10.2.3 The TRACE Function

The TRACE function allows the control of the logic states of PLC operands (M,I,O,T,C) within the
corresponding PLC files (statement list).
Furthermore, the contents of byte, word and double word can be checked.
Call
The statement list (STL) of the converted program is displayed. In addition, the contents of the
operand and the accumulator is displayed in HEX or decimal code for every program line (can be
selected via soft key). Each cyclically executed command is identified with a C.
10 – 84
Soft key to call the TRACE function.
Call the program management.
Select the file to be checked.
Set the display to the program part to be checked (e.g., with the GOTO key, the FIND soft key,
with the cursor keys, etc.).