Advertisement

TMB-986 英文说明书 (A0 )
印色:单黑
材质:80G书纸
尺寸:170*120mm
GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD
Address: Zone A, No.105 ,Dongli Road, Torch Development District,
Zhongshan,528437,Guangdong,China
EC REP
User Manual
Blood Pressure Monitor
Thank you very much for purchasing TRANSTEK Blood Pressure Monitor
TMB-986.
Please do read the user manual carefully and thoroughly so as to ensure
the safe usage of this product and keep the manual well for further refer-
ence in case you have problems.
Version:1.0
TMB-986
Arm Type

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMB-986 and is the answer not in the manual?

Questions and answers

Summary of Contents for TRANSTEK TMB-986

  • Page 1 User Manual Blood Pressure Monitor TMB-986 Arm Type Thank you very much for purchasing TRANSTEK Blood Pressure Monitor TMB-986. GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD Please do read the user manual carefully and thoroughly so as to ensure Address: Zone A, No.105 ,Dongli Road, Torch Development District,...
  • Page 2: Table Of Contents

    CATALOGUE CATALOGUE Table of Contents INTRODUCTION ..........................2 General Description Safety Information LCD Display Signal Monitor Components BEFORE YOU START........................6 Installing and Replacing the Batteries Setting Date and Time MEASUREMENT..........................10 Tie the Cuff Start the Measurement DATA MANAGEMENT........................12 Recall the Records Delete the Records INFORMATION FOR USER ......................14 Tips for measurement...
  • Page 3: Introduction

    It is not intended for use on extremities other than the arm or for functions other than obtaining a blood pressure measurement. Reading taken by the TMB-986 are equivalent to those obtained by a trained Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood observer using the cuff and stethoscope auscultation method.
  • Page 4: Lcd Display Signal

    The erecords will be showed Irregular heartbeat Irregular heartbeat 1.Blood Pressure Monitor 2. Cuff (22~42cm) 3. 4 x AAA Batteries (TMB-986) (Type BF Applied Part) User A The User A is chosen User B The User B is chosen Grade...
  • Page 5: Before You Start

    BEFORE YOU START BEFORE YOU START Installing and Replacing the Batteries Setting Date and Time It is important to set the clock before using your blood pressure Battery powered mode: 6VDC 4*AAA batteries monitor, so that a time stamp can be assigned to each record that 1.Slide off the battery cover.
  • Page 6 BEFORE YOU START BEFORE YOU START 6. After confirming the minute,the 4.Repeat step 2 and 3 to set the [MONTH] and [DAY]. LCD will display “dOnE” and the monitor will shut off. START START STOP STOP START START STOP STOP 5.Repeat step 2 and 3 to set the [HOUR] and [MINUTE].
  • Page 7: Measurement

    MEASUREMENT MEASUREMENT Tie the Cuff Start the Measurement START 1.When the monitor is off, select User A 1.Tie the cuff on your upper arm, STOP or User B, press the to turn on the position the tube off-center START STOP toward the inner side of arm in the monitor, and it will finish the whole line with the little finger.
  • Page 8: Data Management

    DATA MANAGEMENT DATA MANAGEMENT Recall the Records Delete the Records 1. Please choose the user A or user B when If you did not get the correct measurement, you can delete all the blood pressure monitor turns off, and results by following below steps. press the “MEM”...
  • Page 9: Information For User

    INFORMATION FOR USER INFORMATION FOR USER Tips for Measurement Maintenance In order to get the best performance, please follow the below It can cause inaccuracy if the measurement is taken in the following instructions. circumstances. Avoid touching water, Put in a dry place and avoid the sunshine clean it with a dry cloth in case.
  • Page 10: About Blood Pressure

    ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure? When ventricles contract and pump blood out Systolic Diastolic Why does my blood of the heart, the blood pressure reaches its blood entering blood discharging maximum value in the cycle, which is called vein artery pressure fluctuate...
  • Page 11: Troubleshooting

    TROUBLESHOOTING SPECIFICATIONS This section includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure monitor. If the products not operating as you think it should, check here before arranging for servicing. Battery powered mode: Power supply 4*AAA batteries,6V...
  • Page 12: Contact Information

    EMC GUIDANCE EMC Guidance Contact Information For more information about our products, please visit www.transtek.cn.you can get customer service, usual problems and customer download, transtek will serve you anytime. Manufactured by: GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD 1) * This product needs special precautions regarding EMC and needs to be Company: GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD...
  • Page 13: Emc Guidance

    EMC GUIDANCE EMC GUIDANCE Table 4 Guidance and MANUFACTURER’s declaration – electromagnetic IMMUNITY – Table 2 Guidance and MANUFACTURER’s declaration – electromagnetic for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING IMMUNITY – for all ME EQUIPMENT and ME SYSTEMS Guidance and manufacturer’s declaration –...
  • Page 14 EMC GUIDANCE EMC GUIDANCE Table 6 Recommended separation distances between portable and mobile RF communications equipment and the ME EQUIPMENT or ME SYSTEM – for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING Recommended separation distances between portable and mobile RF communications equipment and the device. The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.

Table of Contents