Mitsubishi Electric FR-A700 Installation Manualline page 35

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

PARAMETER LIST
Parameter
Name
Regeneration avoidance at
884
deceleration detection
sensitivity
Regeneration avoidance
885
compensation frequency
limit value
Regeneration avoidance
886
voltage gain
888
Free parameter 1
889
Free parameter 2
Cumulative power monitor
891
digit shifted times
892
Load factor
Energy saving monitor
893
reference (motor capacity)
Control selection during
894
commercial power-supply
operation
Power saving rate reference
895
value
896
Power unit cost
Power saving monitor
897
average time
Power saving cumulative
898
monitor clear
Operation time rate
899
(estimated value)
C0
FM terminal calibration
(900)
C1
AM terminal calibration
(901)
C2
Terminal 2 frequency setting
(902)
bias frequency
C3
Terminal 2 frequency setting
(902)
bias
125
Terminal 2 frequency setting
(903)
gain frequency
C4
Terminal 2 frequency setting
(903)
gain
C5
Terminal 4 frequency setting
(904)
bias frequency
C6
Terminal 4 frequency setting
(904)
bias
126
Terminal 4 frequency setting
(905)
gain frequency
C7
Terminal 4 frequency setting
(905)
gain
C12
Terminal 1 bias frequency
(917)
(speed)
C13
Terminal 1 bias (speed)
(917)
C14
Terminal 1 gain frequency
(918)
(speed)
C15
Terminal 1 gain (speed)
(918)
C16
Terminal 1 bias command
(919)
(torque/magnetic flux)
C17
Terminal 1 bias (torque/
(919)
magnetic flux)
C18
Terminal 1 gain command
(920)
(torque/magnetic flux)
C19
Terminal 1 gain (torque/
(920)
magnetic flux)
C38
Terminal 4 bias command
(932)
(torque/magnetic flux)
C39
Terminal 4 bias (torque/
(932)
magnetic flux)
C40
Terminal 4 gain command
(933)
(torque/magnetic flux)
32
Setting
Initial
Parameter
Range
Value
0
0 to 5
0 to 10Hz,
6Hz
9999
100%
0 to 200%
0 to 9999
9999
*1
9999
0 to 9999
0 to 4, 9999
9999
100%
30 to 150%
Inverter
0.1 to 55/
*2
rated
0 to 3600kW
*2
capacity
*3
0, 1, 2, 3
0
*4
9999
0, 1, 9999
0 to 500, 9999
9999
*5
0,1 to 1000h,
*6
9999
9999
*7
0, 1, 10, 9999
9999
0 to 100%,
9999
9999
0Hz
0 to 400Hz
0%
0 to 300%
0 to 400Hz
Hz
60
100%
0 to 300%
0 to 400Hz
0Hz
0 to 300%
20%
Hz
0 to 400Hz
60
0 to 300%
100%
0Hz
0 to 400Hz
0%
0 to 300%
Hz
0 to 400Hz
60
100%
0 to 300%
0%
0 to 400%
0%
0 to 300%
150%
0 to 400%
100%
0 to 300%
0%
0 to 400%
0 to 300%
20%
0 to 400%
150%
Name
C41
Terminal 4 gain (torque/
(933)
magnetic flux)
Parameter copy alarm
989
release
990
PU buzzer control
991
PU contrast adjustment
Pr. CL
Parameter clear
ALLC
All parameter clear
Er.CL
Faults history clear
PCPY
Parameter copy
Differ according to capacities.
6%: FR-A720-00030, 00050 (FR-A740-00015, 00025)
5%: FR-A760-00017
4%: FR-A720-00080 to 00175 (FR-A740-00040 to 00090)
3%: FR-A720-00240, 00330(FR-A740-00120, 00170)(FR-A760-00040)
2%: FR-A720-00460 to 02150(FR-A740-00230 to 01100)
(FR-A760-00061, 00120)
1%: FR-A720-02880(FR-A740-01440)(FR-A760-00220) or more
Differ according to capacities. (FR-A720-02150(FR-A740-01100, FR-
A760-00840) or less/FR-A720-02880(FR-A740-01440, FR-A760-01040)
or more)
Differ according to capacities. (FR-A720-00330(FR-A740-00170, FR-
A760-00120) or less/FR-A720-00460(FR-A740-00230, FR-A760-00220)
or more)
Differ according to capacities.
4%: FR-A720-00330 (FR-A740-00170) or less
2%: FR-A720-00460 to 02150 (FR-A740-00230 to 01100)
1%: FR-A720-02880 (FR-A740-01440) or more, FR-A760
Differs according to the voltage class. (200V class, 400V class/600V
class)
Differs according to the voltage class. (200V class/400V class/600V
class)
Setting can be made only when the FR-A7AP is mounted.
Setting
Initial
Range
Value
0 to 300%
100%
10/100
10/100
*2
1
0, 1
0 to 63
58
0, 1
0
0, 1
0
0, 1
0
0
0, 1, 2, 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents