6 Installation
6.4

Electrical connections

Fig.35
Remove terminal cover
42
See
Electrical supply, page 25 for details of the electrical supply.
Warning
Check that the total nominal consumption of the accessories con­
nected to the appliance is less than 1 amp. If it is higher, a relay
must be installed between the accessories and the electronic
board.
6.4.1
1
2
3
4
5
6
H
7
8
9
10
1
2
G
3
4
5
Important
When fitting Low Voltage Controls remove the yellow link wire
from the Mains Terminal Block M1.
Note
Consideration must be given to Health and Safety Document 635
(The Electricity at Work Regulations, 1989).
1. Remove the front panel.
See
Specific maintenance instructions, page 55 to remove the front
panel.
2. Hinge down the control box and unclip the terminal block cover.
3. Slacken both gland nuts in the bottom of the boiler lower panel and
insert the mains cable and the external control system cable through
them.
4. Leave sufficient slack in the cables to allow the control box to be
hinged fully open. Tighten both gland nuts.

Making the electrical connection

PN-0000395
7678846 - A - 22052017

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the assure combi 25 and is the answer not in the manual?

Questions and answers

Stephanie
March 7, 2025

What is the GC number

This manual is also suitable for:

Assure combi 30Assure system 18Assure system 15

Table of Contents

Save PDF