Page 1
*23697287* M490G 23697287 Electromagnetic Locks Installation Instructions Swinging Application Sliding Application For swinging application, go to page 3. For sliding application, go to page 5. Post Gate Gate Post Features Warnings and Cautions Magnetic Bond Sensor (MBS) WARNING Detects proper bond between magnet and armature. It can be monitored remotely.
Page 2
Rehanding Instructions Remove housing screws. Remove the bolts from both endcaps, flip 180° and reinsert into bottom of endcaps. NOTE: Be careful to not pinch any cables in the bottom endcap with the screw! Slide out top endcap. Slide the magnet and bottom endcap into the housing.
Page 3
Swinging Lock Installation Place template and mark holes. Install magnet assembly to non-moving post. a. Place template on gate and post surfaces as marked on 2a Attach L-Bracket to gate. template. b. Mark holes and prepare them per template. Actual Size (4x) 2b Attach mounting bracket to L-Bracket.
Page 4
Install armature to moving part of gate. 3a Attach TJ bracket to gate. 3d Attach armature plate to armature holder. Flat Washer Star Locking Washer Cone Washer Armature Bolt * Actual Size Armature TJ Bracket Plate Actual Size (4x) * Armature bolt must be tightened to 120 in-lbs. Replace with bolt in Gate kit.
Page 5
Sliding Lock Installation Place template and mark holes. Install armature to moving part of gate. 1. Place template on gate and post surfaces as marked on template. 2a Attach armature holder to TJ bracket. 2. Mark holes and prepare them per template. Actual Size (2x) 2b Attach armature plate to armature holder.
Page 6
2c Install cover plate. Install magnet assembly to non-moving post. 3a Attach mounting bracket to post. a. Attach bracket with two screws through two slotted holes. b. Leave screws loose so that bracket can adjusted. Actual Size Actual Size (2x) 2d Attach Armature Assembly to moving part of gate.
Page 7
3c Align magnet to armature. 3e Fully attach bracket. a. Press magnet to fully engage with armature. a. Check bracket alignment with marks. b. Mark bracket location. b. Fully tighten two screws in slotted holes. c. Drill and tap four (4) remaining holes for #10-24 screws. d.
Wiring Installation Attach wiring per information shown. DC (+) Violet 24 Volt DC, Brown Power Input Black DC (-) DC (+) Violet 12 Volt DC, Power Input Brown DC (-) Black Blue Yellow DPS: 0.25A, 30VDC, Resistive Green Gray MBS: 1A, 30VDC, Resistive White Connect conduit to lock.
Need help?
Do you have a question about the M490G and is the answer not in the manual?