Chapter 8 Optional Cards MS300
Environment
Noise immunity
Operation / Storage
Shock / Vibration resistance
Communication Parameters for VFD-MS300 Connected to EtherNet
When VFD-MS300 links to EtherNet, please set up the communication parameters based on the table below.
The EtherNet master will be able to read/write frequency command word and operation command word to
VFD-MS300 after the communication parameters are set.
Parameter
00-20
00-21
09-30
09-75
09-76
09-77
09-78
09-79
09-80
09-81
09-82
09-83
09-84
09-85
09-86
09-87
Basic Registers
BR#
R/W
#0
R
#1
R
#2
R
#11
R/W
#13
R/W
CALL NOW 800-985-6929
http://www.deltaacdrives.com
ESD (IEC 61800-5-1, IEC 6100-4-2)
EFT (IEC 61800-5-1, IEC 6100-4-4)
Surge Test (IEC 61800-5-1, IEC 6100-4-5)
Conducted Susceptibility Test (IEC 61800-5-1, IEC 6100-4-6)
Operation
Storage
International standards
IEC 61800-5-1, IEC 60068-2-6 / IEC 61800-5-1, IEC 60068-2-27
Function
Current Set Value
Setting for source of
frequency command
Setting for source of
operation command
Decoding method for
communication
IP setting
IP address -1
IP address -2
IP address -3
IP address -4
Netmask -1
Netmask -2
Netmask -3
Netmask -4
Default gateway -1
Default gateway -2
Default gateway -3
Default gateway -4
Content
Model name
Set up by the system. The model code of CMM-MOD01=H'0203
Displaying the current firmware version in hex, e.g. 0100h indicates
Firmware version
firmware version V1.00
Displaying the data in decimal form. 10,000s digit and 1,000s digit
Release date of the
are for "month"; 100s digit and 10s digit are for "day".
version
For 1 digit: 0 = morning; 1 = afternoon
MODBUS Timeout
Pre-defined setting: 500 (ms)
Keep Alive Time
Pre-defined setting: 30 (s)
http://www.deltaacdrives.com
:
-10°C ~ 50°C (temperature),90% (humidity)
:
-25°C ~ 70°C (temperature),95% (humidity)
:
The frequency command is controlled by
8
communication card
The operation command is controlled by
5
communication card
0
Decoding method for Delta AC motor drive
0
Static IP(0) / Dynamic distribution IP(1)
192
IP address 192.168.1.5
168
IP address 192.168.1.5
1
IP address 192.168.1.5
5
IP address 192.168.1.5
255
Netmask 255.255.255.0
255
Netmask 255.255.255.0
255
Netmask 255.255.255.0
0
Netmask 255.255.255.0
192
Default gateway 192.168.1.1
168
Default gateway 192.168.1.1
1
Default gateway 192.168.1.1
1
Default gateway 192.168.1.1
8-8
Email: info@deltaacdrives.com
Definition of Parameter Values
Set Value
Email: info@deltaacdrives.com
Need help?
Do you have a question about the MS300 Series and is the answer not in the manual?
Questions and answers
how do i get to the paramaters i need
To access the parameters for the Delta MS300 Series:
1. Set parameter Pr.13-00 to the desired application type (e.g., 4 for Pump, 5 for Conveyor, etc.).
2. The keypad will display a label based on the selected application (e.g., PUMP, CnYr).
3. For User Defined applications, set Pr.13-00 = 1.
4. Then set parameters Pr.13-01 to Pr.13-50 as needed.
5. Press the MODE button to switch to the APP page.
6. Press ENTER to go to the USEr page to view and edit the defined parameters.
7. Use the up, down, left keys to adjust values.
8. Press ENTER again to confirm and display the user-defined parameters.