Download Print this page

ABB 2CSYD0201B Installation Manual page 12

Outdoor dual ir detector
Hide thumbs Also See for 2CSYD0201B:

Advertisement

4 MAINTENANCE
4.1
Cleaning
To clean the device externally, use a slightly wet cloth.
Regularly check that the front lens is clean and that there are no obstacles.
4.2
Test
Execute the detector test at least once a year. For the test procedure, please refer to
the manual related to the intrusion alarm system of the control unit.
4.3
Battery replacement
The battery in the detector shall not be disposed as urban waste (Directive,
2006/66/EC), as it is subject to separate waste collection in order to avoid
environmental damages.
Battery shall be replaced by qualified personnel.
To replace the battery:
1)
Put the control unit into maintenance status (please refer to the control unit
installation manual).
2)
Disassemble the detector (please refer to the installation steps).
3)
Remove the exhausted battery and insert the new one.
4)
Assemble the detector again.
5)
Execute the detector test to be sure that it works.
6)
Exit the maintenance status if required.
4.4
Device reset
To delete the acquisition address and to restore the factory configuration of the
sensor, press the tamper for 5 times with an interval of at least one second between
each single pressing. The activity must be completed within 16 seconds.
The reset shall be carried out if you want that the device is acquired by another
control unit. To re-acquire the device on the same control unit, it is not necessary to
previously execute the reset procedure.
12
2CSYD0201B

Advertisement

loading