Chapter 6
Troubleshooting
Event
Fault/Alarm Text
No.
224
Port 4 Comm Loss
225
Port 5 Comm Loss
226
Port 6 Comm Loss
227
Port 7 Comm Loss
228
Port 8 Comm Loss
229
Port 9 Comm Loss
230
Port10 Comm Loss
231
Port11 Comm Loss
232
Port12 Comm Loss
233
Port13 Comm Loss
234
Port14 Comm Loss
244
Port 4 Cfg
245
Port 5 Cfg
246
Port 6 Cfg
247
Port 7 Cfg
248
Port 8 Cfg
249
Port 9 Cfg
250
Port 10 Cfg
251
Port 11 Cfg
252
Port 12 Cfg
253
Port 13 Cfg
254
Port 14 Cfg
264
Port 4 Checksum
265
Port 5 Checksum
266
Port 6 Checksum
267
Port 7 Checksum
268
Port 8 Checksum
269
Port 9 Checksum
270
Port10 Checksum
271
Port11 Checksum
272
Port12 Checksum
273
Port13 Checksum
274
Port14 Checksum
281
Enet Checksum
282
DLX Checksum
290
Prev Maint Reset
291
HSFan Life
292
InFan Life
293
MtrBrng Life
294
MtrBrng Lube
295
MachBrng Life
296
MachBrng Lube
307
Port7InvalidCard
308
Port8InvalidCard
310
Regeneration OK
315
Excess Psn Err
318
OutCurShare PhU
319
OutCurShare PhV
320
OutCurShare PhW
318
Type
Fault
Configuration
Action
Parameter
Resettable Fault
Coast
Alarm 2
Resettable Fault
Coast
Resettable Fault
Coast
Resettable Fault
Coast
Alarm 1
Configurable
493
[HSFan EventActn]
Configurable
500
[InFan EventActn]
Configurable
506
[MtrBrngEventActn]
Configurable
510
[MtrLubeEventActn]
Configurable
515
[MtrBrngEventActn]
Configurable
519
[MchLubeEventActn]
Non-Reset Fault
Coast
Non-Reset Fault
Coast
Resettable Fault
Coast
Configurable
Configured with Logix
controller.
Alarm 1
Rockwell Automation Publication 750-PM001N-EN-P - February 2017
Auto
Description/Action(s)
Reset
The device at the port has stopped communicating with the main
control board.
Verify that the device is present and functional.
Verify network connections.
Verify options that are installed in ports 4...8 are seated in the port
and secured with mounting screws.
The main control board does not have the correct option in the port.
Option may not be compatible with product or MCB firmware must be
updated to support it. Option may have to be moved or removed,
accept option configuration change.
An option module storage checksum failed.
Option data has been set to default values.
EtherNet/IP storage checksum failed. Data set to default values.
DeviceLogix storage checksum failed. Data set to default values.
Predictive maintenance function has reset an elapsed life parameter.
Predictive maintenance function has reached the event level. Perform
maintenance.
Option not valid in that port. Remove option module.
The drive has detected that the 'Regeneration OK' input has transition
to an 'inactive' state.
The absolute maximum Position Error value has been exceeded.
There is output current sharing imbalance between parallel inverters
in the phase indicated that is greater than 15 % of the inverter rated
current.