  • Page 1 {InstallationInstructs}{Production}{Health Group}{Internal} KODAK CR 7400 Digital Radiography System Installation Guide...
  • Page 2 INSTALLATION INSTRUCTIONS Carestream Health, Inc. Dental Business 150 Verona St. Rochester, NY 14608 Exclusive manufacturer of Kodak dental systems. © Carestream Health, Inc., 2007 The Kodak trademark and trade dress are used under license from Kodak 6H4130_en September 2007 – 6H4130...
  • Page 3 Carestream Health, Inc. Use of Manual The Kodak CR 7400 digital radiography system is designed to meet international safety and performance standards. Personnel operating the unit must have a thorough understanding of the proper operation of the system. This manual has been prepared to aid medical and technical personnel to understand and operate the system.
  • Page 4: Table Of Contents

    Installing the Kodak CR 7400 driver for the WINDOWS Vista Operating System . . . Installing the Kodak CR 7400 driver for WINDOWS 2000 and WINDOW XP Operating Systems ............
  • Page 5: Safety

    Caution Caution The Kodak CR 7400 digital radiography unit is a CLASS 1 Laser product. • Do not remove the unit cover. • Cover removal should be done only by authorized service personnel. Laser Safety Instructions During normal operation, the unit should always be enclosed in its protective cover to prevent the surrounding area from being exposed to the laser.
  • Page 6 INSTALLATION INSTRUCTIONS September 2007 – 6H4130...
  • Page 7: Cr7400 System Requirements

    Section 2: CR7400 System Requirements The system requirements for the CR7400 System is as follows: • Intel pentium IV 3.2 GHZ or faster • I GB RAM • 80 GB hard drive • CD-ROM drive • Ethernet 10/100/1000 Network Card •...
  • Page 8 INSTALLATION INSTRUCTIONS September 2007 – 6H4130...
  • Page 9: Installing The User Interface Software Of The Kodak Cr 7400 System

    • WIBU-Key installation (Microsoft Windows 2000 and XP operating system users skip this step) • Continuation of installation [1] Insert the user interface software CD for the Kodak CR 7400 system into the computer disk drive. The installation begins automatically.
  • Page 10: Installing Microsoft.net

    [10] Uncheck Yes, I want to view the Readme text now, then click Finish. A successful installation message appears. [11] Click OK to complete the WIBU-KEY installation. [12] Click Next. The Kodak CR7400 Install Shield Wizard appears. [13] Click Continue. The Destination Folder screen appears. September 2007 – 6H4130...
  • Page 11 [14] To install the software and images in the C:\Program files\Kodak\KodakQC folder, click Next; to change the location of the program file or image folder click Change and enter the new destination. Note It is recommended that you install the software and images in the C:\Program files\Kodak\KodakQC folder.
  • Page 12: Installing The Kodak Cr 7400 Driver For The Windows Vista Operating System

    E:\Driver (where E: is the CD drive), and click Next. The driver software is installed. [7] When the installation is complete, click Close. This completes the software installation for the Kodak CR 7400 unit. Proceed to the KODAK CR 7400 System Setup.
  • Page 13: Installing The Kodak Cr 7400 Driver For Windows 2000 And Window Xp Operating Systems

    After you install the software, keep the user interface software CD-ROM in the computer disk drive and install the Kodak CR 7400 driver as described below: [1] Connect the power cable to the back of the Kodak CR 7400 unit. USB connection...
  • Page 14 INSTALLATION INSTRUCTIONS New Hardware Wizard software search screen [6] Select Install from a list or specific location and click Next. The following screen appears: Software search location screen [7] Indicate where to search for the software, usually E:\Driver\ (where E: is the CD drive), and click Next. When the hardware is found, the following screen appears: September 2007 –...
  • Page 15 Windows Logo warning [8] Click Continue Anyway. An installation complete screen appears. [9] Click Finish. This completes the software installation for the Kodak CR 7400 unit. Proceed to the KODAK CR 7400 System Setup. 6H4130 – September 2007...
  • Page 16 INSTALLATION INSTRUCTIONS September 2007 – 6H4130...
  • Page 17: Kodak Cr 7400 System Setup

    Section 4: KODAK CR 7400 System Setup During all phases of Kodak CR 7400 system setup, the unit must be turned on and the USB cable connected between the unit and the computer. Initial setup [1] Click on the Kodak Dental Software icon on the computer desktop.
  • Page 18 INSTALLATION INSTRUCTIONS The Technician (level 1) screen appears with the Anatomical tab open: Anatomical tab September 2007 – 6H4130...
  • Page 19: Selecting And Naming Rooms

    Selecting and Naming Rooms In the Room Configuration area, select which rooms (up to four rooms) you want to make available on the Main Screen. You may also change the names of the rooms. Room Configuration area of Anatomical tab [1] Select a room, then type over the existing name to change to the room name that you want.
  • Page 20: Selecting Intraoral And Extraoral Preferences

    INSTALLATION INSTRUCTIONS Selecting Intraoral and Extraoral Preferences [1] On the Main screen, click the Info/Setup button and log in as before. [2] Select the Setup tab. The Setup tab appears: Plate configuration area Setup tab [3] In the Plate Configuration area of the Setup tab, select the plates you want to make available to each room. Only the plates you select will appear on the Main Screen.
  • Page 21: Fine Tuning The Cr7400

    [9] Click OK to return to the Main Screen. Fine Tuning the CR7400 All Kodak CR 7400 systems pass calibration and tuning procedures before leaving the factory. Perform the following procedures in the clinic after installation to verify unit calibration.
  • Page 22: Intraoral Gain Verification

    INSTALLATION INSTRUCTIONS Intraoral Gain Verification [1] In the Acquisition window, set the button to Intraoral. [2] Select High Speed scanning mode and select holder size 0-2. [3] Type the x-ray setting used in your practice for adult patients. See “Table 1: Factory X-ray Parameters Used to Tune the CR7400 unit.”...
  • Page 23: Extraoral Gain Verification

    Extraoral Gain Verification [1] In the Acquisition window, set the button to Extraoral. [2] Select High Speed scanning mode. [3] Type the x-ray setting used in your practice for adult patients. See Table 1 for the factory setting for tuning a unit in production.
  • Page 24 INSTALLATION INSTRUCTIONS Image Viewer Window [10] Verify that the pixel value reaches 2900+100. [11] If the pixel value is within specifications, the procedure is complete. • Exit the image viewer. • Click the Setup tab and deselect Load image viewer after scan. •...
  • Page 25: Gain Tuning Procedure

    Gain Tuning Procedure [1] If the pixel value needs adjustment, proceed as follows: • To increase the pixel value, type a value in the Simulate PM Gain box lower than the value that appears in the Scanned PM Gain box. •...
  • Page 26 INSTALLATION INSTRUCTIONS September 2007 – 6H4130...
  • Page 27: Appendix A: Tuning Process Results Form

    Section 5: Appendix A: Tuning Process Results Form Table 1: Factory X-ray Parameters Used to Tune the CR7400 unit. IMAGING MODE X-RAY TUBE EXPOSURE TIME Intraoral 70kV, 8mA 12” 0.16s cephalometric 70kV, 10mA 150cm 0.17s Panoramic 70kV, 8mA 45.5cm Tuning Process Results Machine Serial Number: Software version: Date:...
  • Page 28 INSTALLATION INSTRUCTIONS Tuning Results Intraoral cephalometric Extraoral Pixel value Required Measured Required Measured Required Measured Required 2900±100 2900±100 2900±100 PM gain set at >40 >40 >40 the end of tuning process September 2007 – 6H4130...

Table of Contents