Operation
9
Status and error messages
9.4.3
Status messages
Code
8.8.8.
S2:
Flashing
green
S3:
Off
A1.0
A1.1
A1.2
A1.3
A1.4
A1.5
A1.6
A1.7
A1.8
A1.9
A1.A
A1.c
A1.D
A1.E
A1.F
A1.U
Flashing dot
170
Operating Instructions – MOVIPRO
If you use a parameterizable device, the following status messages are possible.
Meaning
DC 24 V operation, frequency
inverter not ready
Controller inhibit active
No enable
Standstill current
Enable
n-control
M-control
Position hold control
Factory setting
Limit switch reached
Technology option
plus®
IPOS
reference travel
Flying start
Calibrate encoder
Fault display (→ 2 177)
"Safe torque off" active
WARNING!
Risk of injury due to incor-
rectly interpreted display U =
"Safe Torque Off" active –
Severe or fatal injuries. The
display U = "Safe Torque
Off" active is not safety-re-
lated. Thus it must not be
used safety-related.
Application module of the
"PFA-..." power section is
running.
®
ADC
Possible cause
Application module not run-
ning/not loaded
Measure
Create a configuration with
the Application Configurator
and load it into the device.
Need help?