Edger Blade Replacement

Level 1.
Parts Required: Blade, new split pin
Note: Replace blade when it is bent, damaged, or worn shorter than
152.4 mm (6 in.).
1.
Remove split pin (A).
2.
Align hole in inner blade
adapter (B) with notch in gear
housing, and insert locking tool
(G) to prevent PTO shaft (C)
from rotating.
3.
Remove L.H. blade nut (D) by
turning clockwise. Remove
outer blade adapter (E), and
blade (F).
4.
Install and center blade (F) on
inner blade adapter (B).