Field setting mode
Field Setting Value (FSV) Table
Code 4 0∗∗ : User's options for heating devices including internal backup heater and external boiler
401∗ : Space/DHW heating priority and control variables
402∗ : Backup/Booster heater priority and control variables
403∗ : Additional backup boiler operating variables
Code 5 0∗∗ : User's options for extra functions
501∗ : New target temperatures of each mode by "Outgoing" hot key of remote controller
5021 : Temperature difference between before & after values in "Economic" DHW mode
503∗ : TDM(time division multi) variables (TDM product Only)
504∗ : Power Peak control for Smart Grid
Main Menu &
Sub Menu
Code
Function
Heat Pump
Backup Heater
Heating Code
Backup Boiler
40∗∗
Mixing valve
Inverter Pump
Others Code
Outing
50∗∗
40
40
English
English
Field Setting Value
Description
Heating/DHW Priority
Outdoor Temp for Priority ∗∗12
Heating Off
Application
BUH/BSH Priority
∗∗22 0 (Both)
Cold weather
∗∗23
compensation
Threshold Temp
∗∗24
Defrost Backup Temp.
∗∗25
Application
Boiler Priority
∗∗32
Threshold Temp
∗∗33
Application
Target ΔT(Heating)
∗∗42
Target ΔT(Cooling)
∗∗43
Control factor
∗∗44
Control interval
∗∗45
Running Time
∗∗46
Application
Target ΔT
∗∗52
Control factor
∗∗53
Water Out Temp for
Cooling
Room Temp for Cooling
Water Out Temp for
Heating
Room Temp for Heating
Sub
Default
Min
Code
∗∗11 0 (DHW)
0
0
-15
∗∗13
35
14
∗∗21
0 (No)
0
0
1 (Yes)
0 (No)
0
-15
15
10
∗∗31
0 (No)
0
0 (No)
0
-15
-20
∗∗41
0 (No)
0
10
5
10
5
2
1
2
1
9
6
∗∗51
1 (Yes)
0
5
2
2
1
∗∗11
25
5
∗∗12
30
18
∗∗13
15
15
∗∗14
16
16
Max
Step
Unit
1 (Heating)
-
-
20
1
˚C
35
1
˚C
1 (Yes)
-
-
2 (BSH)
1
-
1
-
-
35
1
˚C
55
5
˚C
1 (Yes)
-
-
1 (Yes)
-
-
5
1
˚C
2
1
-
15
1
˚C
15
1
˚C
5
1
-
30
1
min
24
3
(x10) sec
1 (Yes)
-
-
8
1
˚C
3
1
-
25
1
˚C
30
1
˚C
55
1
˚C
30
1
˚C