Hide thumbs Also See for OriLink:

Advertisement

MANUAL / BRUKSANVISNING / GUIDE D'INSTRUCTIONS / BEDIENUNGSANLEITUNG
OriLink®
Monitoring System
Keypad module, 23401
(Covers KP with PCB version 203 02 65 D and 203 02 90A, some features may be missing in earlier versions)
English Manual for KP-module 23401, Rev ERC0, 170616

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OriLink and is the answer not in the manual?

Questions and answers

Summary of Contents for Orion OriLink

  • Page 1 MANUAL / BRUKSANVISNING / GUIDE D’INSTRUCTIONS / BEDIENUNGSANLEITUNG OriLink® Monitoring System Keypad module, 23401 (Covers KP with PCB version 203 02 65 D and 203 02 90A, some features may be missing in earlier versions) English Manual for KP-module 23401, Rev ERC0, 170616...
  • Page 2: Table Of Contents

    Table of Contents 1. INTRODUCTION ................................3 2. MECHANICAL INSTALLATION ..........................3 3. ELECTRIC INSTALLATION ............................3 4. CONFIGURATION ................................4 4.1..........................5 HECK BEFORE CONFIGURATION 4.2..........................5 DDRESSING THE NEW MODULE 4.3. SET-UP ................................ 5 MODE 4.4. [KP//A ] .........................
  • Page 3: Introduction

    Introduction The KeyPad is the tool that is used to configure an OriLink® monitoring system, as well as initiate dispenses, stop dispenses and check previous dispenses. NOTE! The Orilink® installation manual should be available when installing and configuring a KeyPad.
  • Page 4 4(10)
  • Page 5: Configuration

    Testing modules. NOTE! Do not forget to check and adjust the termination and BIAS according to the Orilink® Manual. 4.2. Addressing the new module A new module has no address on delivery. To address a new module or one with an unknown address you press and hold the RESET-button for 5 seconds.
  • Page 6: Recommendation For Setting Addresses

    Readers can be used in a system without a PC but on older systems the baud rate and the functionality can only be set by using a PC with OriLink® WinTools professional installed. For newer systems or recently updated systems it is possible to set the baud rate from a keypad but to set other functionalities a PC with OriLink®...
  • Page 7: Using A Keypad Module

    The set baud rate function from a keypad only exists if a flash chip is used (Yellow label), see chapter “3. Electric installations”, and the chip software version is KP10010RC2 or later. Enter menu [KP//Address] by pressing ENTER. Scroll to menu Baud: by pressing  or . Press ENTER to get the cursor.
  • Page 8: Installing A Serial Port Kit (23 415)

    After the hardware installation the keypad has to be set to handle the serial port properly. This can only be done from a PC running OriLink® WinTools professional. After the setup is done there is no need for a PC to use the serial port.
  • Page 9: Fast Menu Codes

    Fast Menu Codes With a PC, the OriLink® WinTools software and a SIO the quick menu that appear when you press “?” can be adjusted. Typing a menu name, the module address and then a code can do this. Password can be used if desired.
  • Page 10: Technical Specification

    Technical specification Printed circuit board Net ports: 2 pieces of OriLink® ports (E) for data- communication. Connector: 1 piece of serial port connector (G). Socket: 1 piece of 16-pin DIL-socket (H) for a MAX232CPE serial port driver. LCD display: 2x16 signs with backlight.