Mass Energy ME 3000SP User Manual

Energy storage inverter
Hide thumbs Also See for ME 3000SP:

Advertisement

 
 
Ene
ergy S
Storag
User
U
(M
ME 3000
ge Inv
r Ma
anua
0SP)
 
 
2017‐05‐
‐12
V1.5
verter
al
 
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ME 3000SP and is the answer not in the manual?

Questions and answers

William John Carter
February 28, 2025

I have no display information on the inverter, just a blank screen

1 comments:
Mr. Anderson
February 28, 2025

The Mass Energy ME 3000SP inverter may not display information due to the following reasons:

1. Power Supply Issue – The inverter may not be turned on, or the DC & AC breakers may be off. Ensure the inverter is powered.
2. Connection Issue – If the CT connection has been changed, the setup procedure must be repeated.
3. Firmware Update Issue – If a firmware update fails, the inverter may not function properly. Ensure the update completes successfully and restart the inverter.
4. Screen Failure – If the LCD screen does not turn on after power is supplied, there might be a hardware malfunction.

Check power connections, restart the inverter, and verify successful firmware updates to resolve the issue.

This answer is automatically generated

Summary of Contents for Mass Energy ME 3000SP

  • Page 1   ergy S Storag ge Inv verter User r Ma anua ME 3000 0SP)       2017‐05‐ ‐12 V1.5  ...
  • Page 2      ...
  • Page 3: Table Of Contents

      Contents     1.  ME3000SP Introduction  ............................  5   2.  Safety Notes  ................................  6   2.1  Safety Notes  .............................  6   2.2  Battery Installation and Maintenance Notes  ...................  6   3.  Installation ................................  8   3.1  Product Overview ............................  8   3.2  Packing List ..............................  9   3.3 ...
  • Page 4   6.4.1  Parameter setting: ..........................  2 5  6.4.2  Event List  ..............................  3 3  6.4.3  System information interface ........................  3 3  6.4.4  Software upgrade ..........................  3 4  6.4.5  Energy Statistics: ..........................  3 5  7.  Technical Data  ................................  3 6  8.  Troubleshooting  ..............................  3 7   ...
  • Page 5: Me3000Sp Introduction

        1. ME3000SP Introduction    ME3000SP is an AC coupled bi‐directional battery inverter. The customer can purchase batteries & ME3000SP  as an energy storage add‐on to his/her existing renewable energy system. It can help to achieve optimal usage of  renewable  energy.  ME  3000SP  can  control  the  bi‐directional  flow  of  electric  power,  work  under  auto  /  manual  &  time‐of‐use (TOU) modes, charge / discharge the battery as per customer’s setting.   In  auto mode,  ME3000SP  will  store  surplus renewable  energy  into the  battery  &  discharge battery  to supply  power  to  local  load  when  renewable  energy  is  not  enough.    ME3000SP  is  equipped  with  an  LCD  display  and  4  buttons, friendly human machine interaction system. More importantly ME3000SP is stable, safe, and reliable.  ...
  • Page 6: Safety Notes

        2. Safety Notes    Before installation, please make sure you read & understand this manual. ME3000SP strictly meets safety rules  of  design  and  testing.  During  the  installation,  operation  and  maintenance,  operators  should  abide  by  local  safety  regulations. Improper operation may cause an electric shock or damage the equipment and properties.   2.1 Safety Notes    Electrical  installation  and  maintenance  must  be  carried  out  by  competent  electricians  according  to  local  regulations. ...
  • Page 7    Keep  the  battery  away  from  direct  sunshine.  Don’t  put  battery  close  to  a  furnace  or  fire  to  avoid  battery  leak/explode.   The current capacity of power cables (from battery to inverter) should be at least 70A. Use short power cables  to avoid high voltage drop & power loss.   Use  a  multimeter  to  check  the  batter  voltage  &  polarity  before  switching  on  the  batteries.  Make  sure  connections are correct according to this manual. ...
  • Page 8: Installation

      3. Installation    3.1 Product Overview ME3000SP is 100% strictly inspected before package and delivery. It is forbidden to put ME3000SP upside down  during delivery.   Please check the product package and fittings carefully before installation.   Fig. 2 ME3000SP Overview   ...
  • Page 9: Packing List

      3.2 Packing List Inspect the package and fittings carefully before installation. You should have the following fittings:  Mounting Bracket × 1 AC terminal × 6 M5 screw × 2 Battery terminal × 2 M6 flat washer × 8 CT terminal × 2 Terminal cap × 4 Expansion Bolts × 8 User Manual × 1 Warranty card ×...
  • Page 10: Installation Tools

       ME3000SP shall be connected to the electrical grid with an overvoltage category III or category II.   Maximum altitude: 2000m.    3.4 Installation Tools The following tools shall be prepared before installation:  Tool Model Function Hammer drill  1  Used to drill holes on the wall  Recommend drill dia.6mm    2  Screwdriver  wiring    3  Wire stripper  Strip wire    Turn the screw to connect rear panel  4  4mm Allen Key  with inverter    5  Crimping tools  Used to crimp power cables    6  Multi‐meter  Used to check grounding    7  Marker pen ...
  • Page 11: Installation Position

      Used t to ensure that t the rear pan nel is  9  Leve el  properly i nstalled    10  ESD glo oves  Operator rs wear    11  Safety go oggles  Operator rs wear    12  Anti‐dust re espirator  Operator rs wear    3.5 Inst tallation Position ME3000SP  should be ve ertically mou nted (to ensu ure fast heat  dissipation),  please choo ose a position n without dire ect ...
  • Page 12     Step 4: Put ME3000SP on the mounting bracket.  Step 5: Earth ME3000SP using the grounding hole on the heat sink.   Step 6: OPTIONAL: you can lock ME 3000SP               Step 5                Step 6         ...
  • Page 13: Electrical Connection

      4. Electrical Connection    Be aware of electric shock and chemical hazards!   Before  connecting  the  battery,  ensure  the  cable  connectors  have  the  correct  polarity.  Reversed  polarity  can  damage ME3000SP!   It’s recommended to install a rotary DC isolator (100A) between ME3000SP and batteries. Thus ME3000SP can  be securely disconnected during installation/maintenance.   It’s necessary to install a AC circuit breaker (25A) between ME3000SP and electrical grid.   It is very important for system safety and efficient operation to use appropriate cable for electrical connection.   Battery connection:  AWG6 cable.    Grid & Load connection: AWG12 cable.    Make sure N wire is connected to PE wire while EPS (Emergency Power Supply) mode is enabled.    Fig. 5 Wiring Schematic of Single Phase System    ...
  • Page 14: Battery Connection

      4.1 Battery Connection   Fig. 6 Battery connection (Test battery wires polarity before connection)    Step 1: Loosen 4 screws (A) using a screwdriver (fig. 6);  Step 2: Remove the waterproof cover (B), loosen the cable gland (C), and then remove the stopper (G);  Step 3: Route the battery wires (F) through the cable gland, then connect battery wires using OT terminal (E);  Step 4: Fasten the waterproof cover using 4 screws.    4.2 CT / RS485 / NTC connection    ...
  • Page 15     Fig. 7 Schem matic Diagram m (ME 3000SP P: energy stor rage add‐on t o existing ren newable syste em)    Step 1: Loca ation of CTa:  L wire of inco oming mains.  Location of C CTpv: L wire o of PV inverter ’s output.  Step 2: Use e network cab ble & termina l caps to exte end CT wires.   Fig. . 8 CT wire ex xtension    T wire Extensio on cable (netw work cable) 3000SP Orange / white e orange / bro own / white br rown...
  • Page 16: Ct / Rs485 / Ntc Connection  1

                  Fig. 9 CT / RS485 / NTC connection    Step 3: Loosen 4 screws (part A) using a screwdriver (fig. 9)  Step 4: Remove the waterproof cover (part B), loosen the cable gland (part C), then remove the stopper (part G)  Step  5:  Route  CT  cable  through  the  cable  gland,  connect  CT  cable  to  CT  terminal,  then  insert  CT  terminal  into  corresponding ports.  Step 6: one communication cable is provided in the ME3000SP accessory bag. One inverter end, one battery end.  Route  the  communication  cable  (inverter  end)  through  the  cable  gland,  insert  the  4P4C  connector  to  485M/CAN  port. ...
  • Page 17: Grid Connection

      Step 7: Connect NTC for lead acid batteries only:     Fig. 10 NTC connection  Step 7: fasten the waterproof cover using 4 screws.  4.3 Grid Connection For most of the customers, please ONLY connect the GRID port.   Please leave LOAD port unconnected.   Unless you need the EPS (Emergency Power Supply) function.  Step 1: Loosen 4 screws (part A) using a screwdriver (fig. 11)  Step 2: Remove the waterproof cover (part B), loosen the cable gland (part C),  then remove the stopper (part G)  Step 3: Route a 3‐core cable through GRID cable gland, then connect 3 wires to  corresponding terminal blocks. (BROWN – L, BLUE – N, YELLOW/GREEN – PE)  Step 4: Fasten the waterproof cover using 4 screws.    Fig. 11 Grid & Load connection   ...
  • Page 18: Critical Load Connection (Eps Function)

      4.4 Critical Load Connection (EPS function) Critical  load:  in  case  of  grid  outage,  ME  3000SP  will  work  in  EPS  (Emergency  Power  Supply)  mode,  discharge  the  battery & supply power to critical load via LOAD port.  LOAD port is only for critical load connection. Please make sure you’ve purchased the AC contactor from Shenzhen  SOFARSOLAR Co., Ltd.  The connection procedure of LOAD port is the same as grid connection (Fig. 11).          Fig. 12 AC contactor front view, top view, and connection      Fig. 13 Critical load connection (AC contactor: 2 NC, 2 NO)       ...
  • Page 19: Indicator Lights And Buttons

      5. Indicator lights and buttons    5.1 Buttons:  press “Back” to the previous screen or enter the main interface;   press “Up” to the upper menu option or value plus 1;    press “Down” to the lower menu option or value minus 1;   Press “OK” to select the current menu option or switch to the next digit.  5.2 Indicator lights:  Discharging status Light(Green)   Discharging light flashing: system check before discharging the battery   Discharging light ON: discharging the battery   Discharging light OFF: system is faulty (fault, or permanent)   Charging status Light(Green)   Charging light flashing: system check before charging the battery   Charging light ON: charging the battery   Charging light OFF: system is faulty (fault, or permanent)   Alarm light(Red)  Alarm light ON: system is faulty (fault, or permanent)    ...
  • Page 20: Status Of Me3000Sp

        5.3 Status of ME3000SP Status of  Discharging  Charging  Alarm  ME3000SP  Green Indicator light  Green Indicator light  Red Indicator light Discharge  ON      Charge    Standby  Flashing Flashing   EPS state  ON  ON    Fault      ON         ...
  • Page 21: Operation

      6. Operation  6.1 Double Check Please double check the following before operation.  1. ME3000SP is firmly fastened to the mounting bracket on the wall;  2. The polarity of battery wires is correct, battery wires are firmly connected;  3. DC isolator is correctly connected between battery & ME3000SP, DC isolator: OFF;  4. GRID / LOAD cables are firmly / correctly connected;  5. AC circuit breaker is correctly connected between ME3000SP GRID port & GRID, AC circuit breaker: OFF;  6. AC contactor is correctly connected (fig. 12);  7. For lithium battery, please ensure that the communication cable has been correctly connected;  8. For the lead‐acid battery, please ensure that the NTC wire has been correctly connected.  6.2 First Time Setup (important!) IMPORTANT: PLEASE FOLLOW THE FOLLOWING PROCEDURE to switch ON ME3000SP  Turn OFF PV inverter. Make sure there’s no power generation in ME3000SP’s phase.  Turn ON DC isolator between battery & ME 3000SP.    Turn ON AC circuit breaker between ME 3000SP GRID port & GRID. ME 3000SP should start to operate now.    You need to set the following parameters before ME3000SP start to operate.  1)Set system time  8)Set min discharge voltage  2)Set country  9)Set max discharge current  3)Select battery type  10)Set min protect voltage 4)Set battery capacity ...
  • Page 22   5)Set max charge voltage  12)Set empty discharge voltage  6)Set max charge current 13)Set full charge voltage 7)Set max protect voltage 1)Set system time  The format of System time is “YYYY‐MM‐DD‐HH‐MM‐SS”, press “Up” or “Down” to change the 1  digit, press “OK”  to switch to next digit, press “Ok” to complete the time setting. When the system setting is complete, then it will  enter “country” setting automatically.  2)Set country  Press  “Up”  or  “Down”  to  select  a  country,  press  “Ok”  to  complete  the  country  setting,  then  it  will  enter  “battery  type” setting automatically.  CODE  Country  CODE Country  00  Germany4105  Germany_0126  01 ...
  • Page 23   4.DEFAULT  LEAD ACID / AQUION    Recommended settings for customers using PYLONTECH US2000B batteries:  Batteries parallel number  1 x US2000B  2 x US2000B  3 x US2000B  4 x US2000B  Battery type  PYLON  PYLON  PYLON  PYLON  Battery capacity  50Ah  100Ah  150Ah  200Ah  Max charge voltage  53.2V  53.2V  53.2V  53.2V  Max charge current  25.0A  50.0A  60.0A  60.0A  Max protect voltage  54.0V  54.0V  54.0V  54.0V  Min discharge voltage  47.2V  47.2V  47.2V  47.2V  Max discharge current ...
  • Page 24: Commissioning

      current per your battery specification, press “Ok”, then it will enter “min protect voltage” setting automatically.  10)Set min protect voltage  Press  “Up”  or  “Down”  to  change  the  1   digit,  press  “OK”  to  switch  to  next  digit.  After  inputting  the  min  protect  voltage per your battery specification, press “Ok”, then it will enter “discharge depth” setting automatically.  11)Set discharge depth  Press “Up” or “Down” to change the 1  digit, press “OK” to switch to next digit. After inputting the discharge depth  per your battery specification, press “Ok”, then it will enter “empty discharge voltage” setting automatically.  12)Set empty discharge voltage (valid for lead acid battery only)  Press “Up” or “Down” to change the 1  digit, press “OK” to switch to next digit. After inputting the empty discharge  voltage per your battery specification, press “Ok”, then it will enter “full charge voltage” setting automatically.  13)Set full charge voltage (valid for lead acid battery only)  Press  “Up”  or  “Down”  to  change  the  1  ...
  • Page 25: Main Menu

      The main interface:   6.4 Main Menu At the standard interface, press the “back” button to enter the main menu. The main menu includes five options:  parameter settings, event list, system information, software upgrade, and energy statistics.   Main Menu  1.Enter Setting  2.Event List  3.System Information  4.Software Update  5.Energy Statistics 6.4.1 Parameter setting:  1.Enter Setting  1.Batt Parameter  7.Set Language 2.Clear Energy Data 8.Set Time 3.Clear Events  9.Set EPS Mode  4.Set Country  10. DRMs0 Control  5.Set Communication Add  11. Auto Test 6.Function to Set Country  12. Work Mode Set  ...
  • Page 26   1. Batt Parameter 1.Batt Parameter  1.Battery Type 7.Max. Discharge (A)  2.Battery Capacity 8.Low (V) Protection  3.Discharge Depth  9.Max. Charge (V)  4.Max. Charge (A)  10.Empty Charged Voltage  5.Over (V) Protection 11.Full Charged Voltage  6.Min. Discharge (V) Press “back” button to enter main menu, select “1. Enter Setting”, Press “OK”. Select “1. Batt Parameter” and  press “OK”, “input password” is shown, press “OK” again. Input the password (normal “0001”,  advanced ”0715”), press “Up” or “Down” to change the 1  digit, press “OK” to switch to next digit, when “0001  / 0715” is shown on the screen, press “OK” to enter “Batt Parameter” interface. If “Error! Try again” is shown  on the screen, press “Back” and input the password again.   1) Battery Type (refer to page 17)  Select “1. Battery Type” and press “OK”. Press “up” or “down” to select the battery type. Press “OK”.  2) Battery Capacity  Select “2. Battery Capacity” and press “OK”. Press “up” or “down” to change the 1  digit, press “ok” to switch to  next digit. Input the value of battery capacity. Press “OK”.  3) Discharge Depth  Select “3. Discharge Depth” and press “OK”. Press “up” or “down” to change the 1  digit, press “ok” to switch to  next digit. Input the value of Depth of Discharge per battery specification. Press “OK”.  For  example:  if  Depth  of  Discharge  =  80%,  ME  3000SP  won’t  discharge  the  battery  when  its  SOC  (State  of  Charge) is less than 20%. ...
  • Page 27   Select “8. Low (V) Protection” and press “OK”. Press “up” or “down” to change the 1  digit, press “ok” to switch  to next digit. Input the value of Low (V) Protection per battery specification. Press “OK”.  9) Max. Charge (V)  Select “9. Max. Charge (V)” and press “OK”. Press “up” or “down” to change the 1  digit, press “ok” to switch to  next digit. Input the value of Max. Charge (V) per battery specification. Press “OK”.  10) Empty Charged Voltage (only valid for lead acid batteries)  Select “10. Empty Charged Voltage” and press “OK”. Press “up” or “down” to change the 1  digit, press “ok” to  switch to next digit. Input the value of Empty Charged Voltage per battery specification. Press “OK”.  11) Full Charged Voltage (only valid for lead acid batteries)  Select  “11. Full  Charged  Voltage”  and  press  “OK”.  Press “up”  or  “down”  to  change the  1   digit, press  “ok”  to  switch to next digit. Input the value of Full Charged Voltage per battery specification. Press “OK”.  2. Clear Energy Data Select  “2.  Clear  Energy”  and  press  “OK”,  “input  password”  is  shown,  press  “OK”  again.  Input  the  password  “0001”, press “Up” or “Down” to change the 1  digit, press “OK” to switch to next digit, when “0001” is shown ...
  • Page 28 9. Set EPS (Emergency Power Supply) Mode MENU  1.Enable EPS Mode  1.EPS Mode Control 9. Set EPS Mode 2.Disable EPS Mode  2.Set EPS Changeover Time *** seconds  10. DRMs0 Control (This part is valid for Australian Market ONLY) Select  “10.  DRMs0  Control”,  press  “OK”,  “input  password”  is  shown,  press  “OK”  again.  Input  the  password “0001”, press “Up” or “Down” to change the 1  digit, press “OK” to switch to next digit, when “0001” is shown on the screen, press “OK”. ...
  • Page 29 Testing 27.S2... ↓ Wait Test 27.S2 OK! ↓ Wait Testing 81>S1... ↓ Wait Test 81>S1 OK! ↓ Wait Testing 81>S2… ↓ Wait Test 81>S2 OK! ↓ Wait Testing 81<S1... ↓ Wait Test 81<S1 OK! ↓ Wait Testing 81<S2... ↓ Wait Test 81<S2 OK! ↓ Press “Ok” Auto Test OK!  ↓ Press “Down” 59.S1 threshold 253V 900ms ↓ Press “Down” 59.S1: 228V 902ms ↓ Press “Down” 59.S2 threshold 264.5V 200ms ↓...
  • Page 30   81>.S1 49.9Hz 103ms ↓ Press “Down” 81>.S2 threshold 51.5Hz 100ms ↓ Press “Down” 81>.S2 49.9Hz 107ms ↓ Press “Down” 81<.S1 threshold 49.5Hz 100ms ↓ Press “Down” 81<.S1 50.0Hz 105ms ↓ Press “Down” 81<.S2 threshold 47.5Hz 100ms ↓ Press “Down” 81<.S2 50.1Hz 107ms 2) Autotest STD  After  entering  Auto  Test  interface,  press  “up”  or  “down”  to  select  “2.Autotest  STD”,  then  press  “OK”  to  start  Auto test STD. ...
  • Page 31   12. Work Mode Set Select “12. Work Mode Set”, press “OK” to enter work mode setting interface.  12.Work Mode Set  1.Set Auto Mode 2.Set Time‐of‐use Mode 3.Set Timing Mode 1) Set Auto Mode  Select “1. Set Auto Mode”, then press “OK”.  In auto mode, the device will automatically determine the charging time & discharging time, & ensure that the  battery SOC (State of Charge) won’t be too low.  Δ PV  generation  =  LOAD  consumption  ( P  <  100W), ME  PV generation > LOAD consumption, the surplus power will be stored in the battery firstly.  3000SP will stay in Standby state.  When  the  battery  is  full(or  already  at  Max  Charge  PV  generation  <  LOAD  consumption,  discharge  the  Power), excess power will be exported to the grid. ...
  • Page 32   3000SP will import power from the grid.  information, press “UP” to get back to main interface.      2) Set Time‐of‐use Mode  Select “2.Set Time‐of‐use Mode”, and then press “OK” to enter Set Time‐of‐use mode interface. End user can set  a  off‐peak  time  period  (evening  charging  time  period)  and  target  SOC  (State  Of  Charge  to  terminate  evening  charging).  The  interface  of  Time‐of‐use  Mode  is  shown  as  below.  This  mode  is  for  customers  who  have  TOU  (Time‐of‐use) pricing electricity (cheaper rate in off peak time & more expensive rate in peak time) and  owning ...
  • Page 33: Event List

    3) Set Timing Mode Select “3. Set Timing Mode”, and then press “OK” to enter Set Timing mode interface. End user can set an off‐ peak  period  (evening  charging  time  period)  &  a  peak  time  period  (daylight  discharging  time  period)  &  corresponding powers. The  interface  of Set Timing  Mode is shown  as below. This mode is for customers who  have TOU (Time‐of‐use) pricing electricity (cheaper rate in off peak time & more expensive rate in peak time).  Charge Start           22 h 00 m  Charge End           05 h 00 m  Charge Power           2000 W  DisCharge Start        14 h 00m  DisCharge End        16 h 00m  DisCharge Power    2500 W  6.4.2 Event List  2.Event List 1.Current Event List ...
  • Page 34: Software Upgrade

    1.Product SN  8.Work Mode  2.Software Version 9. DRMs0 Control 3.Hardware Version 10.Batt Parameter 4.RS485 Address 11.Setting Pf time 5.Country  12.Setting QV time  6.Power Factor 13. Default Pf time 7.EPS Mode 14. Default QV time 6.4.4 Software upgrade  Select “4. Software Update” in the main menu, press “OK”, “input password” is shown, press “OK” again. Input the  password (”0715”), press “Up” or “Down” to change the 1  digit, press “OK” to switch to next digit, when “0715” is  shown on the screen, press “OK”. ME 3000SP will start to upgrade the software automatically.  Upgrading Procedure: Step 1 Turn off AC circuit breaker (grid) and DC isolator (battery), then remove communication waterproof cover. If  communication cables (RS485/NTC/CT) have been connected, loosen their cable glands before removing cover.  Step 2 Press the SD card and take it out. Insert the SD card into a micro‐SD card reader, then insert micro‐SD card  reader into a PC; (NOTE: micro‐SD card reader & PC are not provided by SOFARSOLAR).  Step 3 Format  the  SD  card.  Copy  the  “ES3000firmware”  folder  to  the  SD  card.  (ask  our  technical  support  service@sofarsolar.com to send you the latest software) ...
  • Page 35: Energy Statistics

    Step 7 After  the  update  is  complete,  turn  OFF  AC  circuit  breaker  (grid)  and  DC  isolator  (battery),  lock  the  communication waterproof cover with four screws, then turn ON DC isolator (battery), wait 5 seconds, turn ON AC  circuit breaker (grid), ME 3000SP will start to operate automatically.  NOTE: If “DSP communicate fail”, “Update DSP1 Fail” of “Update DSP2 Fail” is shown on the screen, which means the  software upgrade is unsuccessful, please turn OFF AC circuit breaker (grid) and DC isolator (battery), wait 2 minutes,  then start again from “Step 5”  6.4.5 Energy Statistics:  5.Energy Statistics Today Renewable            100.00KWh  Self‐Use     80.00KWh          80%    Export             20.00KWh             20%  For Load            100.00KWh  Self‐Use     80.00KWh          80%    Import         ...
  • Page 36: Technical Data

      7. Technical Data       ...
  • Page 37: Troubleshooting

      8. Troubleshooting  Code  Name  description  solution  If  the  alarm  occurs  occasionally,  the  possible cause  is  that  the  electric  grid  is  abnormal  occasionally.  ID01  GridOVP  The power grid voltage is too high    ME3000SP  automatically  returns  to  normal  operating  status  when  the  electric  grid’s  back  to  normal.  ID02  GridUVP ...
  • Page 38   ID22  HwAuxPowerFault  The auxiliary voltage error  ID25  LLCBusOVP  LLCBus voltage is too high   Bus  voltage  is  too  high  and  has  ID26  SwBusOVP  triggered software protection   If  the  fault  occurs  frequently,  please  contact  ID27  BatOCP  Battery current is too high   technical support.  ID28‐ID55 are internal faults of ME3000SP, turn OFF  ID28  DciOCP  The DCI is too high   the  ”DC&AC  switch”,  wait  for  5  minutes,  then  turn  ON ...
  • Page 39   ID75  unrecoverEEPROM_W  The EEPROM is unrecoverable  ID76  unrecoverEEPROM_R  The EEPROM is unrecoverable  ID77  unrecoverRelayFail  Relay has happen permanent fault  1.  Please  make  sure  ME  3000SP  in  installed  in  a  place without direct sunlight/other heat source.  ID81  Over temperature  Internal temperature is too high.  2.  Please  make  sure  the  inverter  is  vertically  installed & the ambient temperature is less than the  temperature upper limit of ME3000SP  ID82  Over frequency  AC frequency is too high    This  is  only  an  indication  of  low  battery  voltage  (normally means low battery SOC) ...