SUN2000-(33KTL, 40KTL) User Manual Issue Date 2015-12-01 HUAWEI TECHNOLOGIES CO., LTD.
Page 2
Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
Do not remove the anti-dismantle label on the SUN2000 enclosure because it is the basis for product warranty. Installation Read this document before installation. Huawei shall not be liable for any consequence caused by violation of the regulations specified in this document. ...
2 Overview Overview 2.1 Introduction Function The SUN2000-33KTL/40KTL is a three-phase grid-tied PV string inverter that converts the DC power generated by PV strings into AC power and feeds the power into the power grid. Models Figure 2-1 shows a model number of the SUN2000-33KTL/40KTL, using SUN2000-33KTL as an example.
Page 11
(C) ACDU (D) Isolation transformer (E) Power grid Supported Power Grids The SUN2000-33KTL supports the power grid modes TN-S, TN-C, TN-C-S, and TT, as shown in Figure 2-3. The SUN2000-40KTL only supports the power grid mode IT, as shown Figure 2-4.
Negative DC input terminal (-) Six routes Antenna (ANT) Reserved WiFi port RS485 port (COM2) 2.3 Label Conventions This section describes the symbols and nameplate on the SUN2000-33KTL/40KTL. Symbols Table 2-3 describes all symbols on the SUN2000-33KTL/40KTL. Table 2-3 Symbols Symbol...
Page 17
SUN2000 manufacture information. Nameplate The SUN2000-33KTL/40KTL is labeled with a nameplate that contains the model information, technical specifications, and compliance symbols. If the SUN2000 only uses RS485 for communication, the value of Communication on the nameplate is RS485, as shown Figure 2-9.
This section describes the SUN2000 working process. Circuit Diagrams The SUN2000-33KTL/40KTL receives inputs from six PV strings. Then the inputs are grouped into three MPPT routes inside the SUN2000 to track the maximum power point of the PV strings. The DC power is then converted into three-phase AC power through a converter circuit.
Page 36
Figure 4-9 Dimensions of the rear panel (unit: mm) Context When installing the SUN2000-33KTL, you can use the expansion bolts delivered with the SUN2000 to install the rear panel. When installing the SUN2000-40KTL, you need to prepare the expansion bolts. M12x60 stainless expansion bolts are recommended.
6–2 AWG) (L1, L2, and The customer needs to prepare OT terminals. The SUN2000-33KTL requires M6 OT terminals and a cable with the maximum cross-sectional area of 25 mm can be connected. The SUN2000-40KTL requires M8 OT terminals and a cable with the maximum cross-sectional area of 35 mm can be connected.
Page 55
Step 6 Route the AC output power cable into the locking cap and the AC OUTPUT connector at the inverter bottom. Step 7 Connect the wires of the AC output cable for the SUN2000-33KTL to L1, L2, L3, and N on the AC terminal block, as shown in Figure 5-9.
5.5.1 Communication Mode Description RS485 The SUN2000-33KTL/40KTL can connect to the SmartLogger over RS485 or to a PC through the SmartLogger to implement communication. You can use the SmartLogger LCD, embedded WebUI, or the network management software (such as the NetEco) on the PC to query information about the SUN2000-33KTL/40KTL, such as electric energy yield, alarms, and running status.
SmartLogger cannot exceed 1000 meters. If multiple SUN2000-33KTL/40KTLs need to communicate with one another and are connected to a PC over the SmartLogger, a maximum of three daisy chains can be configured to support up to 80 devices. It is recommended that the number of devices on each daisy chain be less than 30.
Page 87
SUN2000 to OFF, wait 5 minutes, SUN2000. and flip the DC SWITCH to ON. Check whether the fault is rectified. If the fault persists, contact Huawei technical support. 1. If the fault is caused by a short Internal Minor ...
Page 90
48 A Power factor 0.8 lagging, 0.8 leading Max. total harmonic < 3% distortion Note a: The maximum output power of the SUN2000-33KTL varies depending on the chosen grid code, as described in A Power Grid Codes. Protection Technical SUN2000-33KTL...
A Power Grid Codes Power Grid Codes Grid codes are subject to change. The listed codes are for your reference only. Table A-1 lists the power grid standard codes which the SUN2000-33KTL supports. Table A-1 Power grid codes (SUN2000-33KTL) Power Grid Code Description...