2. SYSTEM CONFIGURATION
2.2.3

Operating environment of the configuration software (parameter setting tool)

This section describes the operating environment when setting DN91 parameters with the
configuration software.
The configuration software is a peripheral device which installs the following configuration
software in a personal computer to allocate communication data for each slave station to the
DeviceNet master station.
(1) Configuration Software
SyCon Ver. 2.0.6.2 or later (Include DLL file Ver. 2.5.0.1 or later.)
(2) Operating Environment of the Configuration Software
The operating environment is shown below.
Item
Personal computer
CPU
OS
Free disk space
RAM
Display resolution
External storage
(3) RS-232C Cross-cable
The wiring connections of the RS-232C cross-cable which links the PC/AT-compatible
personal computer and DN91 are shown below.
A(1S)D53DN15Dsub
female connector
(9 pin)
Signal
Pin
Name
Number
1
RD
2
SD
3
DTR
4
SG
5
6
RS
7
CS
8
9
Shielded cable is recommended.
Connection of
Table 2.2 Operating Environment
PC/AT compatible personal computer
Intel 486 processor, or above
Windows95, WindowsNT3.51, WindowsNT4.0 *
10 Mbyte min.
16 Mbyte min.
800 x 600 dot, min.
CD-ROM drive (for installation only)
*: Registered trademark of Microsoft Corporation.
PC/AT-compatible
PC Dsub female
connectors
(9 pin)
Pin
Number
1
2
3
4
5
6
7
8
9
not connected
is recommended to eliminate directionality.
2
5
MELSEC-A
Environment
Signal
Name
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI

Advertisement