Installation; Led Indications - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
System Hardware Manual
DC Voltage (On hook) (-28Vdc)
Feeding Polarity Reverse Ability
Ring Generator (75Vrms, 16Hz/20Hz/25Hz selectable by CM82-04-02)
Caller ID Sending Ability
Message Wait Lamping Ability (110V DC)
Cable length = 600ohms (including the SLT). Approximately 1Km
The CD-16LCAH consumes sixteen ports ranging between ports
001~256. The connectors each provide connection to four analog
station ports. The CNx connectors are not polarity sensitive.
Table 4-30 CD-4LCA/CD-8LCA Maximum Upgrade Capacities
19"
SLIU
Chassis
with CPU
CD-16LCAH
4.5.2

Installation

Install the CD-16LCAH blade into any available universal slot.
4.5.3

LED Indications

LED indications for the CD-16LCAHare listed in
16LCAH LED
function and LED and Operational status.
19" Chassis
without CPU
5
6
When connecting a fax machine or analog
modem, make sure to set Program 15-03-03 to
1 (special terminal) to avoid communication
problems.
The SLIU and SLIDB are categorized as
TNV2. With this designation, off-premise
wiring is not acceptable. Any cabling to the
SLIU blade must be within the building – no
outside cabling is permitted.
Branch connection is not acceptable.
Indications. Each LED is listed with its associated
Issue 7.0
19" Chassis
Networked
x4
Chassis
23
32
Table 4-31 CD-
4 - 63

Advertisement

Table of Contents
loading