Problem
Salty tasting or
brown/yellow colored
water after installation
Brown/yellow
colored water
Sounds you might hear
during regeneration
cycle
Water has air bubbles
and is cloudy
Possible Causes
Unit not sanitized
Low water pressure
Restricted drain hose
Unit was idle for a period of time
Running water from the unit
into a drain during regeneration
Harmonic noises during regeneration
Clicking
Air in system after installation
What To Do
• Complete the Sanitizing Procedures on page 15.
• At completion of regeneration cycle (approx. 2 hrs), run water
from faucets to purge the salty water.
Check pressure.
• Drain height 8' or less, pressure should be minimum of 20 psi.
• Drain height above 8', pressure should be minimum of 50 psi.
• Clean and reconnect drain line.
• Check for kinks in drain line.
• Complete the Sanitizing Procedures on page 15.
• This is normal. High water flows in backwash cycle, flushes
minerals and sediments from resin tank.
• This is normal.
• This is normal. This is the sound of various valves opening and
closing as valves cycle through regeneration cycle.
• Will go away after it runs for a while.