: Ê Call "sh <ASP-name>.scexe [options ..]" from a command line interface. Get more information about possible options by calling "<ASP-name>.scexe -- help". BIOS updates always require a closing system reboot. Offline Flash: Flash BIOS Update with an USB stick You need an USB stick on which the BIOS update files will be stored.
Page 80
Basic software procedures Flash Memory Recovery Mode For Japan, follow the instructions provided separately. Ê Prepare a bootable USB stick, see section "Flash BIOS update" on page Ê Switch off the system and disconnect the power plug. Ê Open the chassis and switch on "Recovery" (BIOS-RCV) using the jumper / DIP switch (SW4-5) on the system board.
Basic software procedures 5.2.1.2 Updating or recovering the iRMC iRMC flash procedure For Japan, follow the instructions provided separately. Ê Prepare a USB stick including the bootable iRMC firmware update image. Ê Connect the USB stick to the USB port. Ensure that only the USB device with the iRMC firmware is connected to the USB port.
Page 82
Ê Press the Power On/Off button. The system starts the POST process. In iRMC recovery mode, the “FUJITSU” logo does not show up. Ê The system will detect the USB stick.
After replacing the expansion card, it is essential to upgrade the firmware to the latest version without connecting any storage devices. The latest expansion card firmware version is available from the Fujitsu support web pages at: http://ts.fujitsu.com/support/ Upgrade and Maintenance Manual...
Page 84
"Local System Update for PRIMERGY Servers" user guide Using the flash tool The latest firmware files are available as ASPs (Autonomous Support Packages) for Windows or as DOS tools from the Fujitsu support web pages at: http://ts.fujitsu.com/support/ For Japan: http://www.fujitsu.com/jp/products/computing/servers/primergy/downloads/ Ê...
Basic software procedures Ê Select the desired file and click Download for further instructions. 5.2.4 Enabling Option ROM scan In order to configure an expansion card that has been installed or replaced, the Option ROM of the card has to be enabled in the BIOS. The firmware of the card is called by the BIOS upon reboot and can be entered and configured.
Basic software procedures 5.2.5 Resetting the boot retry counter The boot retry counter is decremented from its preset value every time the POST watchdog initiates a system reboot. When the value has reached ’0’, the system will shut down and power off. 5.2.5.1 Viewing the boot retry counter The current boot retry counter status is available in the BIOS:...
Page 87
Basic software procedures Resetting the boot retry counter using the ServerView Operations Manager Ê In the ServerView Operations Manager Administration view, select Server Configuration. Ê If more than one server is managed in SVOM, select the target server and click Next. Ê...
Basic software procedures 5.2.6 Enabling SVOM boot watchdog functionality If ServerView Operations Manager boot watchdog functionality has been disabled for firmware upgrade purposes (see section "Disabling the boot watchdog functionality of ServerView Operations Manager" on page 73), it has to be re-enabled to complete the maintenance task. Timer settings can be configured in the BIOS or using the ServerView iRMC web frontend: Configuring boot watchdog settings in the BIOS...
Basic software procedures 5.2.7 Enabling replaced components in the BIOS When a CPU, an expansion card, or a memory module fails, the defective component will be set to Disabled or Failed in the BIOS. The server will then reboot with only the intact hardware components remaining in the system configuration.
More information on suitable backup software solutions and related documentation is available from the Fujitsu web pages. Re-enabling backup drives If a backup drive has been disabled or deleted from the backup software drive list as described in section "Removing backup and optical disk media"...
Page 91
Basic software procedures Ê Save your changes (if applicable) and exit the BIOS. For more information on how to access the BIOS and modify settings, see the corresponding BIOS Setup Utility reference manual. Upgrade and Maintenance Manual CX2550/60/70 M4...
Basic software procedures 5.2.10 Verifying the system time settings This task only applies to Linux and VMware environments. After the system board has been replaced, the system time is set automatically. By default, the RTC (Real Time Clock) time standard is set as the local time. If a Linux/VMware OS is used and the hardware clock has been configured as UTC (Universal Time, Coordinated) in the operating system, the BMC local time may not be mapped correctly.
Basic software procedures 5.2.11 Viewing and clearing the System Event Log (SEL) 5.2.11.1 Viewing the SEL You can view the System Event Log (SEL) using the ServerView Operations Manager or the ServerView iRMC web interface: Viewing the SEL in ServerView Operations Manager Ê...
Basic software procedures Viewing the SEL using the iRMC web interface Ê Log in to the ServerView iRMC web interface. Ê Open the Logs menu. Ê Click System Event Log to open the System Event Log page. All events concerning the system are displayed in a table in the Event Log Content group.
Page 95
Basic software procedures In order to prevent communication problems, it is necessary to update the changed MAC address stored in the related ifcfg-eth<x> definition file. To update the MAC address, proceed as follows: Procedures may differ depending on your Linux/VMware OS or the definition file on the client system.
Ê Select the system volume, and click Resume Protection. For more information on how to resume BitLocker drive encryption, see the Microsoft TechNet library at http://technet.microsoft.com/library/cc731549.aspx. For more information, see the Fujitsu web pages. Upgrade and Maintenance Manual CX2550/60/70 M4...
Basic software procedures 5.2.14 Performing a RAID array rebuild After replacing an HDD that has been combined into a RAID array, RAID rebuild will be performed completely unattended as a background process. Ê Ensure that the RAID array rebuild has started normally. Wait until the progress bar has reached at least one percent.
Basic software procedures 5.2.15.1 Looking up MAC addresses Ê Log in to the ServerView iRMC web interface. Ê Open the Settings menu. Ê Open the Baseboard Management Controlller page. Ê In the Network Interface group, you will find more information on each network controller in the managed PRIMERGY server, including its MAC address.
ServerView Installation Manager, system data needs to be complete and correct. The tool and further instructions are available to maintenance personnel from the Fujitsu Technology Solutions Extranet: https://partners.ts.fujitsu.com/com/service/ps/Servers/PRIMERGY/ Ê Select your PRIMERGY system from the main area of the page.
Basic software procedures 5.2.17 Configuring LAN teaming Use ServerView Operations Manager to obtain more information on existing LAN teams: Ê In ServerView Operations Manager Single System View select System Status from the Information/Operation menu. Ê Under Network Interfaces select LAN Teaming. Ê...
Basic software procedures 5.2.18 Switching off the ID indicator Press the ID button on the front panel, or use the iRMC web interface or ServerView Operations Manager to switch off the ID indicator after the maintenance task has been concluded successfully. For more information, see section "Locating the defective server"...
Page 102
Ê After the fan test is complete, restore the time setting to its initial value and click Save Page. In case of maintenance done by Fujitsu engineers in Japan: Executing the fan test via Chassis ID Prom Tool Please follow the instructions provided separately.
Using ServerView Maintenance Tools (Windows only) Ê Launch the ServerView Maintenance Tools: – Windows Server 2008 R2 and below: Start > (All) Programs > Fujitsu > ServerView Suite > Agents > Maintenance Tools – Windows Server 2012 and above: Start > Apps > Fujitsu > Maintenance Tools Ê...
If an old version of the ServerView RAID Manager is used, the SSD life monitoring function does not work correctly after replacement. Please always use the latest version of the ServerView RAID Manager. http://ts.fujitsu.com/support/ (for http://www.fujitsu.com/jp/products/computing/servers/primergy/downloads/ Japan)
Expansion cards and OCP mezzanine cards Safety notes CAUTION! Do not damage or modify internal cables or devices. Doing so may ● cause a device failure, fire, or electric shock. Devices and components inside the server node remain hot after ●...
The PCIe slot / OCP slot population order lists in this section may be changed due to new controllers. For the latest information on supported expansion cards, refer your server’s hardware configurator available online at the following address: http://ts.fujitsu.com/products/standard_servers/index.htm for Japan: http://jp.fujitsu.com/platform/server/primergy/system/ 6.1.1 CX2550 M4 The server node can be flexibly expanded with two expansion cards PCIe 3.0...
Page 107
Expansion cards and OCP mezzanine cards Pos. Slot Type Mechanical Electrical connector connector PCIe slot 1 (to CPU2) PCI Gen3 OCP connector Type A PCI Gen3 OCP connector Type B PCI Gen3 PCIe slot 1 (to CPU1) PCI Gen3 PCIe slot 2 (to CPU1) PCI Gen3 CX2550 M4 PCIe Slot / OCP slot population order (air cooling) Upgrade and Maintenance Manual...
Page 108
Expansion cards and OCP mezzanine cards CX2550 M4 PCIe Slot / OCP slot population order (liquid cooling type 1) Figure 26: CX2550 M4 PCIe slot population for liquid cooling type 1 Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 109
Expansion cards and OCP mezzanine cards CX2550 M4 PCIe Slot / OCP slot population order (liquid cooling type 2) Figure 27: CX2550 M4 PCIe slot population for liquid cooling type 2 Upgrade and Maintenance Manual CX2550/60/70 M4...
Expansion cards and OCP mezzanine cards 6.1.2 CX2560 M4 / CX2570 M4 These server nodes can be flexibly expanded with up to two expansion cards PCIe 3.0 x16 (via riser module) and one OCP PCIe x16 mezzanine card. The CX2570 M4 server node additional uses two PCIe Gen3 x16 connectors to support a GPGPU extension tray or an SXM2 extension tray.
Page 111
Expansion cards and OCP mezzanine cards CX2570 M4 Pos. Slot Type Mechanical Electrical connector connector PCIe connector for GPGPU / SXM tray (CPU1) or PCIe Slot 2 PCI Gen3 (CPU1) PCIe connector for GPGPU / PCI Gen3 SXM tray (CPU2) PCIe connector for GPGPU / PCI Gen3 SXM tray (CPU1)
Page 112
Expansion cards and OCP mezzanine cards CX2560 M4 PCIe Slot / OCP slot population order (air cooling) Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 113
Expansion cards and OCP mezzanine cards CX2570 M4 PCIe Slot / OCP slot population order (air cooling) Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 114
Expansion cards and OCP mezzanine cards Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 115
Expansion cards and OCP mezzanine cards CX2560 M4 PCIe Slot / OCP slot population order (liquid cooling type 1) Figure 29: CX2560 M4 PCIe slot population for liquid cooling type 1 Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 116
Expansion cards and OCP mezzanine cards CX2570(SXM) M4 PCIe Slot / OCP slot population order (liquid cooling type 1) Figure 30: CX2570(SXM) M4 PCIe Slot / OCP slot population order (liquid cooling type 1) Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 117
Expansion cards and OCP mezzanine cards CX2570(SXM) M4 PCIe Slot / OCP slot population order (liquid cooling type 2) Figure 31: CX2570(SXM) M4 PCIe Slot / OCP slot population order (liquid cooling type 2) Upgrade and Maintenance Manual CX2550/60/70 M4...
Expansion cards and OCP mezzanine cards Expansion cards in the riser module Safety notes CAUTION! Do not damage or modify internal cables or devices. Doing so may ● cause a device failure, fire, or electric shock. Devices and components inside the server remain hot after ●...
Expansion cards and OCP mezzanine cards 6.2.1.2 Mounting a controller to the riser module Figure 32: Mounting a controller to the riser module "Removing the slot cover from the riser module" on page 61 (if applicable) Ê Ê If applicable, install a TFM on the expansion card, see section "Installing a TFM"...
Expansion cards and OCP mezzanine cards This is the good case. This is the bad case. Ê If applicable, install SFP+ transceiver modules on the new expansion card, see section "Installing SFP+ transceiver modules" on page 172. 6.2.1.3 Connecting cables to the expansion card Ê...
Expansion cards and OCP mezzanine cards 6.2.2 Removing expansion cards Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: Phillips PH2 / (+) No. 2 screw driver 6.2.2.1 Preliminary steps Perform the following procedures: Ê Locate the desired server node with the ID button. "Shutting down the server node"...
Expansion cards and OCP mezzanine cards 6.2.2.2 Removing a controller from the riser module Figure 33: Removing a controller from the riser module Ê Remove the screw (1). Ê If applicable, disconnect internal cables to the expansion card. Ê Pull the controller out of the riser card connector (2). Ê...
Expansion cards and OCP mezzanine cards 6.2.3 Replacing expansion cards Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: Phillips PH2 / (+) No. 2 screw driver Note on network settings recovery When replacing network controllers or the system board, network configuration settings in the operating system will be lost and replaced by default values.
Expansion cards and OCP mezzanine cards Ê If the slot bracket on the defective expansion card is to be reused, remove it from the board, see section "Mounting expansion card slot brackets" on page 165. 6.2.3.3 Installing an expansion card Ê...
Page 126
Expansion cards and OCP mezzanine cards Ê Inform the customer about changed WWN and MAC addresses. For further information, see section "Looking up changed MAC/WWN addresses" on page By replacing expansion cards WWN (World Wide Name) and MAC (Media Access Control) addresses will change. Upgrade and Maintenance Manual CX2550/60/70 M4...
Expansion cards and OCP mezzanine cards Expansion cards in the SXM2 riser card (L) type 2 Safety notes CAUTION! Do not damage or modify internal cables or devices. Doing so may ● cause a device failure, fire, or electric shock. Devices and components inside the server remain hot after ●...
Expansion cards and OCP mezzanine cards 6.3.1 Installing expansion cards Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: Phillips PH2 / (+) No. 2 screw driver 6.3.1.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
Page 129
Expansion cards and OCP mezzanine cards 6.3.1.2 Mounting an expansion card to SXM2 riser card (L) type 2 Figure 34: Mounting a controller to the riser module Ê Insert the expansion card to the PCI cage. Figure 35: Mounting a controller to the riser module Ê...
Expansion cards and OCP mezzanine cards Figure 36: Mounting a controller to the riser module Ê Fasten the expansion card and the gasket with one screw (1). Ê Plug the expansion card into the SMX2 riser (L) type 2 connector. 6.3.1.3 Concluding steps Perform the following procedures:...
Expansion cards and OCP mezzanine cards "Controls and indicators on the server node" on page 448 Ê "Updating expansion card firmware" on page 83 (if applicable) Ê "After replacing/upgrading LAN controllers" on page 100 (if applicable) Ê 6.3.2 Removing expansion cards Upgrade and Repair Unit Hardware: 5 minutes (URU)
Expansion cards and OCP mezzanine cards 6.3.2.2 Removing a controller from the riser module Figure 37: Removing a controller from the riser module Ê Pull the expansion card out of the riser card connector. Ê Remove the screw (1). Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 133
Expansion cards and OCP mezzanine cards Figure 38: Removing a controller from the riser module Ê Remove the gasket from the PCI cage. Figure 39: Removing a controller from the riser module Ê Eject the expansion card from the PCI cage. Upgrade and Maintenance Manual CX2550/60/70 M4...
Expansion cards and OCP mezzanine cards 6.3.2.3 Concluding steps Perform the following procedures: "Installing the SXM2 riser (L) type 2" on page 412 Ê "Installing the GPGPU / SXM2 extension tray" on page 65 Ê "Installing the server node in the server enclosure" on page 67 Ê...
Expansion cards and OCP mezzanine cards 6.3.3 Replacing expansion cards Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: Phillips PH2 / (+) No. 2 screw driver Note on network settings recovery When replacing network controllers or the system board, network configuration settings in the operating system will be lost and replaced by default values.
Expansion cards and OCP mezzanine cards Ê If the slot bracket on the defective expansion card is to be reused, remove it from the board, see section "Mounting expansion card slot brackets" on page 165. 6.3.3.3 Installing an expansion card Ê...
Page 137
Expansion cards and OCP mezzanine cards Ê Inform the customer about changed WWN and MAC addresses. For further information, see section "Looking up changed MAC/WWN addresses" on page By replacing expansion cards WWN (World Wide Name) and MAC (Media Access Control) addresses will change. Upgrade and Maintenance Manual CX2550/60/70 M4...
Expansion cards and OCP mezzanine cards Backup Unit 6.4.1 Basic information The Flash Backup Unit (FBU) backs up the memory contents of the connected SAS RAID controller in the event of a power failure. FBU is supported only by CX2560 M4 and CX2570 M4 with air cooling. Figure 40: FBU mounting position Figure 41: FBU Upgrade and Maintenance Manual...
Expansion cards and OCP mezzanine cards 6.4.2.1 Preliminary steps "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 Ê Locate the desired server node with the ID button. "Shutting down the server node" on page 50 Ê...
Page 141
Expansion cards and OCP mezzanine cards Figure 44: Mounting the TFM (A) Ê Fit the two spacer bolts on the SAS RAID controller and secure each with a screw from the TFM kit. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 142
Expansion cards and OCP mezzanine cards Figure 45: Mounting the TFM (B) Ê Attach the TFM to the RAID controller. Ê Secure the TFM on the spacer bolts with two screws from the TFM kit. Figure 46: Mounting the TFM (C) Ê...
Expansion cards and OCP mezzanine cards 6.4.2.3 Installing the FBU Figure 47: Installing the FBU holder Ê Install the FBU holder on the system board as shown. Figure 48: Inserting the FBU (The mounting direction of the FBU is applicable for PRAID EP400i/EP420i/EP420e in CX2560 M4 and PRAID EP520i/540i/580i in CX2570 M4) Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 144
Expansion cards and OCP mezzanine cards Ê At a slight angle, fit the FBU under the retaining bracket of the FBU holder as shown (1). Ê Bend the other bracket outwards (2). Ê Push in the FBU until it locks in place (3). Ê...
Page 145
Expansion cards and OCP mezzanine cards PRAID EP400i/EP420i/EP420e in CX2570 M4 Figure 50: Reverse FBU mounting direction Location of the FBU connector Figure 51: FBU connector For both mounting directions, the FBU connector is located under the FBU holder (see circle). Upgrade and Maintenance Manual CX2550/60/70 M4...
Expansion cards and OCP mezzanine cards 6.4.2.4 Cabling of the FBU Figure 52: Routing the FBU cable Ê Insert the FBU cable into the gap between the heat sink and DIMM module, see marking. Figure 53: Connecting the FBU cable to the RAID controller Ê...
Page 147
Expansion cards and OCP mezzanine cards CX2560 M4 with PRAID EP400i/EP420i/EP420e and PRAID EP520i/540i/580i Figure 54: Routing FBU and SAS cables Ê Route the SAS cable (1) and the FBU cable (2) as shown. CX2570 M4 with PRAID EP400i/EP420i/EP420e Figure 55: Routing the FBU and SAS cables Ê...
Expansion cards and OCP mezzanine cards CX2570 M4 with PRAID EP520i/540i/580i Figure 56: Routing the FBU and SAS cables Ê Route the SAS cable (1) and the FBU cable (2) as shown. 6.4.2.5 Concluding steps Perform the following procedures: "Installing the riser module" on page 55 Ê...
Expansion cards and OCP mezzanine cards 6.4.3 Removing the FBU Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: tool-less CAUTION! Do not throw backup units into the trash can. Batteries must be disposed of in accordance with local regulations concerning special waste. For further safety information, see section "Environmental protection"...
Expansion cards and OCP mezzanine cards 6.4.3.2 Removing the FBU Figure 57: Removing the FBU from the holder Ê Bend the other bracket outwards (2). Ê Lift the FBU from the holder. Figure 58: Disconnecting the FBU cable Ê Disconnect the FBU cable from the RAID controller (see circle). Upgrade and Maintenance Manual CX2550/60/70 M4...
Expansion cards and OCP mezzanine cards 6.4.3.3 Concluding steps Perform the following procedures: "Installing the riser module" on page 55 Ê "Installing the memory slot air duct (Air cooling only)" on page 64 Ê "Installing the server node in the server enclosure" on page 67 Ê...
Expansion cards and OCP mezzanine cards 6.4.4 Replacing the FBU Upgrade and Repair Unit Hardware: 10 minutes (URU) Tools: tool-less CAUTION! Do not throw battery backup units into the trash can. Batteries must be disposed of in accordance with local regulations concerning special waste.
Expansion cards and OCP mezzanine cards 6.4.4.2 Removing the FBU "Removing the FBU" on page 153 Ê 6.4.4.3 Installing the new FBU "Installing the FBU" on page 139 Ê 6.4.4.4 Concluding steps Perform the following procedures: "Installing the riser module" on page 55 Ê...
Expansion cards and OCP mezzanine cards – Disconnect the SAS cables from the SAS RAID controller. – Remove the SAS RAID controller from its slot, see section "Removing expansion cards" on page 122. 6.4.5.2 Removing the TFM Figure 59: Disconnecting the FBU adapter cable from the TFM Ê...
Expansion cards and OCP mezzanine cards 6.4.5.3 Installing the new TFM Ê Install the TFM onto the existing TFM spacer bolts, see section "Installing a TFM" on page 140. 6.4.5.4 Concluding steps Ê Install the SAS RAID controller, see section "Mounting a controller to the riser module"...
Expansion cards and OCP mezzanine cards Riser card CAUTION! Follow the safety instructions in chapter "Important information" on page 6.5.1 Replacing the riser card Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: Hexagonal socket SW6 6.5.1.1 Preliminary steps Perform the following procedures: Ê...
Expansion cards and OCP mezzanine cards 6.5.1.2 Replacing the riser card Figure 61: Replacing the riser card The riser module consists of the riser metal bracket (1) and the riser card (2). The riser card is connected to the riser metal bracket with two screws (see circles).
Expansion cards and OCP mezzanine cards OCP mezzanine cards Safety notes CAUTION! Do not damage or modify internal cables or devices. Doing so may ● cause a device failure, fire, or electric shock. Devices and components inside the server remain hot after ●...
Expansion cards and OCP mezzanine cards 6.6.1.2 Installing the OCP mezzanine card Ê Remove the OCP dummy module from the chassis. Figure 62: Installing an OCP mezzanine card Ê Plug the controller on the four guide pins (see circles). Make sure that the card engages under the green hooks. Ê...
Expansion cards and OCP mezzanine cards 6.6.2 Removing the OCP mezzanine card Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: Tool-less 6.6.2.1 Preliminary steps Perform the following procedures: Ê Locate the desired server node with the ID button. "Shutting down the server node" on page 50 Ê...
Expansion cards and OCP mezzanine cards 6.6.2.2 Removing the OCP mezzanine card Figure 63: Removing the OCP mezzanine card Ê Disengage the OCP mezzanine card from the hooks (see circle) and remove it from the guide pins. "Installing the OCP dummy module" on page 62 (if applicable) Ê...
Expansion cards and OCP mezzanine cards 6.6.3 Replacing OCP mezzanine cards Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: Tool-less Note on network settings recovery When replacing network controllers or the system board, network configuration settings in the operating system will be lost and replaced by default values.
Expansion cards and OCP mezzanine cards CX2550 M4 / CX2560 M4 / CX2570 M4 server nodes require special OCP mezzanine card slot brackets. Therefore the general slot brackets of the spare part OCP mezzanine cards must be replaced with the slot brackets of the defective OCP mezzanine card. 6.6.3.3 Installing an OCP mezzanine card Ê...
Expansion cards and OCP mezzanine cards Additional tasks This section provides additional expansion card related information on how to install slot brackets and SFP+ transceiver modules. For further instructions regarding controller settings, see the accompanying documentation. 6.7.1 Mounting expansion card slot brackets Upgrade and Repair Unit Hardware: 5 minutes (URU)
Expansion cards and OCP mezzanine cards 6.7.1.2 Network adapter The figure below shows an example. Figure 64: Placing the slot bracket Ê Place the controller on the mounting tabs on the slot bracket (1). Ê Carefully shift the slot bracket towards the controller until the plug shells engage with the cut-outs in the I/O panel (2).
Page 167
Expansion cards and OCP mezzanine cards Figure 65: Fastening the slot bracket Ê Fasten the slot bracket to the controller with two M3 x 4.5 mm screws. Figure 66: Assembled network adapter Upgrade and Maintenance Manual CX2550/60/70 M4...
Expansion cards and OCP mezzanine cards 6.7.2 Installing OCP mezzanine card slot brackets Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: Phillips PH2 / (+) No. 2 screw driver 6.7.2.1 General instructions Ê Place the controller on the mounting tabs on the slot bracket. Ê...
Expansion cards and OCP mezzanine cards 6.7.2.2 OCP mezzanine card The OCP mezzanine card figures show an example. Figure 67: Placing the slot bracket - OCP mezzanine card Ê Carefully shift the slot bracket towards the OCP mezzanine card until the plug shells engage with the cut-outs in the slot bracket connector panel.
Page 170
Expansion cards and OCP mezzanine cards Figure 68: Fastening the slot bracket - OCP mezzanine card Ê Fasten the slot bracket to the controller with one M3 x 4.5 mm screw (see circle). CAUTION! There are OCP mezzanine cards without screws depending on the type.
Expansion cards and OCP mezzanine cards Figure 71: Removing the OCP mezzanine card slot bracket (B) Ê Lift the bracket a little bit so that the metal pin of the bracket disengages from the recess of OCP mezzanine card (see circle). Ê...
Page 173
Expansion cards and OCP mezzanine cards Preparing the SFP+ transceiver module Figure 72: Removing the protective optical port plug Ê Remove the SFP+ transceiver module from its protective packaging. Ê Remove the optical port plug from the new / additional SFP+ transceiver module.
Page 174
Expansion cards and OCP mezzanine cards Figure 73: Unlatching the locking bail Ê Carefully unlatch and fold down the locking bail on the SFP+ transceiver module. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 175
Expansion cards and OCP mezzanine cards Inserting the SFP+ transceiver module Figure 74: Inserting the SFP+ transceiver module Ê Insert and slide the SFP+ transceiver module into the socket connector as far as it will go. If only one slot is equipped with a SFP+ transceiver module, use the primary right connector as shown.
Page 176
Expansion cards and OCP mezzanine cards Figure 75: Latching the locking bail Ê Carefully fold up and latch the locking bail. Figure 76: Attaching the protective optical port plug Ê If the SFP+ transceiver module is not immediately connected to an LC connector, attach the protective optical port plug to the transceiver optical bores.
Page 177
Expansion cards and OCP mezzanine cards Installing the secondary SFP+ transceiver module Figure 77: Installing the secondary SFP+ transceiver module Ê If applicable, install the secondary SFP+ transceiver module accordingly. Upgrade and Maintenance Manual CX2550/60/70 M4...
Expansion cards and OCP mezzanine cards 6.7.4.2 Removing an SFP+ transceiver module Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: tool-less Figure 78: Removing the protective optical port plug Ê If present, remove the protective optical port plug from the SFP+ transceiver module.
Page 179
Expansion cards and OCP mezzanine cards Figure 79: Unlatching the locking bail Ê Carefully unlatch and fold down the locking bail on the SFP+ transceiver module to eject the transceiver from the socket connector. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 180
Expansion cards and OCP mezzanine cards Figure 80: Removing the SFP+ transceiver Ê Pull the SFP+ transceiver module out of its socket connector. Ê Reattach the protective optical port plug to the transceiver optical bores. Place the removed SFP+ transceiver module in an antistatic bag or other protective environment.
Main memory Safety notes CAUTION! Do not install unsupported third party memory modules. For further ● information on supported memory modules, see section "Basic information" on page 184. Memory modules remain hot after shutdown. Wait for components to ● cool down before installing or removing memory modules to prevent burns.
Main memory Basic information – Each CPU offers 8 slots for DDR4 memory modules. – Supported memory modules: RDIMM with ECC, LRDIMM, 3DS-LRDIMM and AEP (Apache Pass) DIMM – Mixing of LRDIMM with RDIMM is not allowed. – Unbuffered DIMMs are not supported. –...
Main memory 7.1.1 Memory sequence – Populate memory slot 1 / channel A (DIMM-1A) first. – Within the 6 channels, memory slot 1 must be populated prior to slot 2. – If memory modules with different capacities are used: – Install modules with higher capacities first. –...
Main memory 7.1.3 Operation modes Normal mode (CX2550, CX2560, CX2570) CPU 1 CPU2 channel DIMM # DIMMS 1 CPU populated 2 CPUs populated Performance channel mode (CX2550, CX2560, CX2570) CPU 1 CPU2 channel DIMM # DIMMS 1 CPU populated 2 CPUs populated Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 188
Main memory Rank sparing mode (CX2560 M4, CX2570 M4) With CX2560 M4 and CX2570 M4, single rank DIMM is not allowed for population. CPU 1 CPU2 channel DIMM # DIMMS 1 CPU populated 2 CPUs populated Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 189
Main memory Mirrored channel mode (CX2560 / CX2570) CPU 1 CPU2 channel DIMM # DIMMS 1 CPU populated 2 CPUs populated Upgrade and Maintenance Manual CX2550/60/70 M4...
Main memory Installing memory modules If liquid cooling kit is installed, first prepare the memory modules, see section "Memory module cooling pads for Liquid Cooling (LC)" on page 198. Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: tool-less 7.2.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations...
Main memory 7.2.2 Installing a memory module Figure 83: Installing memory modules (A) Ê Press out the securing clip at each end of the memory module connector. Figure 84: Installing memory modules (B) Ê Press down on the memory module until the securing clips snap into the cutouts at each end of the module.
Page 192
Main memory Figure 85: Memory dummy module Upgrade and Maintenance Manual CX2550/60/70 M4...
Main memory 7.2.3 Concluding steps Perform the following procedures: "Installing the memory slot air duct (Air cooling only)" on page 64 Ê Ê Identify the correct memory slot according to the mounting order, see section "Memory sequence" on page 185. "Installing the server node in the server enclosure"...
Main memory Removing memory modules Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: tool-less 7.3.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 Ê Locate the desired server node with the ID button. "Shutting down the server node"...
Main memory 7.3.2 Removing a memory module Figure 86: Removing memory modules (A) Ê Eject the desired memory module by pressing out the securing clips at each end of the memory module connector. Figure 87: Removing memory modules (B) Ê Remove the ejected memory module. Upgrade and Maintenance Manual CX2550/60/70 M4...
Main memory 7.3.3 Concluding step Perform the following procedures: "Installing the memory slot air duct (Air cooling only)" on page 64 Ê "Installing the server node in the server enclosure" on page 67 Ê Ê If applicable, reconnect all external cables. "Controls and indicators on the server node"...
Main memory Replacing memory modules Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: tool-less 7.4.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 Ê Locate the desired server node with the ID button. "Shutting down the server node"...
Main memory 7.4.2 Removing a memory module Ê Identify the defective memory slot. Ê Remove the defective memory module, see section "Removing memory modules" on page 194. 7.4.3 Installing a memory module Ê If applicable, prepare the new memory module, see section "Replacing memory modules"...
Main memory Figure 88: Memory cooling pads 7.5.1.1 Adhesive rules for the memory cooling pads Figure 89: Adhesive rules for the memory cooling pads All sides of the memory modules that point to a cooling tube (1) must be covered with a cooling pad (2), see example above.
Page 200
Main memory DIMM 1M DIMM 1F DIMM 1L DIMM 1E DIMM 1K DIMM 1D DIMM 2K DIMM 2D DIMM 2G DIMM 2A DIMM 1G DIMM 1A DIMM 1H DIMM 1B DIMM 1J DIMM 1C Figure 90: DIMM slots overview Number of Number of Memory module Memory module...
Main memory 7.5.2 Replacing memory modules Field Replaceable Unit Hardware: 15 minutes (FRU) Software: 5 minutes Tools: Phillips PH2 / (+) No. 2 screw driver 7.5.2.1 Preliminary steps "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 "Shutting down the server node"...
Page 202
Main memory Figure 92: Cooling pads (processing instructions) Ê Make sure that the edge of the pad is pressed down (1). Pay attention to not attach the cooling pads like this (2). The dummy module is not used in the liquid cooling model. Figure 93: Memory modules (badly prepared) These cases are bad examples of a preparation of the memory modules.
Main memory 7.5.2.3 Concluding steps Before powering on the server node connect the tubes to the tube system of the rack, see the "RackCDU Service Manual". "Installing the server node in the server enclosure" on page 67 Ê Ê If applicable, reconnect all external cables. "Enabling replaced components in the BIOS"...
Page 204
Main memory Upgrade and Maintenance Manual CX2550/60/70 M4...
Processor (CPU) Safety notes CAUTION! Do not install unsupported CPUs. For further information on ● supported CPUs, see section "Basic information" on page 206. Circuit boards and soldered parts of internal options are exposed and ● can be damaged by static electricity. Always discharge static build-up (e.g.
Processor (CPU) Replacing CPU - Air Cooling Field Replaceable Unit Hardware: 15 minutes (FRU) Software: 5 minutes Tools: – Phillips PH2 / (+) No. 2 screw driver CAUTION! CPUs are extremely sensitive to electrostatic discharge and must be handled with care. After a CPU has been removed from its protective sleeve or from its socket, place it upside down on a nonconducting, antistatic surface.
Processor (CPU) 8.2.2 Removing CPU heat sinks 8.2.2.1 Removing the CPU heat sinks Figure 95: Removing the CPU heat sink Ê Loosen the captive screws (circles) following the sequence described below: CAUTION! Please don’t use an electric screwdriver. 1. Loosen the four captive screws one by one (in the sequence 4 to 1) rotating them a half-turn each.
Processor (CPU) CAUTION! Pay special attention not to damage any system board components surrounding the CPU socket. 8.2.3 Removing the CPU type 1 Figure 96: Removing the CPU frame Ê Release the four hooks (see circles). Ê Carefully twist the CPU back and forth to detach the CPU frame from the heat sink (see arrows).
Page 210
Processor (CPU) Figure 97: Removing the CPU Ê Press the two noses in the direction of the arrows (1) and remove the CPU from the CPU frame (2). Ê If the CPU and the heat sink may be reused later, thoroughly clean residual thermal paste from the CPU surface and from the heat sink surface using a lint-free cloth and store the CPU in a save place.
Processor (CPU) 8.2.4 Removing the CPU type 2 Figure 98: Removing the CPU frame Ê Release the four hooks (see circles). Ê Carefully twist the CPU back and forth to detach the CPU frame from the heat sink (see arrows). This may be necessary due to the adhesive quality of the thermal paste located between the heat sink and CPU.
Page 212
Processor (CPU) Figure 99: Removing the CPU Ê Press the three noses in the direction of the arrows (1) and remove the CPU from the CPU frame (2). Ê If the CPU and the heat sink may be reused later, thoroughly clean residual thermal paste from the CPU surface and from the heat sink surface using a lint-free cloth and store the CPU in a save place.
Processor (CPU) 8.2.5 Installing the CPU type 1 Figure 100: Installing the CPU Ê Click the CPU into the CPU frame (see arrows). Make sure that the triangle marks on CPU (A) and on CPU frame (B) are on the same edge. Take care of the nose and the recess on each side (see circles).
Page 214
Processor (CPU) Figure 101: Installing the CPU frame (A) Ê Place the CPU frame onto the heat sink. Make sure that the bottom side of the screw 2 of heat sink (A) and the triangle mark of CPU frame (B) are on the same edge.
Page 215
Processor (CPU) Figure 102: Installing the CPU frame (B) Ê Press down the CPU frame (see arrows). The frame must click into place (see circles). Upgrade and Maintenance Manual CX2550/60/70 M4...
Processor (CPU) 8.2.6 Installing the CPU type 2 Figure 103: Installing the CPU Ê Click the CPU into the CPU frame (see arrows). Make sure that the triangle marks on CPU (A) and on CPU frame (B) are on the same edge. Take care of the nose and the recess on each side (see circles).
Page 217
Processor (CPU) Figure 104: Installing the CPU frame (A) Ê Place the CPU frame onto the heat sink. Make sure that the bottom side of the screw 2 of heat sink (A) and the triangle mark of CPU frame (B) are on the same edge.
Page 218
Processor (CPU) Figure 105: Installing the CPU frame (B) Ê Press down the CPU frame (see arrows). The frame must click into place (see circles). Upgrade and Maintenance Manual CX2550/60/70 M4...
Processor (CPU) 8.2.7 Installing the CPU heat sink 8.2.7.1 CPU heat sink CPU1 Figure 106: CPU heat sink for CPU1 8.2.7.2 CPU heat sink CPU2 Figure 107: CPU heat sink for CPU2 Upgrade and Maintenance Manual CX2550/60/70 M4...
Processor (CPU) 8.2.7.3 Installing the heat sinks Figure 108: CPU heat sink location Empty CPU socket Thick pin Thin pin Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 221
Processor (CPU) Figure 109: Installing the CPU heat sink Ê Carefully seat the heat sink onto the CPU socket. Take care of the pins. There is only one position which fits. Ê Fasten the four captive screws (see circles) in the sequence printed on the heat sink (1 to 4) by hand, by proceeding as follows: Torque: 1.35 Nm (not applicable for Japan) Ê...
Processor (CPU) 8.2.8 Concluding steps Perform the following steps: "Installing the server node in the server enclosure" on page 67 Ê If the Global error LED is flashing with error message "CPU has been changed" on display after the system is powered on, please follow the procedure below.
Processor (CPU) Replacing CPU - Liquid Cooling Field Replaceable Unit Hardware: 15 minutes (FRU) Software: 5 minutes Tools: – Phillips PH2 / (+) No. 2 screw driver CAUTION! CPUs are extremely sensitive to electrostatic discharge and must be handled with care. After a CPU has been removed from its protective sleeve or from its socket, place it upside down on a nonconducting, antistatic surface.
Processor (CPU) "Shutting down the server node" on page 50 Ê Ê If applicable, remove all external cables from the server node. "Removing the server node from the server enclosure" on page 51 Ê 8.3.2 Removing the LC heat sinks Figure 111: Removing the memory modules covers and VRM heat sink covers Ê...
Page 225
Processor (CPU) Figure 113: Disconnecting the LC power cables Ê Disconnect the LC power cables (1), (2). Figure 114: Removing the LC heat sinks (A) Ê Remove the screws from the VRM heat sinks (see circles). CPU 2 CPU 1 Figure 115: Removing the LC heat sinks (B) Upgrade and Maintenance Manual CX2550/60/70 M4...
Processor (CPU) Ê For CPU 1 and CPU 2 LC heat sinks, loosen the captive screws (circles) following the sequence described below: CAUTION! Please don’t use an electric screwdriver. 1. Loosen the four captive screws one by one (in the sequence 4 to 1) rotating them a half-turn each.
Processor (CPU) Ê Remove the metal plate (see cut out). Figure 117: Removing the LC flexible tubes riser Ê Remove the LC flexible tubes riser from the tray. Ê Pull both flexible tubes from the riser. 8.3.2.2 CPU / RAM loop type 1: Removing the flexible tubes (CX2550 M4 / CX2560 M4) Type 2 Figure 118: Loosening the LC bracket Ê...
Page 228
Processor (CPU) Figure 119: Removing the LC flexible tubes Ê Pull both flexible tubes through the holes of the LC bracket (see arrow). Figure 120: Removing the LC flexible tubes riser Ê Remove the LC flexible tubes riser from the tray. Ê...
Processor (CPU) 8.3.2.3 CPU / RAM loop type 1: Removing the flexible tubes (CX2570 M4) Figure 121: Removing the LC bracket Ê Remove the three screws (see circles). Figure 122: Removing the flexible tubes Ê Pull both flexible tubes through the holes of the LC bracket (see arrow). Upgrade and Maintenance Manual CX2550/60/70 M4...
Processor (CPU) 8.3.2.4 Removing the flexible tubes of the CPU/RAM loop type 2 Figure 123: Removing the flexible tubes Ê Remove the two M2 screws (see circles). Ê Remove the LC bracket from the tray (see arrow). 8.3.2.5 Removing the LC heat sinks Ê...
Processor (CPU) 8.3.3 Removing the CPU type 1 Figure 124: Removing the CPU frame Ê Release the four hooks (see circles). Ê Carefully twist the CPU back and forth to detach the CPU frame from the heat sink (see arrows). This may be necessary due to the adhesive quality of the thermal paste located between the heat sink and CPU.
Page 232
Processor (CPU) Figure 125: Removing the CPU Ê Press the two noses in the direction of the arrows (1) and remove the CPU from the CPU frame (2). Ê If the CPU and the heat sink may be reused later, thoroughly clean residual thermal paste from the CPU surface and from the heat sink surface using a lint-free cloth and store the CPU in a save place.
Processor (CPU) 8.3.4 Removing the CPU type 2 Figure 126: Removing the CPU frame Ê Release the four hooks (see circles). Ê Carefully twist the CPU back and forth to detach the CPU frame from the heat sink (see arrows). This may be necessary due to the adhesive quality of the thermal paste located between the heat sink and CPU.
Page 234
Processor (CPU) Figure 127: Removing the CPU Ê Press the three noses in the direction of the arrows (1) and remove the CPU from the CPU frame (2). Ê If the CPU and the heat sink may be reused later, thoroughly clean residual thermal paste from the CPU surface and from the heat sink surface using a lint-free cloth and store the CPU in a save place.
Processor (CPU) 8.3.5 Installing the CPU type 1 Figure 128: Installing the CPU Ê Click the CPU into the CPU frame (see arrows). Make sure that the triangle marks on CPU (A) and on CPU frame (B) are on the same edge. Take care of the nose and the recess on each side (see circles).
Page 236
Processor (CPU) Figure 129: Installing the CPU frame Ê Place the CPU frame onto the heat sink. Make sure that the triangle marks on heat sink (A) and on CPU frame (B) are on the same edge. Ê Press down the CPU frame (see arrows). The frame must click into place (see circles).
Processor (CPU) 8.3.6 Installing the CPU type 2 Figure 130: Installing the CPU Ê Click the CPU into the CPU frame (see arrows). Make sure that the triangle marks on CPU (A) and on CPU frame (B) are on the same edge. Take care of the nose and the recess on each side (see circles).
Page 238
Processor (CPU) Figure 131: Installing the CPU frame Ê Place the CPU frame onto the heat sink. Make sure that the triangle marks on heat sink (A) and on CPU frame (B) are on the same edge. Ê Press down the CPU frame (see arrows). The frame must click into place (see circles).
Processor (CPU) 8.3.7 Installing the LC heat sinks Figure 132: Position of the LC heat sink (CPU 1) Empty CPU socket Thick pin Thin pin How to place thermal sheets: Peel off one side of the protection sheet, when placing a thermal sheet on the system board.
Page 240
Processor (CPU) Figure 133: Thermal sheets overview Thermal sheet (40x7 mm) ① Thermal sheet (44x8.3 mm) ②④ Thermal Sheet (13x7 mm) ③⑤ circle Not used in Japan. Not used in the installation of the LC heat sink (other regions). Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 241
Processor (CPU) Figure 134: Placing thermal sheet 1 Ê Place the thermal sheet (40x7 mm) (1). Figure 135: Placing thermal sheet 2 Ê Place the thermal sheet (44x8.3 mm) on the VR cooling block (2). Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 242
Processor (CPU) Figure 136: Placing thermal sheet 3 Ê Place the thermal sheet (13x7 mm) (3). Figure 137: Placing thermal sheet 4 Ê Place the thermal sheet (44x8.3 mm) on the VR cooling block (4). Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 243
Processor (CPU) Figure 138: Placing thermal sheet 5 Ê Place the thermal sheet (13x7 mm) (5). Figure 139: Aligning the LC kit (A) Ê Hold the LC kit with both hands as shown. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 244
Processor (CPU) Ê Leave the CPU protection caps on. Ê Align LC kit on the CPU socket and the memory sockets. Figure 140: Aligning the LC kit (B) Ê Carefully seat the heat sink onto the CPU socket. Take care of the pins. There is only one position which fits. Figure 141: Routing the SATA cable Ê...
Page 245
Processor (CPU) CPU 2 CPU 1 Figure 142: Installing the LC heat sinks (A) Ê For CPU 1 and CPU 2 LC heat sink, proceed as described below: Ê Carefully seat the heat sink onto the CPU socket. Take care of the pins. There is only one position which fits. Ê...
Page 246
Processor (CPU) Figure 144: Memory module LC heat sink clamps 1 - 6 Clamps for fixing the memory module LC heat sink tubes on the system board. Figure 145: Fastening the memory module LC heat sinks Ê Fix the DIMM module heat sinks with the clamps as shown. Use the clamps according to their numbering, and follow the orientation of the clamps in figure "Memory module LC heat sink clamps"...
Page 247
Processor (CPU) Figure 146: Connecting the LC power cables Power connector for LC pump 1 (CPU1) Power connector for LC pump 2 (CPU2) Ê Run the LC power cables under the tube (see arrow). Ê Connect the LC power cable to the system board. Ê...
Processor (CPU) 8.3.7.1 CPU / RAM loop type 1: Installing the quick connector holder Figure 148: Installing the quick connector holder Attach the top side of the quick connector holder to the CPU cooler as Ê shown. CAUTION! Attach the quick connector holder to the CPU cooler so that the red tube is on the right side when viewed from the front.
Page 249
Processor (CPU) Figure 149: Fixating the quick connector holder Move the quick connector holder to the end of the tube junction. Ê CAUTION! Assemble the quick connector holder so that the recess of the tube junction is at the top. Upgrade and Maintenance Manual CX2550/60/70 M4...
Processor (CPU) 8.3.7.2 CPU / RAM loop type 1: Installing the flexible tubes (CX2550 M4 / CX2560 M4) Type 1 Figure 150: Installing the LC flexible tubes riser Ê Install the LC riser for CX2550 M4 / CX2560 M4 (1). Ê...
Page 251
Processor (CPU) Ensure that the metal plate aligns with left edge of the PCI bracket. Figure 152: Installing the riser module (A) Ê Insert the bolt in the chassis recess (see circle). Upgrade and Maintenance Manual CX2550/60/70 M4...
Processor (CPU) 8.3.7.3 CPU / RAM loop type 1: Installing the flexible tubes (CX2550 M4 / CX2560 M4) Type 2 Figure 153: Installing the LC flexible tubes riser Push both flexible tubes through the holes of the LC bracket (see Ê...
Processor (CPU) Figure 155: Installing the riser module (A) Ê Insert the bolt in the chassis recess (see circle). 8.3.7.4 CPU / RAM loop type 1: Installing the flexible tubes (CX2570 M4) Figure 156: Inserting the flexible tubes Ê Push both flexible tubes through the holes of the LC bracket (1). Ê...
Processor (CPU) Figure 157: Fastening the LC bracket Ê Fasten the LC bracket with three screws (see circles). 8.3.7.5 Installing the flexible tubes of the CPU/RAM loop type 2 Figure 158: Inserting the flexible tubes Ê Install the quick connector of the flexible tubes from the OCP slot area. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 255
Processor (CPU) Figure 159: Fastening the LC bracket Ê Place the LC bracket onto its places (see arrow). Ê Fasten the LC bracket with two M2 screws (see circles). Upgrade and Maintenance Manual CX2550/60/70 M4...
Processor (CPU) 8.3.8 Concluding steps Perform the following steps: "Installing the server node in the server enclosure" on page 67 Ê If the Global error LED is flashing with error message "CPU has been changed" on display after the system is powered on, please follow the procedure below.
Processor (CPU) Replacing the CPU heat sink Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: – Preliminary and concluding steps: tool-less – Removing and installing the CPU heat sink: – Phillips PH2 / (+) No. 2 screw driver 8.4.1 Preliminary steps Before replacing the CPU heat sink, perform the following steps: "Disabling the boot watchdog functionality of ServerView Operations Ê...
Processor (CPU) 8.4.4 Concluding steps Perform the following steps: "Installing the server node in the server enclosure" on page 67 Ê If the Global LED is flashing with error message "CPU has been changed" on display after the system is powered on, please follow the procedure below.
Processor (CPU) Replacing the LC heat sinks Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: – Phillips PH2 / (+) No. 2 screw driver 8.5.1 Preliminary steps Before replacing the CPU heat sink, perform the following steps: "Disabling the boot watchdog functionality of ServerView Operations Ê...
Processor (CPU) 8.5.3 Installing the LC heat sink Figure 160: Installing the thermal sheets on the VRM heat sinks Ê Remove the protective covers from the heat sinks. Ensure not to touch the thermal paste on the bottom of the heat sink. Ê...
Processor (CPU) 8.5.4 Concluding steps Perform the following steps: "Installing the server node in the server enclosure" on page 67 Ê If the Global LED is flashing with error message "CPU has been changed" on display after the system is powered on, please follow the procedure below.
Processor (CPU) Applying thermal paste For Japan, the service engineer must follow the instruction provided separately. If the CPU upgrade or replacement kit contains a new CPU heat sink, a thin layer of thermal compound has already been pre-applied to its lower surface.
Page 263
Processor (CPU) Ê Thoroughly clean residual thermal paste from the CPU surface using a lint- free cloth and store the CPU in a save place. Figure 162: Applying thermal paste (CPU type1) Figure 163: Applying thermal paste (CPU type 2) Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 264
Processor (CPU) Figure 164: Applying thermal paste (SXM2 module) Ê Apply a small streak of thermal paste (see description above) to the center of the CPU surface as shown. CAUTION! Do not mix different types of thermal paste. Upgrade and Maintenance Manual CX2550/60/70 M4...
System board and components This chapter provides information on how to replace the system board module and system board components as its CMOS battery and the M.2 SSD. Safety notes CAUTION! Devices and components inside the server remain hot after ●...
System board and components Safety notes CAUTION! The CMOS battery must be replaced with an identical battery or with ● a battery type recommended by the manufacturer. Keep lithium batteries away from children. ● Do not throw batteries into the trash can. Lithium batteries must be ●...
System board and components 9.1.1.1 Localization of the CMOS battery Figure 165: CMOS battery location Upgrade and Maintenance Manual CX2550/60/70 M4...
System board and components 9.1.2 Removing the CMOS battery Figure 166: Removing the CMOS battery Ê Pull out the depleted CMOS battery of its socket. Upgrade and Maintenance Manual CX2550/60/70 M4...
System board and components 9.1.3 Installing the CMOS battery Figure 167: Installing the CMOS battery Ê Insert the new CMOS battery into its socket as shown. CAUTION! Ensure to insert the CMOS battery with the positive pole (label side) facing to you as shown (see close-up). Upgrade and Maintenance Manual CX2550/60/70 M4...
System board and components 9.1.4 Concluding steps Perform the following procedures: Ê Dispose of the CMOS battery in accordance with local regulations concerning special waste. Ê Install the right riser module, see section "Installing the riser module" on page "Installing the server node in the server enclosure" on page 67 Ê...
System board and components M.2 SSD The server node can be equipped with two M.2 SSDs. 9.2.1 Installing the M.2 SSD Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: Phillips PH1 / (+) No. 1 screw driver 9.2.1.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
System board and components 9.2.1.2 Installing the M.2 SSD Figure 168: M.2 SSD Figure 169: M.2 SSD mounting locations M.2 SSD mounting locations on the system board: M.2 SSD 1 mounting location M.2 SSD 1 mounting location Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 273
System board and components Figure 170: Inserting the M.2 SSD into the slot Ê Insert the M.2 SSD into the slot. Figure 171: Securing the M.2 SSD Ê Secure the M.2 SSD with a screw (see circle). Upgrade and Maintenance Manual CX2550/60/70 M4...
BIOS Setup Utility reference manual. For Japan In order to setup the ESXi, see the corresponding version of the "VMware vSphere Software Description" from the following URL and reinstall ESXi to the M.2 SSD. http://jp.fujitsu.com/platform/server/primergy/software/vmware/manual/ Upgrade and Maintenance Manual CX2550/60/70 M4...
System board and components 9.2.2 Removing the M.2 SSD Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: – Preliminary and concluding steps: tool-less – Main steps: – Phillips PH1 / (+) No. 1 screw driver 9.2.2.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
System board and components 9.2.2.2 Removing the M.2 SSD Figure 172: Removing the M.2 SSD Ê Remove the screw (see circle) and unplug the M.2 SSD (1). 9.2.2.3 Concluding steps Perform the following procedures: Ê Install the left riser module, see section "Installing the riser module"...
Page 277
BIOS Setup Utility reference manual. For Japan In order to setup the ESXi, see the corresponding version of the "VMware vSphere Software Description" from the following URL and reinstall ESXi to the M.2 SSD. http://jp.fujitsu.com/platform/server/primergy/software/vmware/manual/ Upgrade and Maintenance Manual CX2550/60/70 M4...
System board and components 9.2.3 Replacing the M.2 SSD Upgrade and Repair Unit Hardware: 5 minutes (URU) Software: 10 minutes Tools: – Preliminary and concluding steps: – combination pliers and flat nose pliers – Main steps: – Phillips PH1 / (+) No. 1 screw driver 9.2.3.1 Preliminary steps Perform the following procedures:...
System board and components 9.2.3.3 Re-installing the M.2 SSD Ê Install the M.2 SSD, see "Installing the M.2 SSD" on page 272. 9.2.3.4 Concluding steps Perform the following procedures: Ê Install the left riser module, see section "Installing the riser module" on page "Installing the server node in the server enclosure"...
Page 280
System board and components In order to setup the ESXi, see the corresponding version of the "VMware vSphere Software Description" from the following URL and reinstall ESXi to the M.2 SSD. http://jp.fujitsu.com/platform/server/primergy/software/vmware/manual/ Upgrade and Maintenance Manual CX2550/60/70 M4...
System board and components Trusted Platform Module (TPM) (no information available) 9.3.1 Installing the TPM Field Replaceable Unit Hardware: 5 minutes (FRU) Software: 5 minutes Tools: – Bit screw driver – TPM bit insert For Japan: – TPM module fixing tool (S26361-F3552-L909) Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
System board and components 9.3.1.1 Installing the TPM Figure 173: TPM installation kit - example 1 Figure 174: TPM installation kit - example 2 TPM (Trusted Platform Module) Special screw for TPM TPM spacer TPM bit insert for TPM special screw The black TPM spacer is not used in this server.
Page 283
System board and components Figure 175: Position on the system board Figure 176: Inserting the TPM spacer on the system board Ê Insert the TPM spacer into the hole on the system board. Figure 177: TPM bit insert Upgrade and Maintenance Manual CX2550/60/70 M4...
System board and components Ê Attach the TPM bit insert or TPM module fixing tool (for Japan) to a bit screw driver. Figure 178: Installing the TPM Ê Connect the TPM to the system board (1). Ê Fasten the TPM with the special screw for the TPM using the TPM bit insert or TPM module fixing tool (for Japan) (2).
System board and components Ê Reconnect all cables to the system board. For a complete cabling overview, see section "Cabling overview" on page 420. "Resuming BitLocker functionality" on page 96 Ê Ê Enable TPM in the system board BIOS. Proceed as follows: Ê...
For further information on how to disable BitLocker drive encryption, see the Microsoft Knowledge Base. Fujitsu service partners will find additional information (also available in Japanese) on the Fujitsu Extranet web pages. Ê Disable TPM in the system board BIOS. Proceed as follows: Ê...
System board and components For detailed information on how to access the BIOS and modify settings, see the corresponding BIOS Setup Utility reference manual. "Suspending BitLocker functionality" on page 71 Ê "Shutting down the server node" on page 50 Ê Ê...
Page 288
System board and components Slowly and carefully increase the pressure on the screw until it begins to turn. The effort when loosing the screw should be as low as possible. Otherwise the thin metal bar may break, rendering it impossible to loosen the screw.
TPM later. The spare parts act as TPM2.0. For the use as TPM1.2, the customer need to update the firmware to TPM1.2 after replacement. For firmware, please see below. http://ts.fujitsu.com/support/ http://www.fujitsu.com/jp/products/computing/servers/primergy/downloads/ (for Japan) Upgrade and Maintenance Manual...
System board and components 9.3.3.1 Preliminary steps "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 "Suspending BitLocker functionality" on page 71 Ê Ê Locate the desired server with the ID button. "Shutting down the server node" on page 50 Ê...
System board and components iRMC microSD card The iRMC microSD card is necessary for using the embedded Lifecycle Management (eLCM) functionality of the iRMC. It requires a valid eLCM license key, which is always purchased together with the iRMC microSD card and activated through the iRMC webinterface.
System board and components 9.4.1.2 Installing the iRMC microSD card Figure 181: iRMC microSD mounting place Figure 182: iRMC microSD card Figure 183: Installing the iRMC microSD card Ê With the label facing up, insert the iRMC microSD card into the microSD card slot (1) as far as it will go (2).
System board and components 9.4.1.3 Concluding steps "Installing the riser module" on page 55 Ê "Installing the server node in the server enclosure" on page 67 Ê "Enabling SVOM boot watchdog functionality" on page 88 Ê Upgrade and Maintenance Manual CX2550/60/70 M4...
System board and components 9.4.2 Removing the iRMC microSD card Upgrade and Repair Unit Average task duration: (URU) 5 minutes Tools: tool-less 9.4.2.1 Preliminary steps "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 "Shutting down the server node" on page 50 Ê...
System board and components Destroying the defective iRMC microSD card CAUTION! The iRMC microSD card contains customer information. After replacing the iRMC microSD card, hand the defective card over to the customer. If the customer requests disposal of the defective iRMC microSD card, proceed as follows: Ê...
System board and components 9.4.3 Replacing the iRMC microSD card Upgrade and Repair Unit Average task duration: (URU) 5 minutes Tools: tool-less 9.4.3.1 Preliminary steps "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 "Shutting down the server node" on page 50 Ê...
System board and components Dual microSD 64GB Enterprise 9.5.1 Installing the Dual microSD 64GB Enterprise Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: tool-less 9.5.1.1 Preliminary steps "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 Ê...
Page 298
System board and components Figure 186: Position on the system board Figure 187: Connecting the cable to the Dual microSD 64GB Enterprise Ê Connect the cable to the Dual microSD 64GB Enterprise. Upgrade and Maintenance Manual CX2550/60/70 M4...
System board and components Figure 188: Installing the Dual microSD 64GB Enterprise Ê Insert the Dual microSD 64GB Enterprise into the connector "RAID ON CHIP" on the system board (1). Ê Connect the cable to the connector "ROC" on the system board (2). For the cable plan see chapter "Appendix B"...
System board and components 9.5.2 Removing the Dual microSD 64GB Enterprise Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: tool-less 9.5.2.1 Preliminary steps "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 Ê Locate the desired server with the ID button. "Shutting down the server node"...
System board and components 9.5.2.3 Concluding steps Ê Install the left riser module, see section "Installing the riser module" on page "Installing the server node in the server enclosure" on page 67 Ê Ê If applicable, reconnect all external cables. "Controls and indicators on the server node"...
System board and components Figure 190: Removing the microSD card Ê To eject the microSD card, gently push it in and then let go (1). Ê Pull the microSD card straight out of its slot (2). Ê Install both microSD cards on the new Dual microSD 64GB Enterprise. Proceed as described in the following: Figure 191: Installing the microSD card Ê...
System board and components 9.5.4 Replacing the microSD card Upgrade and Repair Unit Hardware: 5 minutes (URU) Tools: a pair of side-cutting pliers 9.5.4.1 Preliminary steps "Locating the defective server" on page 45 Ê "Shutting down the server node" on page 50 Ê...
System board and components Ê Install the Dual microSD 64GB Enterprise, see section "Installing the Dual microSD 64GB Enterprise" on page 297. 9.5.4.3 Concluding steps "Installing the memory slot air duct (Air cooling only)" on page 64 Ê Ê If applicable, reconnect all external cables. "Installing the server node in the server enclosure"...
System board and components Replacing the system board Field Replaceable Unit Hardware: 50 minutes (FRU) Software: 10 minutes Tools: – tool-less – Removing and installing the CPU heat sink: – Phillips PH2 / (+) No. 2 screw driver – Removing and installing the M.2 SSD (if applicable): –...
Page 306
System board and components Note on system information backup / restore To avoid the loss of BIOS/iRMC settings values, such as the model name, device information on the serial number etc. when replacing the system board, a backup copy of important system configuration data is automatically stored from the system board NVRAM to the Chassis interface board of midplane kit.
System board and components 9.6.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 Ê Locate the desired server with the ID button. "Shutting down the server node" on page 50 Ê...
System board and components 9.6.2.1 Preliminary works: server node with Liquid Cooling Figure 192: VR cooling blocks and spacers Before removing the system board you must remove the VR cooling blocks (see frames) and spacers (see circles). This procedure is not applied for Japan. Figure 193: Removing ten screws from the tray underside Ê...
System board and components Ê Remove 10 screws (see red circles). Use a hexagonal nut screw driver to secure the spacers while removing the corresponding screws from the bottom of the tray. Figure 194: Removing VR cooling blocks and spacers Ê...
Page 310
System board and components Ê Carefully shift the system board in the direction of the arrow until the plug shells disengage from the cut-outs in the I/O panel (see blue circles). Ê Hold the defective system board by the memory module ejectors and lift it in a vertical motion out of the chassis.
System board and components 9.6.2.3 Installing the system board Figure 196: Installing the system board Ê Hold the new system board by the memory module ejectors. CAUTION! – Do not lift or handle the system board by any of its heat sinks! –...
Page 312
System board and components CAUTION! Check that the power button has a click feeling when it is pushed. Figure 197: Replacing the system board – Verify that there is no space (see blue circle). Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 313
System board and components This is the good case. This is the bad case. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 314
System board and components In case of Liquid Cooling, the VRM heat sinks need to be replaced after replacing the system board. (This procedure is not applied for Japan.) Ê Lay the tray on a soft, antistatic surface with its component side facing down. Figure 198: Removing ten screws from the tray underside Ê...
Page 315
System board and components Figure 199: Thermal sheets overview Thermal sheet (26x7 mm) Thermal sheet(17x7 mm) squares Not used in this procedure. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 316
System board and components Figure 200: Placing the VR cooling block thermal sheets Ê Place the thermal sheets (1)(2) on the connection surfaces of the VR cooling blocks. Figure 201: Installing the VR cooling blocks Ê Replace the VRM air cooling heat sinks for the VR cooling blocks. Ê...
System board and components Ê Fix the stand-off for VR cooling blocks with 4 M2 screws from the back side of the tray (2). Use a hexagonal nut screw driver to secure the stud while fastening the screw from the bottom of the tray. Ê...
System board and components "Installing the iRMC microSD card" on page 292 (if applicable) Ê Ê Reconnect all cables to the system board. For a complete cabling overview, see section "Cabling overview" on page 420. "Installing OCP mezzanine cards" on page 159 (if applicable) Ê...
Page 319
System board and components Ê After replacing the system board in a server running Linux OS, update the MAC address of the onboard network controller in the related NIC definition file, see section "Updating the NIC configuration file in a Linux and VMware environment"...
Page 320
System board and components Upgrade and Maintenance Manual CX2550/60/70 M4...
GPGPU extension tray Safety notes CAUTION! Do not damage or modify internal cables or devices. Doing so may ● cause a device failure, fire, or electric shock. Devices and components inside the server node remain hot after ● shutdown. After shutting down the server, wait for hot components to cool down before installing or removing internal options.
GPGPU extension tray 10.1 Basic information With the GPGPU extension tray, the system offers two slots for GPGPUs Spacer GPGPU 1 GPGPU 2 Spacer Figure 202: GPGPU extension tray overview GPGPU riser (R) for GPGPU 1 connected to CPU1 GPGPU riser (L) for GPGPU 2. There are two riser (L) variants, see figure "GPGPU riser cards"...
GPGPU extension tray For more information, see "CX2570 M4 PCIe Slot / OCP slot population order (air cooling)" on page 113. 10.2 Installing GPGPU extension in slot GPGPU 1 Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: tool-less Main steps: PH2 / (+) No.
GPGPU extension tray 10.2.2 Installing the GPGPU Figure 204: GPGPU 1 mounting location PCI riser (R), connected to CPU1 Figure 205: Connecting the short power cable to the GPGPU Ê Connect the short power cable to the GPGPU. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 325
GPGPU extension tray Figure 206: Connecting the GPGPU to PCIe riser (R) Ê Connect the GPGPU to the riser (R). Figure 207: Installing the PIB Ê At a slight angle, lower the PIB into the chassis. Ê Carefully shift the PIB in the direction of the arrow until the plug shell engage with the cut-out in the chassis.
Page 326
GPGPU extension tray Figure 208: Connecting the GPGPU power cable Ê Connect the GPGPU power cable, see circle. Figure 209: Installing the spacer Ê Insert the spacer as shown, so that the hooks engage in the recesses (see circles). Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 327
GPGPU extension tray Figure 210: I2C cable routing Ê Route the I2C cable as shown. Caution Ê Route the power cable so that the power cable is inside the rear side edge of the GPGPU tray. Ê Route the power cable so that the power cable is lower than the top of the GPGPU tray.
GPGPU extension tray 10.2.3 Concluding steps Perform the following procedures: "Installing the server node in the server enclosure" on page 67 Ê Ê If applicable, connect all external cables to the server node. "Updating or recovering the system board BIOS and iRMC" on page 77 Ê...
GPGPU extension tray 10.3.2 Removing the GPGPU Figure 211: Removing the spacer Ê Remove the spacer from the tray. Figure 212: Disconnecting the GPGPU power cable and the I2C cable from the PIB Ê Disconnect the GPGPU power cable and the I2C cable from the PIB, see circles.
Page 330
GPGPU extension tray Figure 213: Removing the PIB Loosen the captive screw (see circle). Ê Ê Carefully shift the PIB in the direction of the arrow until the plug shell disengage from the cut-out in the chassis. Ê Lift the PIB out of the chassis. Figure 214: Removing the GPGPU from the chassis Upgrade and Maintenance Manual CX2550/60/70 M4...
GPGPU extension tray Ê Disconnect the GPGPU from the riser card (see arrow). Ê Lift the GPGPU in a vertical motion out of the chassis. Figure 215: Disconnecting the short power cable from the GPGPU Ê Disconnect the short power cable from the GPGPU. 10.3.3 Concluding steps Perform the following procedures: "Installing the server node in the server enclosure"...
GPGPU extension tray 10.4 Replacing the GPGPU in slot GPGPU 1 Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: tool-less Main steps: PH2 / (+) No. 2 screw 10.4.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
GPGPU extension tray 10.4.3 Installing the GPGPU Figure 216: Removing the bracket from the GPGPU Ê If present, remove the bracket of the new GPGPU by removing three screws (see circles) There might also be a screw on the bottom side of GPGPU (see dotted circle).
GPGPU extension tray 10.4.4 Concluding steps Perform the following procedures: "Installing the server node in the server enclosure" on page 67 Ê Ê If applicable, connect all external cables to the server node. "Updating or recovering the system board BIOS and iRMC" on page 77 Ê...
GPGPU extension tray 10.5.2 Installing the GPGPU Figure 217: GPGPU 2 mounting location PCI riser (L)-P1, connected to CPU1 For information about PCI riser (L) variants see figure "GPGPU riser cards" on page 322. Figure 218: Connecting the long GPGPU power cable Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 336
GPGPU extension tray Ê Connect the long power cable to the GPGPU (see circle). Figure 219: Connecting the GPGPU to PCIe riser (R) Ê Connect the GPGPU to the riser (R). Figure 220: Connecting the GPGPU power cable to the PIB Ê...
GPGPU extension tray Figure 221: Installing the spacer Ê Insert the spacer as shown, so that the hooks engage in the recesses (see circles). 10.5.3 Concluding steps Perform the following procedures: "Installing the server node in the server enclosure" on page 67 Ê...
GPGPU extension tray 10.6 Removing the GPGPU extension from slot GPGPU 2 Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: tool-less Main steps: PH2 / (+) No. 2 screw 10.6.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
GPGPU extension tray 10.6.2 Removing the GPGPU Figure 222: Removing the spacer Ê Remove the spacer from the tray. Figure 223: Disconnecting the GPGPU power cable from the PIB Ê Disconnect the power cable (see circle) from the PIB. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 340
GPGPU extension tray Figure 224: Removing the GPGPU from the riser (L) Ê Disconnect the GPGPU from the riser card (L), see arrow. Ê Lift the GPGPU in a vertical motion out of the chassis. Figure 225: Disconnecting the long GPGPU power cable Ê...
GPGPU extension tray 10.6.3 Concluding steps Perform the following procedures: "Installing the server node in the server enclosure" on page 67 Ê Ê If applicable, connect all external cables to the server node. "Updating or recovering the system board BIOS and iRMC" on page 77 Ê...
GPGPU extension tray 10.7 Replacing the GPGPU in slot GPGPU 2 Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: tool-less Main steps: PH2 / (+) No. 2 screw 10.7.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
GPGPU extension tray 10.7.3 Installing the GPGPU Figure 226: Removing the bracket from the GPGPU Ê If present, remove the bracket of the new GPGPU by removing three screws (see circles) There might also be a screw on the bottom side of GPGPU (see dotted circle).
GPGPU extension tray 10.7.4 Concluding steps Perform the following procedures: "Installing the server node in the server enclosure" on page 67 Ê Ê If applicable, connect all external cables to the server node. "Updating or recovering the system board BIOS and iRMC" on page 77 Ê...
GPGPU extension tray 10.8 Power cables Figure 227: GPGPU power cables GPGPU power cable (8 pins) GPGPU power cable (6 pins) There are 4 kinds of power cables to support different GPGPU types and mounting locations. – 1. Long 8pin –...
GPGPU extension tray 10.9 Replacing the GPGPU Riser (R) 10.9.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 Ê Locate the desired server node with the ID button. "Shutting down the server node" on page 50 Ê...
GPGPU extension tray Ê Place the GPGPU tray so that the system board connector of the riser (see oval) is not damaged. Ê Disconnect the I2C cable from the riser (see arrow). Ê Remove four screws from the outside of the chassis in the order of numbering (1 - 4).
Page 348
GPGPU extension tray "Installing GPGPU extension in slot GPGPU 1" on page 323 (if applicable) Ê "Installing GPGPU extension in slot GPGPU 2" on page 334 (if applicable) Ê "Installing the GPGPU / SXM2 extension tray" on page 65 (if applicable) Ê...
GPGPU extension tray 10.10 Replacing the GPGPU riser (L) This section describes how to replace the GPGPU riser (L)-P1. The GPGPU riser (L)-P2 is replaced in the same way. For information about PCI riser (L) variants see figure "GPGPU riser cards"...
GPGPU extension tray 10.10.2 Removing the GPGPU riser Figure 230: Removing the riser (L)-P1 Ê Place the GPGPU tray so that the system board connector of the riser (see oval) is not damaged. Ê Remove three screws from the outside of the chassis. Ê...
GPGPU extension tray 10.10.3 Installing the GPGPU riser Figure 231: Installing the riser (L)-P1 Ê Insert the riser in a vertical motion in the chassis. CAUTION Ensure that the system board connector of the riser (see oval) is not damaged. Ê...
GPGPU extension tray 10.11 Replacing the Power Interface Board (PIB) 10.11.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê Manager" on page 73 Ê Locate the desired server node with the ID button. "Shutting down the server node"...
Page 353
GPGPU extension tray Figure 233: Removing the PIB Loosen the captive screw (see circle). Ê Ê Carefully shift the PIB in the direction of the arrow until the plug shell disengage from the cut-out in the chassis. Ê Lift the PIB out of the chassis. Upgrade and Maintenance Manual CX2550/60/70 M4...
GPGPU extension tray 10.11.3 Installing the PIB Figure 234: Installing the PIB Ê At a slight angle, lower the PIB into the chassis. Ê Carefully shift the PIB in the direction of the arrow until the plug shell engage with the cut-out in the chassis. Fasten the PIB with the captive screw (see circle).
GPGPU extension tray Figure 235: Disconnecting power cables and I2C cable from the PIB Ê Connect the power cables of GPGPU 1 (1), GPGPU 2 (2) and the I2C cable (3) to the PIB. 10.11.4 Concluding steps Perform the following procedures: "Installing the server node in the server enclosure"...
SXM2 extension tray Safety notes CAUTION! Do not damage or modify internal cables or devices. Doing so may ● cause a device failure, fire, or electric shock. Devices and components inside the server node remain hot after ● shutdown. After shutting down the server, wait for hot components to cool down before installing or removing internal options.
SXM2 extension tray 11.1 Basic information With the SXM2 extension tray, the system offers four slots for SXM2 modules. Overview Figure 236: SXM2 extension tray overview (not populated) PCIe switch SXM2 slot 1 SXM2 slot 2 SXM2 slot 3 SXM2 slot 4 Connector for riser (R) at the bottom of the baseboard (not visible) Connector for riser (L) at the bottom of the baseboard (not visible) For more information, see...
Page 359
SXM2 extension tray SXM2 riser cards Figure 237: SXM2 riser cards SXM2 riser card (L) type 1, connected to CPU1 and CPU2 SXM2 riser card (L) type 2, connected to CPU1 and CPU2, PCIe slot x16 SXM2 riser card (R), connected to CPU1 Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 360
SXM2 extension tray SXM2 module Figure 238: SXM2 module SXM2 Liquid cooling (LC) kit Figure 239: SXM2 LC kit 1 LC heat sink for SXM2 module 1 2 LC heat sink for SXM2 module 2 3 LC heat sink for SXM2 module 3 4 LC heat sink for SXM2 module 4 A Thermal sheet B Tube fixation bracket and M3 flat screw...
SXM2 extension tray 11.2 Replacing SXM2 modules Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: tool-less Main steps: PH2 / (+) No. 2 screw 11.2.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
Page 362
SXM2 extension tray Ê Remove the screw (A) and remove the flexible tube fixation bracket. Figure 241: Loosening the tube guides from the LC bracket Ê Remove three screws (see circles). Figure 242: Removing the LC heat sink from the PCIe switch Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 363
SXM2 extension tray Ê Loosen the captive screws (see circles) following the sequence described below and using a #2 screwdriver: CAUTION Please don’t use an electric screwdriver. 1. Loosen the captive screws one by one rotating them a half-turn each. 2.
Page 364
SXM2 extension tray Figure 244: Removing LC heat sinks from SXM2 modules 3 (A) and 4 (B) Ê Loosen the captive screws of SXM2 module 4 (B) (see circles) following the sequence described below and using a #2 screwdriver: CAUTION Please don’t use an electric screwdriver.
Page 365
SXM2 extension tray Type 2 Figure 245: Removing the flexible tube fixation bracket Ê Remove the screw (A) and remove the flexible tube fixation bracket. Figure 246: Loosening and lifting up the LC bracket Ê Loosen the two screws (see circles) of the LC bracket and lift up the LC bracket with tubes (see arrow).
Page 366
SXM2 extension tray Figure 247: Loosening the LC bracket Ê Loosen the three screws (see circles) of the LC bracket. Figure 248: Removing the flexible tubes Ê Pull both flexible tubes through the holes of the LC bracket (see arrow). Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 367
SXM2 extension tray Figure 249: Removing the LC heat sink from the PCIe switch Ê Loosen the captive screws (see circles) following the sequence described below and using a #2 screwdriver: CAUTION Please don’t use an electric screwdriver. 1. Loosen the captive screws one by one rotating them a half-turn each. 2.
Page 368
SXM2 extension tray Figure 250: Removing LC heat sinks from SXM2 modules 3 (A) and 4 (B) Ê Loosen the captive screws of SXM2 module 4 (B) (see circles) following the sequence described below and using a #2 screwdriver: CAUTION Please don’t use an electric screwdriver.
SXM2 extension tray 11.2.2.2 Removing liquid cooling from SXM2 modules 1 and 2 Type 1 CAUTION Perform the following procedures: "Removing liquid cooling from SXM2 modules 3 and 4" on page 361 Figure 251: Loosening the tube guides from the LC bracket Ê...
Page 370
SXM2 extension tray Figure 253: Removing the LC heat sink from the PCIe switch 1 Ê Disconnect the LC power cables form the base board (see oval). Ê Loosen the captive screws (see circles) following the sequence described below and using a #2 screwdriver: CAUTION Please don’t use an electric screwdriver.
Page 371
SXM2 extension tray Figure 254: Removing the PLX bracket Ê Remove the PLX bracket (see arrow), if it is present. If the PLX bracket is not attached, continue with the next step. Figure 255: Removing LC heat sinks from SXM2 modules 1 (A) and 2 (B) Ê...
Page 372
SXM2 extension tray 1. Loosen the four captive screws one by one (in the sequence 4 to 1) rotating them a half-turn each. 2. Loosen the captive screws 4 and 3 rotating them two or three turns each. 3. Repeat the step 2 until the screws 4 and 3 are completely loosened. 4.
Page 373
SXM2 extension tray Type 2 CAUTION Perform the following procedures: "Removing liquid cooling from SXM2 modules 3 and 4" on page 361 Figure 256: Loosening and lifting up the LC bracket Ê Loosen the two screws (see circles) of the LC bracket and lift up the LC bracket with tubes (see arrow).
Page 374
SXM2 extension tray Ê Loosen the three screws (see circles) of the LC bracket. Figure 258: Removing the flexible tubes Ê Pull both flexible tubes through the holes of the LC bracket (see arrow). Figure 259: Removing the LC heat sink from the PCIe switch 1 Ê...
Page 375
SXM2 extension tray CAUTION Please don’t use an electric screwdriver. 1. Loosen the captive screws one by one rotating them a half-turn each. 2. Loosen the captive screws rotating them two or three turns each. 3. Repeat the step 2 until the screws are completely loosened. Figure 260: Removing the PLX bracket Ê...
Page 376
SXM2 extension tray Figure 261: Removing LC heat sinks from SXM2 modules 1 (A) and 2 (B) Ê Loosen the captive screws of SXM2 module 1 (A) (see circles) following the sequence described below and using a #2 screwdriver: CAUTION Please don’t use an electric screwdriver.
SXM2 extension tray 11.2.3 Removing the SXM2 module Ê Loosen the eight captive screws on the SXM2 module by the sequence from 8 to 1 Ê Carefully remove the defective SXM2 module from its sockets in a vertical motion. Upgrade and Maintenance Manual CX2550/60/70 M4...
SXM2 extension tray 11.2.4 Installing the SXM2 module Ê Carefully seat the SXM2 module on the eight threaded holes as shown. Ê Tighten the eight captive screws by the sequence from 1 to 8 Ê Apply thermal paste to the CPU surface, see section "Applying thermal paste"...
SXM2 extension tray 11.2.5 Installing liquid cooling (LC) 11.2.5.1 Preparing the SXM2 modules for LC Figure 262: Sticking the thermal sheets on the VRMs Ê Stick the thermal sheets on the VRMs. Make sure that the thermal sheets are centered on the VRMs. 11.2.5.2 Installing liquid cooling for SXM2 modules 1 and 2 Type 1 Figure 263: Installing LC heat sinks to SXM2 modules 1 (A) and 2 (B)
Page 380
SXM2 extension tray Ê For SXM2 module 1 (A), fasten the four captive screws (see circles) in the sequence of the numbering (1 to 4) by proceeding as follows: Ê At first, fasten the four captive screws one by one (1 to 4) by hand rotating them three turns.
Page 381
SXM2 extension tray Figure 265: Rotating the PLX bracket Rotate the PLX bracket 90 degrees if it doesn’t fit on the chip (see arrows). Figure 266: Installing the LC heat sink for PCIe switch 1 Ê Carefully seat the heat sink onto the PCIe switch 1. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 382
SXM2 extension tray Ê Fasten the two captive screws (see circles) as follows: Ê At first, fasten the two captive screws one by one by hand rotating them three turns. Ê Then, fasten the two captive screws one by one by hand until the screws are completely tightened.
Page 383
SXM2 extension tray Figure 268: Fixating the quick connector holder Move the quick connector holder to the end of the tube junction. Ê CAUTION! Assemble the quick connector holder so that the recess of the tube junction is at the top. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 384
SXM2 extension tray Figure 269: Laying the LC tubes Ê Lay the flexible tubes as shown and push the ends of the tubes through the holes of the LC bracket (see arrows). 1 SXM2 module 1 tube 2 SXM2 module 2 tube CAUTION Route the SXM1 tube under the SXM2 tube.
Page 385
SXM2 extension tray Figure 271: Fastening the tube guides to the LC bracket Ê Fasten the tube guides to the LC bracket with three screws (see circles). Type 2 Figure 272: Installing LC heat sinks to SXM2 modules 1 (A) and 2 (B) Ê...
Page 386
SXM2 extension tray Ê Repeat this procedure for SXM2 module 2 (B). Figure 273: Installing the PLX bracket Ê If the PLX bracket is present, install the PLX bracket on the PCIe switch 1 (see arrow). Figure 274: Rotating the PLX bracket Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 387
SXM2 extension tray Rotate the PLX bracket 90 degrees if it doesn’t fit on the chip (see arrows). Figure 275: Installing the LC heat sink for PCIe switch 1 Ê Carefully seat the heat sink onto the PCIe switch 1. Ê...
Page 388
SXM2 extension tray Figure 276: Installing the quick connector holder Attach the quick connector holder to the CPU cooler from below as Ê shown. CAUTION! Attach the quick connector holder to the CPU cooler so that the red tube is on the right side when viewed from the front. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 389
SXM2 extension tray Figure 277: Fixating the quick connector holder Move the quick connector holder to the end of the tube junction. Ê CAUTION! Assemble the quick connector holder so that the recess of the tube junction is at the top. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 390
SXM2 extension tray Figure 278: Laying the LC tubes CAUTION Route the SXM1 tube under the SXM2 tube. Ê Lay the flexible tubes as shown and push the ends of the tubes through the holes of the LC bracket (see arrows). 1 SXM2 module 1 tube 2 SXM2 module 2 tube Upgrade and Maintenance Manual...
Page 391
SXM2 extension tray Figure 279: Installing the flexible tubes Push both flexible tubes through the holes of the LC bracket (see Ê arrow). Figure 280: Fastening the LC bracket Fasten the LC bracket with three screws (see circles). Ê Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 392
SXM2 extension tray Figure 281: Installing the LC bracket Put the LC bracket with tubes (see arrow) and fasten the LC bracket Ê with two screws (see circles). Upgrade and Maintenance Manual CX2550/60/70 M4...
SXM2 extension tray 11.2.5.3 Installing liquid cooling for SXM2 modules 3 and 4 Type 1 Figure 282: Installing LC heat sinks to SXM2 modules 3 (A) and 4 (B) Ê Carefully seat the heat sink onto the SXM2 sockets. Ê For SXM2 module 3 (A), fasten the four captive screws (see circles) in the sequence of the numbering (1 to 4) by proceeding as follows: Ê...
Page 394
SXM2 extension tray Figure 283: Installing the quick connector holder Attach the quick connector holder to the CPU cooler from below as Ê shown. CAUTION! Attach the quick connector holder to the CPU cooler so that the red tube is on the right side when viewed from the front. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 395
SXM2 extension tray Figure 284: Fixating the quick connector holder Move the quick connector holder to the end of the tube junction. Ê CAUTION! Assemble the quick connector holder so that the recess of the tube junction is at the top. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 396
SXM2 extension tray Figure 285: Laying the LC tubes Ê Pull the flexible tubes out of the LC bracket (see arrow). Ê Lay the flexible tubes as shown and push the ends of the tubes through the holes of the LC bracket (see arrows). Ê...
Page 397
SXM2 extension tray Figure 286: Installing the LC heat sink for PCIe switch 2. Ê Carefully seat the heat sink onto the PCIe switch 2. Ê Fasten the two captive screws (see circles) as follows: Ê At first, fasten the two captive screws one by one by hand rotating them three turns.
Page 398
SXM2 extension tray Figure 287: Fastening the tube guides to the LC bracket Ê Fasten the tube guides to the LC bracket with three screws (see circles). Figure 288: Installing the tube fixation bracket Ê Place the tube fixation bracket as shown and fasten it with one M3 screw (A). Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 399
SXM2 extension tray Type 2 Figure 289: Installing LC heat sinks to SXM2 modules 3 (A) and 4 (B) Ê Carefully seat the heat sink onto the SXM2 sockets. Ê For SXM2 module 3 (A), fasten the four captive screws (see circles) in the sequence of the numbering (1 to 4) by proceeding as follows: Ê...
Page 400
SXM2 extension tray Figure 290: Installing the LC heat sink for PCIe switch 2 Ê Carefully seat the heat sink onto the PCIe switch 2. Ê Fasten the two captive screws (see circles) as follows: Ê At first, fasten the two captive screws one by one by hand rotating them three turns.
Page 401
SXM2 extension tray Figure 291: Installing the quick connector holder Attach the quick connector holder to the CPU cooler from below as Ê shown. CAUTION! Attach the quick connector holder to the CPU cooler so that the red tube is on the right side when viewed from the front. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 402
SXM2 extension tray Figure 292: Fixating the quick connector holder Move the quick connector holder to the end of the tube junction. Ê CAUTION! Assemble the quick connector holder so that the recess of the tube junction is at the top. Figure 293: Installing the flexible tubes Push both flexible tubes through the holes of the LC bracket (see Ê...
Page 403
SXM2 extension tray Figure 294: Fastening the LC bracket Fasten the LC bracket with three screws (see circles). Ê Figure 295: Installing the LC bracket Put the LC bracket with tubes (see arrow) and fasten the LC bracket Ê with two screws (see circles). Upgrade and Maintenance Manual CX2550/60/70 M4...
SXM2 extension tray Figure 296: Installing the tube fixation bracket Ê Place the tube fixation bracket as shown and fasten it with one M3 screw (A). 11.2.6 Concluding steps Perform the following procedures: "Installing the server node in the server enclosure" on page 67 Ê...
SXM2 extension tray 11.3 Replacing the SXM2 LC Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: tool-less Main steps: PH2 / (+) No. 2 screw 11.3.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
Page 406
SXM2 extension tray "Updating or recovering the system board BIOS and iRMC" on page 77 Ê applicable) "Controls and indicators on the server node" on page 448 Ê "Enabling SVOM boot watchdog functionality" on page 88 Ê Upgrade and Maintenance Manual CX2550/60/70 M4...
SXM2 extension tray Ê Place the SXM2 tray on the left side so that the system board connectors of the risers are not damaged. Ê Remove two screws (see circles). Ê Unplug the riser from the SXM2 base board. 11.4.3 Installing the SXM2 riser (R) Figure 298: Installing the riser (R) Ê...
SXM2 extension tray 11.5 Replacing the SMX2 Riser (L) type 1 Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: tool-less Main steps: PH2 / (+) No. 2 screw 11.5.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
SXM2 extension tray Ê Remove two screws (see circles). Ê Unplug the riser from the SXM2 base board. 11.5.3 Installing the SXM2 riser (L) type 1 Figure 300: Installing the riser (L) type 1 Ê Place the SXM2 tray on the right side so that the system board connector of the riser are not damaged.
SXM2 extension tray 11.6 Replacing the SMX2 Riser (L) type 2 Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: tool-less Main steps: PH2 / (+) No. 2 screw 11.6.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
SXM2 extension tray Ê Hold the edge of the SXM2 riser card (L) type 2 and lift it up straight on and remove it from the slot. Ê If applicable, replace the expansion card from the failed riser card to the new one, see section "Expansion cards in the SXM2 riser card (L) type 2"...
SXM2 extension tray Figure 303: Installing the riser (L) type 2 Ê Lower the SXM2 riser card (L) type 2 straight on and plug it in the slot. 11.6.4 Concluding steps Perform the following procedures: "Installing the GPGPU / SXM2 extension tray" on page 65 Ê...
SXM2 extension tray 11.7 Replacing the SMX2 base board Field Replaceable Unit Hardware: 45 minutes (FRU) Tools: Preliminary and main steps: PH2 / (+) No. 2 screw 11.7.1 Preliminary steps Perform the following procedures: "Disabling the boot watchdog functionality of ServerView Operations Ê...
SXM2 extension tray 11.7.2 Removing the SXM2 base board Figure 304: Removing the SXM2 base board (A) Ê Remove 7 screws from the SXM2 base board (see circles). Ê Carefully shift the SXM2 base board in the direction of the arrow until the plug shells disengage from the cut-outs in the I/O panel.
SXM2 extension tray 11.7.3 Installing the SXM2 base board Figure 306: Installing the SXM2 base board (A) Ê At a slight angle, lower the SXM2 base board into the chassis as shown. Figure 307: Installing the SXM2 base board (B) Ê...
Page 417
SXM2 extension tray "Installing the GPGPU / SXM2 extension tray" on page 65 Ê Ê Install all SXM2 extensions, see section "Installing the SXM2 module" on page 378. Ê Install all SXM2 heat sinks, see section "Installing liquid cooling (LC)" on page 379.
Cables Safety notes CAUTION! Always hold cables by their connectors when disconnecting them. ● Never pull on the cable to disconnect cables. Ensure that none of the cables are scraped, strained or otherwise ● damaged while replacing system components. Immediately replace cables with damaged shielding. ●...
Cables 12.1 Cabling overview Ref Part number Name Description A3C40200739 SATA cable for Onboard SATA cable CX2550 M4, CX2560 M4, CX2570 M4 A3C40200741 SAS cable for CX2550 M4, SAS cable from SAS / CX2560 M4, CX2570 M4 RAID card to system board A3C40200716 I2C Cable for GPGPU I2C connection between...
Cables Ref Part number Name Description C17 A3C40204831 ROC Cable I2C cable for Dual microSD 64GB Enterprise (85mm) C20 A3C40170321 FBU cable Used for TFM to FBU (Cougar 4) A3C40200568 (Cougar 5) Table 5: List of used cables 12.2 Cabling Cabling with SATA onboard Figure 308: Cabling with SATA onboard Upgrade and Maintenance Manual...
Page 422
Cables Connecting the SATA cable Figure 309: SATA cable Figure 310: Connecting the SATA cable The air duct must be removed when the SATA cable is routed. Ê Plug the angled end of the SATA cable on the SAS COM1 connector (1) and the other end to the SAS COM2 connector on the system board (2).
Page 423
Cables Figure 311: Running the SATA cable at the SAS COM2 connector Ê After routing the SATA cable, push the SATA cable at the SAS COM2 connector as shown in the three views above (see circles). Cabling with SAS / RAID controller (4+2)x SAS CPU2 CPU1...
Page 424
Cables Connecting the SAS cable Figure 313: SAS cable Figure 314: Connecting the SAS cable to the RAID controller Ê Connect the P1 connector of the SAS cable to #0 port of the SAS / RAID- controller (1). Ê Connect the P2 connector of the SAS cable to #1 port of the SAS / RAID- controller (2) Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 425
Cables Figure 315: Connecting the SAS cable to the system board Ê Connect the single end of the SAS cable to the SAS COM2 connector on the system board (see circle). Figure 316: Routing the SAS cable Ê Route the SAS cable as shown. Ê...
Page 426
Cables Figure 317: Bending and routing the SAS cable Cabling with FBU Figure 318: Cabling with FBU FBU is only supported by CX2560 M4 and CX2570 M4 with air cooling. Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 427
Cables Cabling for GPGPU extension tray (CX2570 M4) Figure 319: Cabling for GPGPU extension tray Cabling of the Omni-Path PHY card signal cable and Omni-Path PHY card sideband cable for CX2550 M4 Figure 320: Omni-Path PHY card signal cable Figure 321: Omni-Path PHY card sideband cable Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 428
Cables Figure 322: Cabling for the Omni-Path PHY card signal and Omni-Path PHY card sideband cable For more information on connecting the cables, see "Replacing the Omni-Path PHY card signal cable and Omni-Path PHY card sideband cable" on page 430. Dongle cable (USB/VGA) Figure 323: Dongle cable (USB/VGA) Upgrade and Maintenance Manual...
Page 429
Cables Cabling for Dual microSD 64GB Enterprise Figure 324: Cabling for Dual microSD 64GB Enterprise Dual microSD 64GB Enterprise is only supported by CX2560 M4 and CX2570 M4. Upgrade and Maintenance Manual CX2550/60/70 M4...
Cables 12.3 Replacing the Omni-Path PHY card signal cable and Omni-Path PHY card sideband cable Field Replaceable Unit Hardware: 10 minutes (FRU) Tools: Preliminary and concluding steps: tool-less Main steps: PH2 / (+) No. 2 screw driver Omni-Path PHY card signal cable and Omni-Path PHY card sideband cable are only available in combination with the CPU type 2.
Cables 12.3.2 Removing the Omni-Path PHY card signal cable and the Omni-Path PHY card sideband cable 12.3.2.1 Disconnecting the Omni-Path PHY card sideband cable from the system board Figure 325: Disconnecting the Omni-Path PHY card sideband cable Ê Disconnect the Omni-Path PHY card sideband cable from the system board (see arrow).
Cables 12.3.2.2 Disconnecting the Omni-Path PHY card signal cable from the CPU type 2 Figure 326: Disconnecting the Omni-Path PHY card signal cable Ê For disconnecting the Omni-Path PHY card signal cable from the CPU, proceed as follows (1): Figure 327: Unlatching the wire bail Ê...
Page 433
Cables Figure 328: Pulling the connector Ê Pull the connector away from the CPU. Figure 329: Removing the connector Ê Remove the connector from the bolster plate. Upgrade and Maintenance Manual CX2550/60/70 M4...
Cables 12.3.2.3 Disconnecting the cables from the Omni-Path PHY card Ê Remove the riser module, see section "Removing the riser module" on page Ê Remove the controller from the riser module, see section "Removing a controller from the riser module" on page 123.
Cables 12.3.3 Installing the Omni-Path PHY card signal cable and the Omni-Path PHY card sideband cable 12.3.3.1 Connecting the cables to the Omni-Path PHY card Ê Remove the riser module, see section "Removing the riser module" on page Figure 331: Connecting the cables to the Omni-Path PHY card Ê...
Cables 12.3.3.2 Connecting the Omni-Path PHY card signal cable to the CPU type 2 Figure 332: Routing the Omni-Path PHY card signal cable under the SATA cable Ê Route the Omni-Path PHY card signal cable under the SATA cable (see circle).
Page 437
Cables Figure 334: Placing the Omni-Path PHY card signal cable connector on the bolster plate Ê Lift the pull tab up (1). Ê Place the connector of the Omni-Path PHY card signal cable on the bolster plate (2). Figure 335: Pushing the connector towards the CPU Ê...
Page 438
Cables Figure 336: Locking the wire bail Ê Push the wire bail into the lock position on the bolster plate and ensure that the pull tab is laid flat. Upgrade and Maintenance Manual CX2550/60/70 M4...
Cables 12.3.3.3 Connecting the Omni-Path PHY card sideband cable to the system board Figure 337: Routing the Omni-Path PHY card sideband cable under the SATA cable Ê Route the Omni-Path PHY card sideband cable under the SATA cable (see circle). Figure 338: Connecting the Omni-Path PHY card sideband cable to the system board Ê...
Cables 12.3.4 Concluding steps Perform the following procedures: "Installing the server node in the server enclosure" on page 67 Ê Ê If applicable, reconnect all external cables. "Switching on the server node" on page 69 Ê "Updating or recovering the system board BIOS and iRMC" on page 77 Ê...
Appendix 13.1 Mechanical overview 13.1.1 Server node interior Figure 339: Example: PRIMERGY CX2560 M4 server node interior (with heat sinks) Pos. Component M.2 SSD (2x) (not visible, located under the riser module Riser module on the left side Memory slots for CPU1...
Appendix 13.1.2 Server node rear Figure 340: Rear connectors of the server node CX2550 / CX2560 M4 1 Management LAN connector A PCIe slot 2 2 Shared LAN connector B PCIe slot 1 3 VGA/USB Dongle cable connector C OCP mezzanine card slot Upgrade and Maintenance Manual CX2550/60/70 M4...
Appendix 13.2 Connectors and indicators 13.2.1 System board connectors and indicators 13.2.1.1 Onboard connectors Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 444
Appendix CPU 2 CPU 1 Figure 341: Internal connectors of system board D3853 / D3854 Upgrade and Maintenance Manual CX2550/60/70 M4...
5 Reset button (RST) 3 CSS indicator The server nodes are controlled via related operating panel areas on the front side of the CX400 M4 server enclosure. See "FUJITSU Server PRIMERGY CX400 M4 Server Enclosure Operating Manual". 13.2.2.1 Control elements Reset button Pressing the reset button reboots the system.
Appendix 13.2.2.2 Indicators on the server node Global Error indicator (orange) – Lights up orange if a prefailure event has been detected that requires (precautionary) service intervention. – Flashes orange if an error was detected that requires service intervention. – Does not light up if there is no critical event. If the event is still acute after a power cycle, the indicator is activated after the restart.
Depending on the settings in the BIOS, the Shared LAN connector may also be used as a Management LAN connector. You will find further information in the "D3853 BIOS Setup Utility for FUJITSU Server Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 451
Appendix PRIMERGY CX2550 M4 Reference Manual" or in the "D3854 BIOS Setup Utility for FUJITSU Server PRIMERGY CX2560 M4 / CX2570 M4 Reference Manual". Upgrade and Maintenance Manual CX2550/60/70 M4...
Appendix 13.3 Minimum startup configuration Field Replaceable Units (FRU) If the server does not start up or other problems occur, it may be necessary to take the system down to its most basic configuration in order to isolate the defective component. The minimum startup configuration consists of the following components and cables: Component...
Page 453
Appendix The minimum startup configuration must be used exclusively for diagnostic purposes by maintenance personnel, never in daily operation! Upgrade and Maintenance Manual CX2550/60/70 M4...
Page 454
Appendix Upgrade and Maintenance Manual CX2550/60/70 M4...