For More Precise Control
High starting torque,
Powerful drive and easy setting
High starting torque
Improved sensorless vector control and auto tuning
produce high starting torque of 200% or more at 0.3Hz.*
Easy setup of motor constants
Ideal for applications which need high torque, such as
cranes, extruders and lifts.
200
0.3Hz
100
0
-100
-200
*1 Starting torque
Series
Applicable motor
SJ700D(CT)
SJ700
185 to 400kW
SJ700B
Possible with SJ700 series
Hitachi exclusive
0Hz domain sensorless
vector control
Develops 150% (SJ700B:120%) *
0Hz speed reference
Ideal for cranes and other applications
that require high torque upon starting.
2
*
when inverter is one frame size larger than motor.
Position control function
The SJ700D/SJ700/SJ700B, with optional feedback board
installed, together with an encoder-equipped motor can
perform position control.
For many applications, suitable performance can be
achieved at a lower cost than servo systems.
Based on your four motion parameters (position command,
speed command, acceleration time and deceleration time),
the SJ700D/SJ700/SJ700B will move an object from original
position A to target position B.
After the movement,
the inverter keeps
hold motor position.
) Derating is applied for SJ700B. Please consult technician at Hitachi or its distributor before use.
*
3
J
700
Motor Torque vs. Speed
300
600
900
1200
1500
1800
Speed (min
-1
)
Starting torque
0.4 to 55kW
0.3Hz/200%
75 to 132kW
0.3Hz/180%
0.3Hz/150%
11 to 75kW
0.5Hz/150%
90 to 160kW
0.5Hz/120%
)
*
2
torque at
Starting point A
Target point B
S
J
700B
For General Purpose Use
Trip avoidance function
Over current &
voltage suppress function
1
Higher internal calculation speed improves current control
performance.
Over-current suppress and Over-voltage suppress functions
avoid inverter trips during acceleration and deceleration.
Frequency
Motor current
Over-current suppress OFF
Impact load
Suppresses over current and continues running
Over-current suppress ON
DC bus AVR function
during deceleration
)
*
The SJ700D/SJ700/SJ700B controls deceleration time so that
the DC bus voltage does not exceed the over-voltage trip
level, providing trip-less operation during deceleration.
Motor current
Output frequency
Over-current trip
Voltage of the
main circuit DC