Programming The Simotion Application; Using Tags - Siemens SIMOTION SCOUT Configuration Manual

Motion control
Table of Contents

Advertisement

Configuring/parameterizing

6.6 Programming the SIMOTION application

3. Click the Return control priority button to return the control priority of the control panel.
4. On the menu bar, select Project > Disconnect from target system to switch to offline mode.
Result
The axis can be traversed. Axis configuration is complete.
Potential problems
The axis cannot be traversed.
If the axis cannot be traversed using the axis control panel, test to see if you can traverse the
drive using the drive control panel.
● If you cannot traverse the drive using the drive control panel, there is a problem with the
drive.
● If you can traverse the drive with the drive control panel, there is a communication problem.
Check the drive.
6.6
Programming the SIMOTION application
6.6.1

Using tags

Variable types
Variables are used to structure programs. They are wild cards in a program and can assume
values.
110
SIMOTION SCOUT
Configuration Manual, 11/2016