Cable Configurations

The LFH200 cable is available in three configurations:
SH200LFH-4xDB50F-C
SH200LFH-4xDB50F-S
SH200LFH-BARE WIRE
The following sections describe each of the LFH200 cable configurations.

SH200LFH-4xDB50F-C Cable

The SH200LFH-4xDB50F-C cable is recommended for connecting the PXI-2569/2570/2571 or
SCXI-1169 to your system. One end of the cable terminates with an LFH200 connector which
connects to the switch module. The other end of the cable terminates with four 50-pin female
D-SUB connectors.
When using the SH200LFH-4xDB50F-C cable with the PXI-2569 or SCXI-1169, each Channel
and its corresponding Common form a twisted pair. For example, CH0 is paired with COM0,
and CH1 is paired with COM1. Figure 5 illustrates how this pairing relates to the pins on the
PXI-2569 or SCXI-1169.
CH0
CH2
CH4
CH6
CH8
Figure 5. Twisted Pair Groupings for the PXI-2569 or SCXI-1169
When using the SH200LFH-4xDB50F-C cable with the PXI-2570, each Channel and its
corresponding NO (Normally Open) connection form a twisted pair. The NC (Normally Closed)
connection is twisted with NO CONNECT wires. For example, COM0 is twisted with NO0, and
NC0 is twisted with a NO CONNECT wire. Figure 6 illustrates how this pairing relates to the
pins on the PXI-2570.
© National Instruments Corporation
150
COM0
151
149
COM2
152
148
COM4
153
147
COM6
154
146
COM8
155
51
CH1
50
52
CH3
49
53
CH5
48
54
CH7
47
55
CH9
46