Toshiba TOSVERT VF-AS3 Instruction Manual page 96

High-performance industrial inverter for 3-phase motors, 3-phase 240v class 0.4 to 55kw, 3-phase 480v class 0.4 to 280kw
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

4
Remove four screws of the top cover (mesh) of the DC
reactor.
Store the removed screws so as not to be lost.
5
Remove the top cover (mesh) from the DC reactor.
2
6
Check the positions of four mounting holes on the back side
of the DC reactor and mount the DC reactor to the panel.
7
Wire the DC reactor and the terminals [PA/+] and [PO] of the
power terminal block.
Connect two wires (with a crimp-style terminal) from each of
two DC reactor units to [PA/+] and [PO].
Connect two flat braided wires for grounding to the ground-
9
ing terminals respectively.
8
Mount the top cover (mesh) to the DC reactor and tighten
four screws.
2. Installation and wiring
2-62
E6582062
Top cover
Screw
DC reactor
mounting
holes
PO PA/+
Earth wire
Top cover
Screw