Page 1
Super Camaro M-022LS Oasis Twilight/Sapphire DO NOT RETURN MERCHANDISE TO YOUR DEALER STORE DIRECTLY. CALL MSPA AFTER SALES SERVICE CENTER FOR PRODUCT QUESTIONS OR CONTACT MSPA AT info@the-mspa.com Due to MSpa continuous product improvement, MSpa reserves the right to change specifications and product appearance, which may result in updates to the instruction manual without notice.
To guide you in your initial MSpa experience, we are pleased to present you with this instruction manual. Please carefully and thoroughly read this manual entirety before using the product for the first time. We are delighted to welcome you to the MSpa family, and look forward to sharing with you the full spectrum of our expertise.
SAFETY PRECAUTIONS For your own safety and that of your product, make sure to follow the safety precautions below. Fail to follow the instruction may result in serious injury, property damage or death. Improper installation or operation will void the warranty. READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS DANGER ●...
Page 4
● Residential electrical connection box must be located safely with a distance of at least 2m away from the spa. ● Electric installation should fulfill the local requirement or standards. ● Do not press down or uplift the control panel or put any heavy items on the control panel after installations.
Page 5
several degrees above the normal body temperature 37°C(98.6°F). The symptoms of hyperthermia include an increase in the internal temperature of body, dizziness, lethargy, drowsiness, and fainting. The effect of hyperemia include failure to perceive heat; failure to recognize the need to exit spa; unawareness of impending hazard;...
Page 6
For water already used, discharge it in time or use water chemicals for cleaning. Usually,change water every 3-5 days. ● Use Mspa chemical kit for disinfection in accordance with manufacture's instructions. ● Do not leave or set up the spa in temperature lower than 4°C(39°F) if heater is not operating.
Page 7
Warning: Water protection levels of appliance at different product zones are different see the following scheme. ( Installation regulations comply to IEC 60364-7-702) 2.5 m Zone 2 Zone 1 Zone 2 2.5 m Zone 0 Zone 0 1.5 m 2.0 m 2.0 m 1.5 m NOTE-The measured zone dimensions are limited by walls and fixed partitions.
Page 9
PRODUCT OVERVIEW Packaging content ® ® * Only for Nest M-001LS ONLY FOR ALPINE M-009LS/019LS * Buckle spa cover * Ground mat * Only for Glow M-022LS NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale.
REF. NO. PARTS DESCRIPTION QTY. Spa cover with aluminum foil inside (Alpine M-009LS/019LS comes with a ground mat with the cover) Spa tub Control panel with air pipe Digital lock (except for Alpine M-009LS/019LS) Inflation hose Manometer Filter cartridge Spa drain valve adaptor Repair kit Wrench Wicker side bar (Only for Nest M-001LS)
Page 11
Additional requirements for indoor installation ● Verify the supporting floor can support the filled weight of spa with maximum number of occupants. Check with a qualified contractor or structural engineer to verify the requirement. ● Make sure the floor is water resistant and provides non-slip surface. Do not install the spa on a carpet of any other material that could damaged by the moisture.
(*For missing or damaged part, contact the MSpa Service Center) NOTE: The heat preservation ground mat is not for the MSpa LITE except for Alpine M-009LS/019LS. It is recommended to apply a ground mat for the spa tub to prevent scratches or heat loss.
Page 13
Connect the digital cable on the control panel. "ON/OFF" button shows red if the connection correctly, No bent or wet for the pin inside male connector which will cause failure connection. Connect the control panel to the spa tub. Fasten and secure the rings to the pipe adapter on the spa tub. Make sure the rubber O-rings are properly placed on the air pipes.
Page 14
Yellow Green Button Over Inflation 5.6 When inflation is completed. Press Bubble button again to turn it off. Disconnect the inflation hose on both ends. Replace the air valve cap back. NOTE: ● The cap is designed to be screwed on and off. Never exert force as this could cause the complete internal inflation system of the valve to come loose.
Page 15
6.5 Turn on the Heater on the spa control panel, refer to the “Control Panel Operation” section. Maximum heating temperature is 42°C(108°F). Hourly heating rate is about 2°C-2.5°C(3.5°F-4.5°F) for 2 and 2+2 persons, 1.5°C-2°C(2.5°F-3.5°F) for 4 persons and 1.2°C-1.8°C(2°F-3°F) for 6 persons.
CONTROL PANEL OPERATION 4 3 2 1. ON/OFF Button 2. Bubble Button 3. Filter Button 4. Heater Button 5. UP & DOWN Button ON/OFF Button: To activate the control panel. ON/OFF Default stand by mode shows red when the power is on. Press again, the control reaches operative mode and turns to green.
Step 2: Connect the power supply, press REST button on the PRCD. System failure Step 3: If E3 shows, contact the MSpa Service Center. If E3 is flashing, press ON/OFF and BUBBLE buttons together, enter to the self-checking system.If no error...
Page 18
CAUTION: ● Always follow the chemical manufacturer’s direction, and the health and hazard warning. ● Do not add chemicals if the spa is occupied. This can cause skin or eye irritation. ● Concentrated chlorine solutions can damage the spa tub. Improper chemical use will void the warranty. Maintenance of Spa Water and Cartridge Protect all the spa occupants from possible water related illness by keeping the spa water clean and sanitized.
Page 19
MSpa Water Treatment Kit MSpa Water Treatment Kit (* Optional) ● B0301858 MSpa Chemical Starter Kit (20 X 20g Bromine Tablets + 500ml Algaecide + Floating Dispenser) Disinfectant for water spas and pools. disinfectant, algaecide and bactericide.
DRAINAGE, CLEANING AND STORAGE Spa Drainage 1. Turn off all the buttons (heater, filter and bubble) on the control panel unit. 2. Connect the drain valve adapter to a garden hose and point the other end of the garden hose to a suitable draining area with local environmental regulations (Fig.1) 3.
NOTE: Glue is not included. pin hole pin hole Storage and Prepare for the Next Time Use 1. Drain and clean the spa by following the “Drainage” and “Spa Cleaning” sections 2. Reserve the set up instructions to deflate and disassemble the spa tub, spa control unit and air bladder 3.
Spa inlet/outlet connection not Tighten the inlet and outlet securely tight connection Drainage valve is not closed Contact the MSpa Service Center, if spa is SPA LEAKING completely still leaking Water leaks from the spa Repair the leaking hole/spilt with the repair...
Page 23
Increase filtration time WATER NOT CLEAN Dirty filter cartridge Clean or replace the filter cartridge in time Refer to the chemical manufacture’s Improper water maintenance instruction CONTACT YOUR LOCAL MSPA DEALER OR SERVICE CENTER FOR ANY PRODUCT RELATED QUESTIONS OR PROBLEMS.
The warranty period begins on the date of purchase and MSpa requires presentation of the original proof to purchase to ascertain the date. During the warranty period, MSpa will either repair or replace, at its discretion, any defective products. Replacement products or repaired parts will be warranted for only the unexpired portion of the original warranty.