MAINTENANCE
2.
DO NOT file the 'gullet' (radius) of the tooth with the flat file. The radius
must remain. A sharp corner will lead to a crack and blade failure.
If an electric grinder is used, use care not to overheat teeth, do not
allow tips/tooth to glow red or turn blue. DO NOT place blade in cool-
ing water. This will change the temper of the blade and could result
in blade failure.
3.
After sharpening teeth, check
each tooth radius for evidence
of a square (sharp) corner. Use
the round (rat tail) file to renew
the radius.
Edger Blade Replacement
Level 1.
Parts Required: Blade, new split pin
Note: Replace blade when it is bent, damaged, or worn shorter than
152.4 mm (6 in.).
1.
Remove split pin (A).
2.
Align hole in inner blade
adapter (B) with notch in gear
housing, and insert locking tool
(G) to prevent PTO shaft (C)
from rotating.
3.
Remove L.H. blade nut (D) by
turning clockwise. Remove
outer blade adapter (E), and
blade (F).
4.
Install and center blade (F) on
inner blade adapter (B).
44
PAS-225 VP
G
X7732274200
© 5/2017 ECHO Inc.
Need help?
Do you have a question about the PAS-225 and is the answer not in the manual?
Questions and answers