Chapter 1 Overview
1.6 Power Management for Power Synchronization
■
Powering off sequence for turning off power or power recovery
Figure 1.9 Power off using a power synchronized unit
UPS setting
2
UPS unit for
Server#0
An instruction is issued
to turn off the
ETERNUS DX/AF
when no AC output is
detected.
(0 Power failure occurred (commercial power is stopped))
1
Shutdown of all the servers
2
Shutdown of all the server UPS units
3
Issuance of command to turn off the ETERNUS DX/AF from the power synchronized unit
4
ETERNUS DX/AF shutdown
5
Shutdown of the ETERNUS DX/AF UPS unit
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)