Download Print this page

Mitsubishi Electric FR-A800 Instruction Manual page 8

Hide thumbs Also See for FR-A800:

Advertisement

●Wiring and ferrule terminal specifications
Cable gauge (mm
0.3
0.5
0.75
1
1.25 / 1.5
0.75 (for two wires)
∗1 Ferrule terminals and the tool are distributed by Phoenix Contact Co., Ltd.
●Shorting wire
The shorting wire are installed between terminals S1/S2 and PC and between terminals SIC and SD in the initial
status as shown in Figure 3.
Before connecting the wires for the safety stop function to terminals S1, S2, and SIC, remove the shorting wires.
8
INSTALLATION AND WIRING
Table 5 Wiring and Ferrule terminal specifications
2
Ferrule terminal model
)
AI 0,34-10TQ
AI 0,5-10WH
AI 0,75-10GY
AI 1-10RD
AI1,5-10BK
AI TWIN 2 X 0,75-10GY
2
5
4
1 F/C +24 SD
So SOC
AM
5 10E 10 SE SE
RUN
SU
IPF OL FU
Figure3 Shorting wire
∗1
CRIMPFOX 6
SD
SIC
S1 S2 PC
A1
B1
C1
PC RL RM RH RT AU
STP MRS RES
SD SD
Crimping tool name
A2
B2
C2
STF STR JOG
CS
∗1

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Fr-f800