Safety Information
Never ground yourself when taking electrical
measurements. Do not touch exposed metal
pipes, outlets, fixtures, etc., which might be
at ground potential, while taking measure-
ments. Keep your body isolated from ground
by using dry clothing, rubber shoes, rubber
mats, or any approved insulating material.
Disconnect the test leads before opening the
case. Inspect the test leads for damage to the
insulation or exposed wire. Replace if suspect.
Keep your fingers behind the finger guards
on the probes while taking measurements.
When disconnecting from a circuit, disconnect
the "RED" lead first, then the common "BLACK"
lead. Use one handed testing when possible.
Work with others.
Turn off power to the circuit under test before
cutting, unsoldering, or breaking the circuit.
Do not measure resistance (ohms) when circuit
is powered. Isolate load by disconnecting
from circuit.
Disconnect the meter from circuit before turning
any inductor off, including motors, transform-
ers, and solenoids. High voltage transients
can damage the meter beyond repair.
06
Quick Start
1. For electrical testing, connect test leads to
"COM" and "+" jacks.
2. Rotate the dial to your desired measurement.
3. Connect to test points and read measurement.
4. For temperature testing, remove test leads,
slide TEMP switch to the right and connect
Type K thermocouple.
Certifications
UL 61010-1, Third Edition
EN61010-1
EN61010-2-032
EN61010-2-033
EMC EN61326-1
C-Tick (N22675)
WEEE
CATIII 600V, class II and pollution degree 2
indoor use comply with CE, RoHS compliant.
CATIII: Is for measurements performed in the
building installation.
02
Do not use during electrical storms.
Do not apply more than rated voltages between
input and ground.
Isolate capacitors from system and discharge
them safely before testing.
Temperature switch prevents leaving thermo-
couple plugged in while measuring voltage.
When measuring high frequency AC current, do
not exceed the rated 400AAC of the clamp.
Failure to adhere may cause the clamp to heat
up dangerously.
All voltage tests: All voltage ranges will
withstand up to 600V. Do not apply more than
600VDC or AC rms.
Symbols used:
Caution, risk of electric shock
Caution, refer to manual.
!
Ground
Double insulation
WARNINGS
!
DISCONNECT AND UNPLUG TEST LEADS before opening case.
TEST NCV FUNCTION ON KNOWN LIVE WIRE before using.
DO NOT APPLY VOLTAGE greater than 30VAC or 60VDC to the
thermocouple or the jacks when the rotary dial is on °F°C. (Use
only Type K thermocouples)
DO NOT APPLY VOLTAGE TO THE JACKS when the rotary dial is on
microamps. Even low voltages can cause a current overload and
potentially harm the meter.
07
Description
The SC600 series are the new loaded clamp
meters for the HVACR professional. Hang your
SC600 series clamp meter to any metallic surface
with the redesigned heavy-duty magnet and
conveniently store your test leads when the
job is done. See both voltage and amperage
readings at the same time on the big dual LCD
display, even in low light conditions using the
bright blue backlight (backlight SC640 only).
Easily see your amperage readings no matter
how you clamp around a wire with the swivel
head AAC clamp.
Take more accurate VAC and AAC readings on
variable frequency drives with True RMS sensing
NCV
technology (SC640 only). Measure the starting
MFD
amp draw of a compressor with Inrush current
feature (SC640 only). Use the clamp jaw light to
easily light up the test area. (SC640 only).
Take measurements with one hand using the
NCV
Range
single test lead holder for added safety. Test
MFD
leads come with removable gold plated tips to
connect with Fieldpiece accessory heads.
The SC600 series clamp meters are built to
withstand the rigors of HVACR with high impact
plastic and a display you can read in very hot or
Range
TYPE K
very cold environments.
COM
03
Specifications
Display: 5000 count dual display
Backlight: 60 second duration with auto-off. Blue color. SC640 only.
TYPE K
Overrange: (OL) or (-OL) is displayed
COM
Measurement rate: 3.3 times per second, nominal
Zero: Automatic
Operating environment: 32°F to 122°F (0°C to 50°C) at <70%
relative humidity
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH
(with battery removed)
Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
Temperature coefficient: 0.1 x (specified accuracy) per °C [0°C to
19°C (32°F to 66°F), 28°C to 50° C (82°F to 122°F)]
APO (Auto Power Off): Approx. 30 minutes
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life: 200 hours typical alkaline (SC620); 100 hours typical
alkaline (SC640)
Low battery indication: Battery icon blinks and "LO.bt" is displayed
when the battery voltage drops below the operating level
Dimensions: 287.5mm(H) x 79.5mm(W) x 50.0mm(D)
Weight: Approx. 450g including battery
Altitude: Up to 6562 ft (2000m)
Overload protection: 600 VDC or 600VAC rms unless otherwise
stated
Test leads: Use UL listed test leads that comply to UL61010-031
rated CATIII 600V or above. Included test leads are gold-plated
and have removeable safety caps.
Please operate the instrument following all instructions
of the operator's manual to avoid impairing the safety
of the product.
08
O
F
°C
%
F
MFD
°F
Hz
F
MFD
F
%
°C
Hz
°F
%
Hz
°C
°F
Controls
°C
°F
OFF
H
Z
A
50
AC
H
V
Z
AC
A
NCV
400
AC
V
AC
MFD
V
DC
H
Z
%
µA
°F
DC
°C
TRUE RMS
TRUE RMS
OFF
H
Z
50
A
AC
TRUE RMS
TRUE RMS
V
H
Z
AC
30V
NCV
A
30V
400
AC
V
MAX
Rotate dial to the function you want to use.
AC
MAX
TRUE RMS
TRUE RMS
AUTO OFF
MFD
V
30V
30V
TEMP
DC
MAX
MAX
H
Z
%
OFF
H
30V
TEMP
TEMP
Z
A
50
AC
µA
MAX
H
°F
DC
CAT III
V
AC
Z
A
°C
400
AC
TEMP
600V
V
AC
Press to cycle Amps AC and frequency
CAT III
CAT III
V
DC
600V
600V
H
Z
within VAC/AAC/Hz switch position.
%
CAT III
TRUE RMS
OFF
H
Z
600V
µA
°F
DC
50
A
AC
Range
Hold
°C
H
V
AC
Z
TRUE RMS
TRUE RMS
A
NCV
400
AC
30V
SC640
V
AC
MAX
Press to illuminate backlight (SC640).
TRUE RMS
OFF
H
MFD
V
Z
DC
30V
A
TRUE RMS
50
AC
MAX
H
V
Z
AC
H
Z
A
400
AC
%
30V
Hold
V
AC
MAX
TRUE RMS
Press to activate inrush current
°F
µA
30V
DC
SC640
V
DC
MAX
TEMP
°C
INRUSH
capture mode (SC640).
TEMP
H
Z
%
µA
CAT III
°F
DC
AUTO OFF
600V
°C
CAT III
Press to manually select a range.
600V
Range
30V
Hold
TYPE K
MAX
TRUE RMS
COM
SC640
AUTO OFF
Press to freeze the display.
Hold
TRUE RMS
30V
SC640
MAX
04
Functions
AUTO OFF
30V
TYPE K
MAX
Temperature (°F/°C)
COM
AUTO OFF
Plug any Type K thermocouple directly into the meter to measure
30V
MAX
temperature. Cold junction is located inside the meter and allows for
extremely accurate measurements even in rapidly changing ambient
temperatures (going from rooftop to freezer). No adapter is required.
Range: -30°F to 932°F, (-35°C to 500°C) Resolution: 0.1°
Accuracy: ±(1°F)* 32°F to 120°F, ±(1°C) 0°C to 49°C
±(1%+2°F) 32°F to 572°F, ±(1%+1°C) 0°C to 300°C
±(2%+6°F) -30°F to 32°F, ±(2%+3°C) -35°C to 0°C
±(2%+6°F) 572°F to 932°F, ±(2%+3°C) 300°C to 500°C
Sensor type: Type K thermocouple *After field calibration
Overload protection: 30 VDC or 30VAC rms
Non Contact Voltage (NCV)
Use NCV to check 24VAC from a thermostat or live voltage up to
600VAC. Always test a known live source before using. A segment graph
and RED LED will display the presence of voltage. Audible beep increases
from intermittent to continuous as intensity of field (EF) increases.
AC Voltage Detection Range: 24VAC to 600VAC (50-60Hz)
Voltage AC (VAC) (50Hz-500Hz)
Test power lines (120, 220, 480), test 24V going to controls, and
test for transformer failure.
Ranges: 500mV, 5V, 50V, 500V, 600V Resolution: 0.1mV
Accuracy: ±(1.2% + 8) 500mV range (50-60Hz)
±(1.2%+8), 5V, 50V, 500V; ±(1.5% + 8) 600V range
True RMS: model SC640 only Crest factor: ≤ 3
Audio/Visual Hi-V indicator: >30VAC/VDC
Input impedance: >100MΩ (500mV), 10MΩ (5V),
9.1MΩ (50V-600V)
09
Hz
A
SEL
AC
SEL
SEL
INRUSH
V
AC
A
AC
V
NCV
DC
V
V
AC
DC
INRUSH
NCV
Display
SEL
NCV
SEL
INRUSH
SEL
SEL
INRUSH
Battery Life (replace 9V if blinking)
SEL
INRUSH
SEL
Auto Power Off Enabled
High Voltage Warning (>30VAC/VDC)
Manual Range (RNG) Mode
SEL
Data Hold Mode
SEL
Inrush Amps Mode (SC640)
SEL
Continuity Test
SEL
SEL
Diode Test
TRUE RMS
AUTO OFF
TRUE RMS
AUTO OFF
TRUE RMS
AUTO OFF
Frequency Test (hertz)
30V
30V
K-TYPE
MAX
30V
K-TYPE
Resistance Test (ohms)
AUTO OFF
MAX
AUTO OFF
K-TYPE
MAX
TEMP
TEMP
TEMP
Capacitance Test (farads)
AUTO OFF
AUTO OFF
K-TYPE
K-TYPE
Duty Cycle Test (percentage)
CAT III
AUTO OFF
CAT III
CAT III
TEMP
600V
K-TYPE
K-TYPE
600V
Micro Unit (10
600V
, one millionth)
−6
30V
K-TYPE
K-TYPE
MAX
Milli Unit (10
−3
, one thousandth)
CAT III
TEMP
600V
Kilo Unit (10
, one thousand)
3
TRUE RMS
AUTO OFF
CAT III
Mega Unit (10
, one million)
6
AUTO OFF
30V
600V
K-TYPE
MAX
AUTO OFF
TEMP
K-TYPE
AUTO OFF
TEMP
AUTO OFF
K-TYPE
CAT III
TEMP
600V
K-TYPE
CAT III
K-TYPE
600V
CAT III
600V
05
AUTO OFF
OFF
H
Z
A
50
AC
H
V
30V
Z
TYPE K
AC
MAX
A
NCV
400
AC
V
AC
COM
MFD
V
DC
H
Z
%
Unplug Leads and Slide
µA
°F
DC
TEMP Switch to the Right
°C
OFF
H
Z
A
50
AC
H
V
Z
AC
NCV
A
400
AC
V
AC
MFD
V
DC
H
Z
%
µA
°F
DC
°C
10
Need help?
Do you have a question about the SC640 and is the answer not in the manual?
Questions and answers