Fieldpiece
Compact
Clamp
Meters
OPERATOR'S
MANUAL
Models SC260
SC240 SC220
01
Safety Information
Never ground yourself when taking electrical
measurements. Do not touch exposed metal
pipes, outlets, fixtures, etc., which might be
at ground potential, while taking measure-
ments. Keep your body isolated from ground
by using dry clothing, rubber shoes, rubber
mats, or any approved insulating material.
Disconnect the test leads before opening the
case. Inspect the test leads for damage to the
insulation or exposed wire. Replace if suspect.
Keep your fingers behind the finger guards on
the probes while taking measurements.
When disconnecting from a circuit, disconnect
the "RED" lead first, then the common "BLACK"
lead. Use one handed testing when possible.
Work with others.
Turn off power to the circuit under test before
cutting, unsoldering, or breaking the circuit.
Do not measure resistance (ohms) when circuit
is powered. Isolate load by disconnecting
from circuit.
Disconnect the meter from circuit before turning
any inductor off, including motors, transform-
ers, and solenoids. High voltage transients
can damage the meter beyond repair.
06
Quick Start
1. For electrical testing, connect test leads to
"COM" and "+" jacks.
2. Rotate the dial to your desired measurement.
3. Connect to test points and read measurement.
4. For temperature testing, remove test leads,
slide TEMP switch to the right and connect
Type K thermocouple (SC240/SC260 only).
Certifications
UL 61010-1, Third Edition
EN61010-1
EN61010-2-032
EN61010-2-033
EMC EN61326-1
C-Tick (N22675)
WEEE
CATIII 600V, class II and pollution degree 2
indoor use comply with CE, RoHS compliant.
CATIII is for measurements performed in the
building installation.
02
Do not use during electrical storms.
Do not apply more than rated voltages between
input and ground.
Isolate capacitors from system and discharge
them safely before testing.
Temperature switch prevents leaving thermo-
couple plugged in while measuring voltage.
When measuring high frequency AC current, do
not exceed the rated 400AAC of the clamp.
Failure to adhere may cause the clamp to heat
up dangerously.
All voltage tests: All voltage ranges will
withstand up to 600V. Do not apply more than
600VDC or AC rms.
Symbols used:
Caution, risk of electric shock
Caution, refer to manual.
!
Ground
Double insulation
WARNINGS
!
DISCONNECT AND UNPLUG TEST LEADS before opening case.
TEST NCV FUNCTION ON KNOWN LIVE WIRE before using.
DO NOT APPLY VOLTAGE greater than 30VAC or 60VDC to the
thermocouple or the jacks when the rotary dial is on °F°C. (Use
only Type K thermocouples)
DO NOT APPLY VOLTAGE TO THE JACKS when the rotary dial is on
microamps. Even low voltages can cause a current overload and
potentially harm the meter.
07
Hz
Hz
°C
°C
°F
°F
INRUSH
INRUSH
Description
The new SC200 series compact clamp meters
are designed for everyday HVACR service. Their
SEL
compant pocketable design makes them easy
to take on any job.
Hang the SC260 to any metallic surface with
Fieldpiece
SEL
SEL
its newly designed swivel magnet to keep your
hands free to do more. Test variable frequency
MFD
drives more accurately with True RMS and easily
see your measurements in low lighting with the
NCV
bright blue blacklight (SC260 only).
°F°C
Save time with the new Auto Select mode.
Fieldpiece
Simply set the dial to (
/
/
/MFD) and
connect your leads. Your meter will automatically
°F°C
TRUE RMS
AUTO OFF
MFD
select the appropriate measurement depending
30V
K-TYPE
on what it detects. Move from a cold freezer to
MAX
NCV
TEMP
a hot rooftop and get accurate temperature
°F°C
TRUE RMS
TRUE RMS
AUTO OFF
AUTO OFF
measurements that lesser thermometers cannot
CAT III
30V
30V
600V
K-TYPE
K-TYPE
measure properly (SC240/SC260 only).
MAX
MAX
SC260
TEMP
TEMP
Test for proper flame rectification micro amp
DC current on heating systems (SC220 only).
CAT III
CAT III
600V
600V
All SC200 compact clamp meters are built to
withstand the rigors of HVACR service with high
impact plastic and a display you can read in very
hot or very cold environments.
SC240
AUTO OFF
03
TYPE K
COM
Specifications
TYPE K
CAT III
Display: 4000 count
600V
AUTO OFF
Backlight: 5 minute duration with auto-off. Blue color. SC260 only
Overrange: (OL) or (-OL) is displayed
TYPE K
Measurement rate: 3 times per second, nominal
COM
Zero: Automatic
Operating environment: 32°F to 122°F (0°C to 50°C) at <70%
relative humidity
CAT III
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH
600V
(with battery removed)
Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
Temperature coefficient: 0.1 x (specified accuracy) per °C [0°C to
19°C (32°F to 66°F), 28°C to 50° C(82°F to 122°F)]
APO (Auto Power Off): Approx. 30 minutes
Power: 9V, NEDA 1604A, IEC 6LR61 9V alkaline battery
Battery life: 200 hours typical alkaline (SC220/SC240); 150 hours
typical alkaline (SC260)
Low battery indication: Battery icon blinks and "LO.bt" is displayed
when the battery voltage drops below the operating level
Dimensions: 205.5mm(H) x 67.4mm(W) x 45.1mm(D)
Weight: Approx. 265g including battery
Altitude: Up to 6562 ft (2000m)
Overload protection: 600 VDC or 600VAC rms unless otherwise
stated
Test leads: Use UL listed test leads that comply to UL61010-031
rated CATIII 600V or above. Included test leads are gold-plated
and have removeable safety caps.
Please operate the instrument following all instructions
of the operator's manual to avoid impairing the safety
of the product.
08
O
%
Hz
MFD
F
°C
%
MFD
°F
Hz
F
°C
%
°F
Controls
Hz
°C
°F
MFD
Fieldpiece
A
AC
NCV
V
TRUE RMS
AC
V
°F°C
DC
MFD
A
AC
TRUE RMS
NCV
V
AC
°F°C
V
DC
Fieldpiece
A
AC
V
TRUE RMS
AC
V
DC
MFD
A
AC
Rotate dial to the function you want to use.
NCV
V
TRUE RMS
AC
V
DC
TRUE RMS
TRUE RMS
30V
MAX
Select a parameter. Ohms/Continuity/
TRUE RMS
AUTO OFF
TEMP
30V
A
AC
MAX
Diode/MFD. °F/°C (SC240/260 only).
V
30V
TEMP
AC
SC260
MAX
CAT III
V
DC
TEMP
Toggle backlight (SC260 only).
CAT III
TRUE RMS
600V
CAT III
TRUE RMS
30V
600V
MAX
Freeze maximum and minimum read-
TRUE RMS
30V
MAX
ing. Hold for 1 second to clear .
30V
(SC240/SC260 only)
MAX
SC260
TEMP
AUTO OFF
Manually select a range (SC220/240).
CAT III
600V
30V
TYPE K
MAX
TEMP
Freeze the display.
HOLD
COM
30V
04
MAX
TEMP
CAT III
AUTO OFF
600V
Functions
30V
MAX
TEMP
Temperature (°F/°C)
COM
SC240 and SC260 only
Plug any Type K thermocouple directly into the meter to measure
30V
temperature. Cold junction is located inside the meter and allows for
MAX
TEMP
CAT III
extremely accurate measurements even in rapidly changing ambient
600V
temperatures (going from rooftop to freezer). No adapter is required.
See Temp Calibration section for calibration instructions.
Range: -30°F to 752°F, (-35°C to 400°C) Resolution: 0.1°
Accuracy: ±(1°F)* 32°F to 120°F, ±(1°C) 0°C to 49°C
±(1%+2°F) 32°F to 392°F, ±(1%+1°C) 0°C to 200°C
±(2%+6°F) -30°F to 32°F, ±(2%+3°C) -35°C to 0°C
±(2%+6°F) 392°F to 752°F, ±(2%+3°C) 200°C to 400°C
Sensor type: Type K thermocouple *After field calibration
Overload protection: 30 VDC or 30VAC rms
Voltage DC (VDC)
Select VDC and measure DC voltages on circuit boards on more
advanced HVACR systems.
Ranges: 4V, 40V, 400V, 600V Resolution: 0.001V
Accuracy: ±(0.5% + 2)
Input impedance: 10MΩ (4V), 9.1MΩ (40V-600V)
Voltage AC (VAC) (50Hz-500Hz)
Test power lines (120, 220, 480), test 24V going to controls, and
test for transformer failure.
Ranges: 4V, 40V, 400V, 600V Resolution: 0.001V
Accuracy: ±(1.2% + 8)
±(1.5% + 8) on 600V range
True RMS: model SC260 only Crest factor: ≤ 3
Audio/Visual Hi-V indicator: >16VAC/35VDC
Input impedance: 10MΩ (4V), 9.1MΩ (40V-600V)
09
HOLD
SEL
F
A
SEL
AC
°C
SEL
Hz
°F
F
V
NCV
V
AC
DC
SEL
A
AC
INRUSH
NCV
V
V
Display
AC
DC
INRUSH
NCV
INRUSH
Battery Life (replace 9V if blinking)
SEL
SEL
SEL
INRUSH
Auto Power Off Enabled
SEL
SEL
High Voltage Warning (>16VAC/35VDC)
SEL
Manual Range (Range) Mode
Maximum Reading
SEL
Minimum Reading
SEL
Data Hold Mode
SEL
Auto Select Mode (
/
/
/MFD)
TRUE RMS
AUTO OFF
TRUE RMS
SEL
AUTO OFF
TRUE RMS
AUTO OFF
Continuity Test
TRUE RMS
AUTO OFF
30V
30V
K-TYPE
MAX
30V
K-TYPE
Diode Test
MAX
K-TYPE
MAX
TEMP
30V
TEMP
K-TYPE
TEMP
Resistance Test (ohms)
MAX
TEMP
Capacitance Test (farads)
CAT III
AUTO OFF
CAT III
TRUE RMS
TRUE RMS
AUTO OFF
AUTO OFF
CAT III
600V
600V
Nano Unit (10
600V
, one billionth)
CAT III
-9
AUTO OFF
AUTO OFF
30V
30V
600V
K-TYPE
K-TYPE
K-TYPE
Micro Unit (10
−6
, one millionth)
MAX
MAX
30V
TEMP
TEMP
K-TYPE
K-TYPE
MAX
Milli Unit (10
, one thousandth)
−3
TEMP
K-TYPE
Kilo Unit (10
, one thousand)
3
TRUE RMS
AUTO OFF
CAT III
CAT III
600V
600V
600V
Mega Unit (10
, one million)
CAT III
6
AUTO OFF
30V
600V
K-TYPE
MAX
AUTO OFF
TEMP
K-TYPE
AUTO OFF
TEMP
K-TYPE
CAT III
TEMP
600V
K-TYPE
CAT III
600V
CAT III
600V
05
AUTO OFF
MFD
30V
A
AC
TYPE K
MAX
NCV
V
AC
COM
°F°C
V
DC
Unplug Leads and Slide
TEMP Switch to the Right
MFD
A
AC
NCV
V
AC
V
°F°C
DC
MFD
A
AC
NCV
V
AC
V
°F°C
DC
10
Need help?
Do you have a question about the SC260 and is the answer not in the manual?
Questions and answers