Data And Control Interface Contact Assignments; Terminator Resistors - NEC FD1165 Maintenance Manual

Flexible
Hide thumbs Also See for FD1165:
Table of Contents

Advertisement

Table 2-3
2.6

TERMINATOR RESISTORS

The Model FD1165 is shipped with terminator resistor arrays
RN1 and RN2 installed as shown in Figure 2-11.
move these resistors when only a single disk drive is used
in a system.
Do not remove these resistors when two or more
disk drives are connected in parallel to a single controller
(see Figure 2-12A) .
are connected in series to a single controller, remove RN1
and RN2 from each disk drive except
circuit (see Figure 2-12B).
Data and Control Interface Contact
Assignments
However, when two or more disk drives
2 - 9
Do not re­
the last one in the