Chapter 14 Error Codes - Delta MS300 Series User Manual

Standard compact drive
Hide thumbs Also See for MS300 Series:
Table of Contents

Advertisement

CALL NOW 800-985-6929
Model name of digital keypad: KPMS-LE01
*Follow the settings of Pr. 06-17 ~ Pr. 06-22 and Pr. 14-70 ~ Pr. 14-73
ID No.
Display
1
2
3
CALL NOW 800-985-6929
http://www.deltaacdrives.com

Chapter 14 Error Codes

Over-current during acceleration (Output current exceeds triple rated current
during acceleration.)
Corrective Actions
 Short-circuit at motor output: Check for possible poor insulation at the
output.
 Acceleration time too short: Increase acceleration time.
 AC motor drive output power is too small: Replace the AC motor drive
with higher power model.
Over-current during deceleration (Output current exceeds triple rated current
during deceleration.)
Corrective Actions
 Short-circuit at motor output: Check for possible poor insulation at the
output.
 Acceleration time too short: Increase acceleration time.
 AC motor drive output power is too small: Replace the AC motor drive
with higher power model.
Over-current during steady state operation (Output current exceeds triple
rated current during constant speed.)
Corrective Actions
 Short-circuit at motor output: Check for possible poor insulation at the
output.
 Acceleration time too short: Increase acceleration time.
 AC motor drive output power is too small: Replace the AC motor drive
with higher power model.
http://www.deltaacdrives.com
Chapter 14 Error CodesMS300
Descriptions
14-1
Email: info@deltaacdrives.com
Email: info@deltaacdrives.com

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS300 Series and is the answer not in the manual?

Questions and answers

matt ferree
April 8, 2025

how do i get to the paramaters i need

1 comments:
Mr. Anderson
April 9, 2025

To access the parameters for the Delta MS300 Series:

1. Set parameter Pr.13-00 to the desired application type (e.g., 4 for Pump, 5 for Conveyor, etc.).
2. The keypad will display a label based on the selected application (e.g., PUMP, CnYr).
3. For User Defined applications, set Pr.13-00 = 1.
4. Then set parameters Pr.13-01 to Pr.13-50 as needed.
5. Press the MODE button to switch to the APP page.
6. Press ENTER to go to the USEr page to view and edit the defined parameters.
7. Use the up, down, left keys to adjust values.
8. Press ENTER again to confirm and display the user-defined parameters.

This answer is automatically generated