Alarms and faults
Table of faults and alarms
A: Alarm
N°
A/F
04
A
Supply valves IC
05
A
Change M6'
07
F
Recuperation sensor out of service
08
F
HV supply overload
09
F
Piezo supply overload
10
A
External communication timeout
11
F
Pressure leak blocked
12
F
Invalid data
13
F
Not configured printer
14
F
Incorrect external data received
15
F
Ink pump
17
F
Insufficient pressure
18
F
Font used in message not available
20
F
Recup. Valve Default
21
A
Duplicate print non autorised
22
F
Pressure pump
23
F
Ink curve unselected
24
F
Head Make-up Valve Default
26
F
Pressure Valve Default
27
A
Refresh Valve Default
29
F
Ink Valve Default
30
F
Memory lost
32
F
Incorrect date / time composition
35
F
Cooling fan failure
40*
A
Print speed above specifications
42
A
Ink cartridge invalid
45
A
Additive cartridge invalid
46
F
Ink and additive incorrect
48*
F
Algorithm not available
49
D
Make-up pump
50*
A
LOW INK level. Prep. new cartridge
51*
A
LOW make-up. Prepare new cartridge
52*
A
EMPTY INK Cartridge
53*
A
EMPTY make-up Cartridge
54*
F
Full waste cartridge
55
A
Prevent : Change air filters
61*
F
Recuperation pump
65
F
Invalid M6'
68
F
Life of the M6' exceeded
69
A
PRINTER STOP NOT PROPERLY
70*
A
Ink concentration out of specif.
F: Fault
Message displayed
Recommendation
Call Markem-Imaje service**
Replace M6'
Call Markem-Imaje service**
Check cleanliness head
Check cleanliness head
Check connection with extern device
Call Markem-Imaje service**
Check message
Configure the printer
Check identifiers/checksum of data
Maint: Clean Ink Pump
Drain printer
Check fonts in relation with message
Call Markem-Imaje service**
Check timings send data/print signal
Call Markem-Imaje service**
Select an ink curve
Call Markem-Imaje service**
Maint: Pressure valve cleaning
Check valve in maint menu
Maint: Clean Ink Pump
Call Markem-Imaje service**
Check data send or Hijri entry
Check fan rotation
Adjust encoder div. / use other Algo
Check the reference of ink
Check the reference of additive
Check reference of ink and additive
Check Algorithm used in send message
Check the position of the cartridge in the cartridge
holder. If the fault persists, contact Markem-Imaje
service**
Wait EMPTY alarm before replacing
Wait EMPTY alarm before replacing
Replace ink cartridge
Replace make-up cartridge
Replace waste cartridge
Preventive change air filters
Maint: Clean recup pump
Call Markem-Imaje service**
Call Markem-Imaje service**
PLEASE ALWAYS USE ON/OFF TO STOP
Drain printer
150/176
A46980-AB.doc