Module Terminations
A junction box as a terminal enclosure is equipped for
electrical connections on SANYO modules. Modules are
TM
equipped with MC
plugs as a terminal enclosure. Use
these MC
TM
plugs for electrical connections.
Please contact your SANYO authorized representative with
questions
regarding
other
modules.
Junction Box and Terminals
Modules equipped with one junction box contain terminals
for both positive and negative polarity, and bypass diodes.
One terminal is dedicated to each polarity (with the polarity
symbols engraved onto the body of the junction box ) (see
Figure 4).
Conduit
For applications where wire conduits are used, follow the
applicable codes for outdoor installation of wires in conduits.
Verify that all fittings are properly installed to protect wires
against damage and prevent moisture intrusion.
Dimensions
HIP-186BA3, HIP-180BA3, HIP-175BA3
Mount Locations (4 places)
Side
Figure 3.1 Standard Model
Dimensions
electrical
connections
Ground (1 place)

Junction Box

Label
positive ( + )
negative ( - )
63cm (24.8in)
78cm (30.7in)
TM
Connector (MC
Plug)
Backside
Section A-A'
DIODES
Bypass Diodes
When the modules in series strings are shaded partially,
it may cause reverse voltage across cells or modules,
because the current from other cells in the same series
for
is forced to flow through the shaded area. This may
cause undesirable heating to occur. The use of a diode
to bypass the shaded area can minimize both heating
and array current reduction.
All SANYO modules are equipped with factory installed
bypass diodes. The factory installed diodes provide
proper circuit protection for the systems within the
specified system voltage, so that you do not need any
other additional bypass diodes. Contact your authorized
SANYO representative for proper diode type, if it is
necessary to add or change diodes due to system
specifications.