This guide provides basic setup instructions for the EA800-ip
Critical Environment Monitoring System and associated
sensors. Installers should refer to the Installation Manual
(found on-line at www.winland.com) for more
information, specifications, and to become familiar with the
device features. The device allows connection of up to 4 wired
and 8 wireless sensors and has 8 assignable dry contact alarm
loop connections.
Cloud Based Monitoring: The EA800-ip utilizes a cloud
computing architecture, no client software is required.
This version describes features only available on the
system using the firmware version C15f or higher.

SPECIFICATIONS

Device Input Voltage
Wireless Sensor Input Voltage
(EA-WMFS, EA-WTS, EA-WHS)
Device Auxiliary
Output Voltage
Device and Wireless Sensor
Environmental Operating Range
Ambient Environmental Quality
Relay Contact Ratings
Real-Time Clock Battery
Ethernet (wired)
www.winland.com
© Copyright 2016 Winland Electronics, Inc.
D-011-0153 Rev J
INSIGHT
1 1 to 26VDC @ ≤ 500mA current draw
12VDC @ ≤ 100mA current draw via 2.1
mm barrel plug, center positive OR 2 AA
Alkaline Batteries (1.5V Cell)
Equivalent to DC Input Voltage used: 11 to
26VDC. (Maximum output current 0.5A).
Temperature: 0°C to 50°C (32°F to 122°F).
Not for installation inside coolers or freez-
ers. Humidity: 5% to 95% RH, non-
condensing.
Indoor use intended, non-corrosive environ-
ment.
Max 30VDC @ 1 Amp, resistive
CR2032 (3V Cell)
10/100BASE-TX/FX; fully compliant to IEEE
802.3u standard
Winland Electronics, Inc., 1950 Excel Drive, Mankato, MN 56001 USA
(Tech Support 8:00am—5:00pm Central) - (800) 635-4269
F1, F2, F3:
So Keys: Func on changes as determined by the
so ware. Its current func on is displayed above the key on
the LCD screen.
Up Arrow: Provides the scroll up func on. It moves the selec on
cursor up a list or increments the value of alphanumeric entry fields
as iden fied by the flashing cursor.
Enter key: Accepts the currently entered selec on when pressed.
If the selec on is a menu item, the selected item is accessed.
Down Arrow: Provides the scroll down func on. It moves the
selec on cursor down a list or decrements the value of alphanu-
meric entry fields as iden fied by the flashing cursor.
Home key: Displays the home screen (MONITORING) when
pressed from any menu level or from the Menu screen.
Menu key: Displays the MAIN MENU screen when pressed from
any menu level or from the home screen.
Silence key: Temporarily silences the local audible alarm and deac vates
the auxiliary relay for 10 minutes. If a new alarm origina ng from a
different sensor occurs within this 10-minute period, the audible alarm
and aux relay are reac vated, and require another key press to silence
the audible alarm.
Note: Alarms cannot be cleared and will con nue to recur un l the monitored condi ons are within the
programmed parameters.
Note: Local audible alarm can be disabled via local or web programming.

Before Installation

Local device password is 0800.
In order to access the device on the Web Portal the device needs to be
communicating with our host server.
A 30 minute timer starts on the device as soon as power is applied. At
least one (1) sensor must be programmed locally or remotely within the
30 minutes or an alarm will occur. This timer is in place to remind install-
ers the device requires programmed sensors for functionality; it can be
canceled by pressing "timer" (F3 button).
Wired sensor inputs are numbered 1 - 4. Wireless sensors are in posi-
tions 5-12.
Wireless output relays are assignable and numbered 1 - 8.
Wireless sensors must be set up locally at the device to ensure com-
munication.
ANETNNA to communicate with
(up to 8) wireless sensors.
LCD SCREEN
Displays real- me sensor data.
Flashes under alert condi on
USB PORT for local data download

Advertisement

loading
Need help?

Need help?

Do you have a question about the EnviroAlert EA800-ip and is the answer not in the manual?

Questions and answers

Summary of Contents for Winland EnviroAlert EA800-ip

  • Page 1: Quick Start Guide

    Ethernet (wired) 10/100BASE-TX/FX; fully compliant to IEEE • Wireless sensors must be set up locally at the device to ensure com- munication. 802.3u standard Winland Electronics, Inc., 1950 Excel Drive, Mankato, MN 56001 USA (Tech Support 8:00am—5:00pm Central) - (800) 635-4269...
  • Page 2 IEEE 802.3u frequent traffic as abnormal and cause the connection to be shut down. To standards. avoid connection trouble, check with your network administrator. Winland Electronics, Inc., 1950 Excel Drive, Mankato, MN 56001 USA (Tech Support 8:00am—5:00pm Central) - (800) 635-4269...
  • Page 3: Set Date And Time

    Set Date and Time INSTALL OVERVIEW (continued) NOTE: When connected to the Winland Web Servce, the Date and Time are set automatically and cannot be changed. To manually set the Date Troubleshoot Internet Connection and Time when not using INSIGHT , the “Cloud”...
  • Page 4: Advanced Settings

    Select the type of probe to be connected to the Advanced Settings wireless multi-function sensor, then press: Refer to the Installation Manual found online at www.winland.com for Assign a Common name or Custom name to the probe, and continue to follow configuring the following advanced EA800-ip settings: on-screen prompts to complete the setup.