GE D30 series Instruction Manual page 476

Line distance protection system. ur series
Hide thumbs Also See for D30 series:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 18 of 60)
ADDR
REGISTER NAME
40E2
IEC 60870-5-104 protocol common address of ASDU
40E3
IEC 60870-5-104 protocol cyclic data transmit period
40E4
IEC 60870-5-104 current default threshold
40E6
IEC 60870-5-104 voltage default threshold
40E8
IEC 60870-5-104 power default threshold
40EA
IEC 60870-5-104 energy default threshold
40EC
IEC 60870-5-104 power default threshold
40EE
IEC 60870-5-104 other default threshold
40F0
IEC 60870-5-104 client address (5 items)
4104
IEC 60870-5-104 redundancy port
B
4105
Port 2 IP Address
4107
Port 2 IP Subnet Mask
4109
Port 2 Gateway IP Address
410B
PRT2 Ethernet Operation Mode
410C
PRT2 Redundancy Enabled
410D
Port 3 IP Address
410F
Port 3 IP Subnet Mask
4111
Port 3 Gateway IP Address
4113
Port 3 Ethernet Operation Mode
4114
PRT1 GOOSE Enabled
4115
PRT2 GOOSE Enabled
4116
PRT3 GOOSE Enabled
4117
IEC Communications Reserved (39 items)
413E
High Enet Traffic Function
413F
High Enet Traffic Events
4140
DNP object 1 default variation
4141
DNP object 2 default variation
4142
DNP object 20 default variation
4143
DNP object 21 default variation
4144
DNP object 22 default variation
4145
DNP object 23 default variation
4146
DNP object 30 default variation
4147
DNP object 32 default variation
Communications Actuals (Read Only)
4160
Modbus Available TCP/IP Connections
4161
DNP Available TCP/IP Connections
4162
IEC Available TCP/IP Connections
4163
MMS Available TCP/IP Connections
4164
PMU Available TCP/IP Connections
Simple Network Time Protocol (Read/Write Setting)
4168
Simple Network Time Protocol (SNTP) function
4169
Simple Network Time Protocol (SNTP) server IP address
416B
Simple Network Time Protocol (SNTP) UDP port number
Clock (Read/Write Setting)
419F
Synchronizing Source
Clock (Read/Write Command)
41A0
Real Time Clock Set Time
Clock (Read/Write Setting)
41A2
SR Date Format
41A4
SR Time Format
41A6
IRIG-B Signal Type
41A7
Clock Events Enable / Disable
41A8
Time Zone Offset from UTC
41A9
Daylight Savings Time (DST) Function
B-26
RANGE
0 to 65535
1 to 65535
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to1
0 to 100000000
0 to 4294967295
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
1 to 2
1 to 3
0 to 3
0 to 3
0 to 3
0 to 3
1 to 5
0 to 5
0 to 4
0 to 2
0 to 2
0 to 5
0 to 4
0 to 1
0 to 4294967295
1 to 65535
0 to 3
0 to 235959
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
–24 to 24
0 to 1
D30 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
s
1
F001
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
0.01
F001
---
1
F003
---
1
F003
---
1
F126
---
1
F003
---
1
F003
---
1
F003
---
1
F192
1 (Full-Duplex)
---
1
F126
---
1
F003
---
1
F003
---
1
F003
---
1
F192
1 (Full-Duplex)
---
1
F102
---
1
F102
---
1
F102
---
1
F001
---
1
F102
---
1
F102
---
1
F001
---
1
F001
---
1
F523
---
1
F524
---
1
F523
---
1
F523
---
1
F001
---
1
F525
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F003
---
1
F001
---
1
F623
---
1
F050
---
1
F051
---
1
F052
---
1
F114
---
1
F102
hours
0.5
F002
---
1
F102
DEFAULT
0
60
30000
30000
30000
30000
100
30000
0
0 (No)
56554706
4294966272
56554497
0 (No)
56554706
4294966272
56554497
1 (Enabled)
1 (Enabled)
1 (Enabled)
0
0 (Disabled)
0 (Disabled)
2
2
0 (1)
0 (1)
0 (1)
0 (1)
1
0 (1)
4
2
2
5
4
0 (Disabled)
0
123
0 (none)
0
0
0
0 (None)
0 (Disabled)
0
0 (Disabled)
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents