List Of The Emc Directive Compliant Filters And Their Applicable Inverters - Mitsubishi Electric FR-A701 Installation Manuallines

Emc
Hide thumbs Also See for FR-A701:
Table of Contents

Advertisement

4.3 List of the EMC Directive compliant filters and their applicable inverters

●FR-A701 series
EMC filter
Applicable inverter
model name
model name
SF1174B
FR-A741-5.5K, 7.5K
SF1175
FR-A741-11K, 15K
SF1176
FR-A741-18.5K, 22K
SF1177
FR-A741-30K
SF1178
FR-A741-37K, 45K
SF1179
FR-A741-55K
* The leakage current indicated is equivalent to one-phase of cable for the three-phase three-wire star connection. For
a three-phase, three-wire, delta-connection power supply, the value is about three times greater than the indicated.
(Note) Outline dimension drawing shown is one of a typical model. The shape differs according to each model.
●FR-E700 series
EMC filter
Applicable inverter
model name
model name
SF1306
FR-E720-0.1K to 1.5K
FR-E720-2.2K, 3.7K
SF1309
FR-E720S-2.2K
SF1320
FR-E720S-0.1K to 0.4K
SF1321
FR-E720S-0.75K
FR-E5NF-H0.75K
FR-E740-0.4K, 0.75K
FR-E5NF-H3.7K
FR-E740-1.5K to 3.7K
FR-E5NF-H7.5K
FR-E740-5.5K, 7.5K
FR-S5NFSA-1.5K
FR-E720S-1.5K
EMC filter
Applicable inverter
model name
model name
FR-E720-5.5K, 7.5K
SF1260
FR-E720-11K
SF1261
FR-E720-15K
SF1175
FR-E740-11K, 15K
*1 When the intercompatibility attachment is mounted, the depth will increase by 12mm.
*2 The leakage current indicated is equivalent to one-phase of cable for the three-phase three-wire star connection. For
a three-phase, three-wire, delta-connection power supply, the value is about three times greater than the indicated.
(Note) Outline dimension drawing shown is one of a typical model. The shape differs according to each model.
Outline
dimension
Mass
(Unit: mm)
(kg)
W
H
D D1
213 360 38
-
1.8
253 530 60 25
4.7
303 600 60 29
5.9
327 700 80 29
9.4
450 770 80 36
16
467 920 80 36
19
Outline
dimension
Intercompatibility
(Unit: mm)
attachment*1
W
H
-
110
200
FR-E5T
200
282
FR-E7AT03
-
70
168
-
110
168
-
140
210
-
140
210
-
220
210
-
110
168
Outline
dimension
Intercompatibility
(Unit: mm)
attachment*1
W
H D D1
FR-E5T-02
222 468 80
FR-A5AT03
FR-AAT02
253 600 86 28.5
FR-AAT02
253 530 60
4 - 7
Leakage
current
(mA) *
(reference
value)
51
76
108
156
W
156
156
Leakage
current
Mass
(mA) *2
Loss
(kg)
(W)
(reference
D
value)
36.5
0.7
10
7.3
57
2.1
15
15
30.5
0.4
10
2.7
36.5
0.6
10
3.8
46
1.1
22.6
5.5
46
1.2
44.5
8
47
2
68.4
15
35
0.7
9.5
8.55
Leakage
current
Loss
Mass
(mA) *2
(W)
(kg)
(reference
value)
29
5
440
118
9.3
71
37
25
4.7
76
56
D
D
D1
D
W
D1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-f700Fr-a700Fr-e700Fr-d700

Table of Contents